Internet Engineering Task Force (IETF) C. Lever Request for Comments: 8797 Oracle Updates: 8166 June 2020 Category: Standards Track ISSN: 2070-1721

Remote Direct Memory Access - Connection Manager (RDMA-CM) Private Data

                    for RPC-over-RDMA Version 1

Abstract

 This document specifies the format of Remote Direct Memory Access -
 Connection Manager (RDMA-CM) Private Data exchanged between RPC-over-
 RDMA version 1 peers as part of establishing a connection.  The
 addition of the Private Data payload specified in this document is an
 optional extension that does not alter the RPC-over-RDMA version 1
 protocol.  This document updates RFC 8166.

Status of This Memo

 This is an Internet Standards Track document.
 This document is a product of the Internet Engineering Task Force
 (IETF).  It represents the consensus of the IETF community.  It has
 received public review and has been approved for publication by the
 Internet Engineering Steering Group (IESG).  Further information on
 Internet Standards is available in Section 2 of RFC 7841.
 Information about the current status of this document, any errata,
 and how to provide feedback on it may be obtained at
 https://www.rfc-editor.org/info/rfc8797.

Copyright Notice

 Copyright (c) 2020 IETF Trust and the persons identified as the
 document authors.  All rights reserved.
 This document is subject to BCP 78 and the IETF Trust's Legal
 Provisions Relating to IETF Documents
 (https://trustee.ietf.org/license-info) in effect on the date of
 publication of this document.  Please review these documents
 carefully, as they describe your rights and restrictions with respect
 to this document.  Code Components extracted from this document must
 include Simplified BSD License text as described in Section 4.e of
 the Trust Legal Provisions and are provided without warranty as
 described in the Simplified BSD License.

Table of Contents

 1.  Introduction
 2.  Requirements Language
 3.  Advertised Transport Properties
   3.1.  Inline Threshold Size
   3.2.  Remote Invalidation
 4.  Private Data Message Format
   4.1.  Using the R Field
   4.2.  Send and Receive Size Values
 5.  Interoperability Considerations
   5.1.  Interoperability with RPC-over-RDMA Version 1
         Implementations
   5.2.  Interoperability amongst RDMA Transports
 6.  Updating the Message Format
 7.  Security Considerations
 8.  IANA Considerations
   8.1.  Guidance for Designated Experts
 9.  References
   9.1.  Normative References
   9.2.  Informative References
 Acknowledgments
 Author's Address

1. Introduction

 The RPC-over-RDMA version 1 transport protocol [RFC8166] enables
 payload data transfer using Remote Direct Memory Access (RDMA) for
 upper-layer protocols based on Remote Procedure Calls (RPCs)
 [RFC5531].  The terms "Remote Direct Memory Access" (RDMA) and
 "Direct Data Placement" (DDP) are introduced in [RFC5040].
 The two most immediate shortcomings of RPC-over-RDMA version 1 are as
 follows:
 1.  Setting up an RDMA data transfer (via RDMA Read or Write) can be
     costly.  The small default size of messages transmitted using
     RDMA Send forces the use of RDMA Read or Write operations even
     for relatively small messages and data payloads.
     The original specification of RPC-over-RDMA version 1 provided an
     out-of-band protocol for passing inline threshold values between
     connected peers [RFC5666].  However, [RFC8166] eliminated support
     for this protocol, making it unavailable for this purpose.
 2.  Unlike most other contemporary RDMA-enabled storage protocols,
     there is no facility in RPC-over-RDMA version 1 that enables the
     use of remote invalidation [RFC5042].
 Each RPC-over-RDMA version 1 Transport Header follows the External
 Data Representation (XDR) definition [RFC4506] specified in
 [RFC8166].  However, RPC-over-RDMA version 1 has no means of
 extending this definition in such a way that interoperability with
 existing implementations is preserved.  As a result, an out-of-band
 mechanism is needed to help relieve these constraints for existing
 RPC-over-RDMA version 1 implementations.
 This document specifies a simple, non-XDR-based message format
 designed to be passed between RPC-over-RDMA version 1 peers at the
 time each RDMA transport connection is first established.  The
 mechanism assumes that the underlying RDMA transport has a Private
 Data field that is passed between peers at connection time, such as
 is present in the Marker PDU Aligned Framing (MPA) protocol
 (described in Section 7.1 of [RFC5044] and extended in [RFC6581]) or
 the InfiniBand Connection Manager [IBA].
 To enable current RPC-over-RDMA version 1 implementations to
 interoperate with implementations that support the message format
 described in this document, implementation of the Private Data
 exchange is OPTIONAL.  When Private Data has been successfully
 exchanged, peers may choose to perform extended RDMA semantics.
 However, this exchange does not alter the XDR definition specified in
 [RFC8166].
 The message format is intended to be further extensible within the
 normal scope of such IETF work (see Section 6 for further details).
 Section 8 of this document defines an IANA registry for this purpose.
 In addition, interoperation between implementations of RPC-over-RDMA
 version 1 that present this message format to peers and those that do
 not recognize this message format is guaranteed.

2. Requirements Language

 The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
 "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
 "OPTIONAL" in this document are to be interpreted as described in
 BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all
 capitals, as shown here.

3. Advertised Transport Properties

3.1. Inline Threshold Size

 Section 3.3.2 of [RFC8166] defines the term "inline threshold".  An
 inline threshold is the maximum number of bytes that can be
 transmitted using one RDMA Send and one RDMA Receive.  There are a
 pair of inline thresholds for a connection: a client-to-server
 threshold and a server-to-client threshold.
 If an incoming RDMA message exceeds the size of a receiver's inline
 threshold, the Receive operation fails and the RDMA provider
 typically terminates the connection.  To convey an RPC message larger
 than the receiver's inline threshold without risking receive failure,
 a sender must use explicit RDMA data transfer operations, which are
 more expensive than an RDMA Send.  See Sections 3.3 and 3.5 of
 [RFC8166] for a complete discussion.
 The default value of inline thresholds for RPC-over-RDMA version 1
 connections is 1024 bytes (as defined in Section 3.3.3 of [RFC8166]).
 This value is adequate for nearly all NFS version 3 procedures.
 NFS version 4 COMPOUND operations [RFC7530] are larger on average
 than NFS version 3 procedures [RFC1813], forcing clients to use
 explicit RDMA operations for frequently issued requests such as
 LOOKUP and GETATTR.  The use of RPCSEC_GSS security also increases
 the average size of RPC messages, due to the larger size of
 RPCSEC_GSS credential material included in RPC headers [RFC7861].
 If a sender and receiver could somehow agree on larger inline
 thresholds, frequently used RPC transactions avoid the cost of
 explicit RDMA operations.

3.2. Remote Invalidation

 After an RDMA data transfer operation completes, an RDMA consumer can
 request that its peer's RDMA Network Interface Card (RNIC) invalidate
 the Steering Tag (STag) associated with the data transfer [RFC5042].
 An RDMA consumer requests remote invalidation by posting an RDMA Send
 with Invalidate operation in place of an RDMA Send operation.  Each
 RDMA Send with Invalidate carries one STag to invalidate.  The
 receiver of an RDMA Send with Invalidate performs the requested
 invalidation and then reports that invalidation as part of the
 completion of a waiting Receive operation.
 If both peers support remote invalidation, an RPC-over-RDMA responder
 might use remote invalidation when replying to an RPC request that
 provided chunks.  Because one of the chunks has already been
 invalidated, finalizing the results of the RPC is made simpler and
 faster.
 However, there are some important caveats that contraindicate the
 blanket use of remote invalidation:
  • Remote invalidation is not supported by all RNICs.
  • Not all RPC-over-RDMA responder implementations can generate RDMA

Send with Invalidate operations.

  • Not all RPC-over-RDMA requester implementations can recognize when

remote invalidation has occurred.

  • On one connection in different RPC-over-RDMA transactions, or in a

single RPC-over-RDMA transaction, an RPC-over-RDMA requester can

    expose a mixture of STags that may be invalidated remotely and
    some that must not be.  No indication is provided at the RDMA
    layer as to which is which.
 A responder therefore must not employ remote invalidation unless it
 is aware of support for it in its own RDMA stack, and on the
 requester.  And, without altering the XDR structure of RPC-over-RDMA
 version 1 messages, it is not possible to support remote invalidation
 with requesters that include an STag that must not be invalidated
 remotely in an RPC with STags that may be invalidated.  Likewise, it
 is not possible to support remote invalidation with requesters that
 mix RPCs with STags that may be invalidated with RPCs with STags that
 must not be invalidated on the same connection.
 There are some NFS/RDMA client implementations whose STags are always
 safe to invalidate remotely.  For such clients, indicating to the
 responder that remote invalidation is always safe can enable such
 invalidation without the need for additional protocol elements to be
 defined.

4. Private Data Message Format

 With an InfiniBand lower layer, for example, RDMA connection setup
 uses a Connection Manager (CM) when establishing a Reliable
 Connection [IBA].  When an RPC-over-RDMA version 1 transport
 connection is established, the client (which actively establishes
 connections) and the server (which passively accepts connections)
 populate the CM Private Data field exchanged as part of CM connection
 establishment.
 The transport properties exchanged via this mechanism are fixed for
 the life of the connection.  Each new connection presents an
 opportunity for a fresh exchange.  An implementation of the extension
 described in this document MUST be prepared for the settings to
 change upon a reconnection.
 For RPC-over-RDMA version 1, the CM Private Data field is formatted
 as described below.  RPC clients and servers use the same format.  If
 the capacity of the Private Data field is too small to contain this
 message format or the underlying RDMA transport is not managed by a
 CM, the CM Private Data field cannot be used on behalf of RPC-over-
 RDMA version 1.
 The first eight octets of the CM Private Data field are to be
 formatted as follows:
   0                   1                   2                   3
   0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
  |                       Format Identifier                       |
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
  |    Version    |  Reserved   |R|   Send Size   | Receive Size  |
  +-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+-+
 Format Identifier:  This field contains a fixed 32-bit value that
    identifies the content of the Private Data field as an RPC-over-
    RDMA version 1 CM Private Data message.  In RPC-over-RDMA
    version 1 Private Data, the value of this field is always
    0xf6ab0e18, in network byte order.  The use of this field is
    further expanded upon in Section 5.2.
 Version:  This 8-bit field contains a message format version number.
    The value "1" in this field indicates that exactly eight octets
    are present, that they appear in the order described in this
    section, and that each has the meaning defined in this section.
    Further considerations about the use of this field are discussed
    in Section 6.
 Reserved:  This 7-bit field is unused.  Senders MUST set these bits
    to zero, and receivers MUST ignore their value.
 R:  This 1-bit field indicates that the sender supports remote
    invalidation.  The field is set and interpreted as described in
    Section 4.1.
 Send Size:  This 8-bit field contains an encoded value corresponding
    to the maximum number of bytes this peer is prepared to transmit
    in a single RDMA Send on this connection.  The value is encoded as
    described in Section 4.2.
 Receive Size:  This 8-bit field contains an encoded value
    corresponding to the maximum number of bytes this peer is prepared
    to receive with a single RDMA Receive on this connection.  The
    value is encoded as described in Section 4.2.

4.1. Using the R Field

 The R field indicates limited support for remote invalidation as
 described in Section 3.2.  When both connection peers have set this
 bit flag in their CM Private Data, the responder MAY use RDMA Send
 with Invalidate operations when transmitting RPC Replies.  Each RDMA
 Send with Invalidate MUST invalidate an STag associated only with the
 Transaction ID (XID) in the rdma_xid field of the RPC-over-RDMA
 Transport Header it carries.
 When either peer on a connection clears this flag, the responder MUST
 use only RDMA Send when transmitting RPC Replies.

4.2. Send and Receive Size Values

 Inline threshold sizes from 1024 to 262144 octets can be represented
 in the Send Size and Receive Size fields.  The inline threshold
 values provide a pair of 1024-octet-aligned maximum message lengths
 that guarantee that Send and Receive operations do not fail due to
 length errors.
 The minimum inline threshold for RPC-over-RDMA version 1 is 1024
 octets (see Section 3.3.3 of [RFC8166]).  The values in the Send Size
 and Receive Size fields represent the unsigned number of additional
 kilo-octets of length beyond the first 1024 octets.  Thus, a sender
 computes the encoded value by dividing its actual buffer size, in
 octets, by 1024 and subtracting one from the result.  A receiver
 decodes an incoming Size value by performing the inverse set of
 operations: it adds one to the encoded value and then multiplies that
 result by 1024.
 The client uses the smaller of its own send size and the server's
 reported receive size as the client-to-server inline threshold.  The
 server uses the smaller of its own send size and the client's
 reported receive size as the server-to-client inline threshold.

5. Interoperability Considerations

 The extension described in this document is designed to allow RPC-
 over-RDMA version implementations that use CM Private Data to
 interoperate fully with RPC-over-RDMA version 1 implementations that
 do not exchange this information.  Implementations that use this
 extension must also interoperate fully with RDMA implementations that
 use CM Private Data for other purposes.  Realizing these goals
 requires that implementations of this extension follow the practices
 described in the rest of this section.

5.1. Interoperability with RPC-over-RDMA Version 1 Implementations

 When a peer does not receive a CM Private Data message that conforms
 to Section 4, it needs to act as if the remote peer supports only the
 default RPC-over-RDMA version 1 settings, as defined in [RFC8166].
 In other words, the peer MUST behave as if a Private Data message was
 received in which (1) bit 15 of the Flags field is zero and (2) both
 Size fields contain the value zero.

5.2. Interoperability amongst RDMA Transports

 The Format Identifier field defined in Section 4 is provided to
 enable implementations to distinguish the Private Data defined in
 this document from Private Data inserted at other layers, such as the
 additional Private Data defined by the MPAv2 protocol described in
 [RFC6581], and others.
 As part of connection establishment, the buffer containing the
 received Private Data is searched for the Format Identifier word.
 The offset of the Format Identifier is not restricted to any
 alignment.  If the RPC-over-RDMA version 1 CM Private Data Format
 Identifier is not present, an RPC-over-RDMA version 1 receiver MUST
 behave as if no RPC-over-RDMA version 1 CM Private Data has been
 provided.
 Once the RPC-over-RDMA version 1 CM Private Data Format Identifier is
 found, the receiver parses the subsequent octets as RPC-over-RDMA
 version 1 CM Private Data.  As additional assurance that the content
 is valid RPC-over-RDMA version 1 CM Private Data, the receiver should
 check that the format version number field contains a valid and
 recognized version number and the size of the content does not
 overrun the length of the buffer.

6. Updating the Message Format

 Although the message format described in this document provides the
 ability for the client and server to exchange particular information
 about the local RPC-over-RDMA implementation, it is possible that
 there will be a future need to exchange additional properties.  This
 would make it necessary to extend or otherwise modify the format
 described in this document.
 Any modification faces the problem of interoperating properly with
 implementations of RPC-over-RDMA version 1 that are unaware of the
 existence of the new format.  These include implementations that do
 not recognize the exchange of CM Private Data as well as those that
 recognize only the format described in this document.
 Given the message format described in this document, these
 interoperability constraints could be met by the following sorts of
 new message formats:
  • A format that uses a different value for the first four bytes of

the format, as provided for in the registry described in

    Section 8.
  • A format that uses the same value for the Format Identifier field

and a value other than one (1) in the Version field.

 Although it is possible to reorganize the last three of the
 eight bytes in the existing format, extended formats are unlikely to
 do so.  New formats would take the form of extensions of the format
 described in this document with added fields starting at byte eight
 of the format or changes to the definition of bits in the Reserved
 field.

7. Security Considerations

 The reader is directed to the Security Considerations section of
 [RFC8166] for background and further discussion.
 The RPC-over-RDMA version 1 protocol framework depends on the
 semantics of the Reliable Connected (RC) queue pair (QP) type, as
 defined in Section 9.7.7 of [IBA].  The integrity of CM Private Data
 and the authenticity of its source are ensured by the exclusive use
 of RC QPs.  Any attempt to interfere with or hijack data in transit
 on an RC connection results in the RDMA provider terminating the
 connection.
 The Security Considerations section of [RFC5042] refers the reader to
 further relevant discussion of generic RDMA transport security.  That
 document recommends IPsec as the default transport-layer security
 solution.  When deployed with the Remote Direct Memory Access
 Protocol (RDMAP) [RFC5040], DDP [RFC5041], and MPA [RFC5044], IPsec
 establishes a protected channel before any operations are exchanged;
 thus, it protects the exchange of Private Data.  However, IPsec is
 not available for InfiniBand or RDMA over Converged Ethernet (RoCE)
 deployments.  Those fabrics rely on physical security and cyclic
 redundancy checks to protect network traffic.
 Exchanging the information contained in the message format defined in
 this document does not expose upper-layer payloads to an attacker.
 Furthermore, the behavior changes that occur as a result of
 exchanging the Private Data described in the current document do not
 introduce any new risk of exposure of upper-layer payload data.
 Improperly setting one of the fields in version 1 Private Data can
 result in an increased risk of disconnection (i.e., self-imposed
 Denial of Service).  A similar risk can arise if non-RPC-over-RDMA CM
 Private Data inadvertently contains the Format Identifier that
 identifies this protocol's data structure.  Additional checking of
 incoming Private Data, as described in Section 5.2, can help reduce
 this risk.
 In addition to describing the structure of a new format version, any
 document that extends the Private Data format described in the
 current document must discuss security considerations of new data
 items exchanged between connection peers.  Such documents should also
 explore the risks of erroneously identifying non-RPC-over-RDMA CM
 Private Data as the new format.

8. IANA Considerations

 IANA has created the "RDMA-CM Private Data Identifiers" subregistry
 within the "Remote Direct Data Placement" protocol category group.
 This is a subregistry of 32-bit numbers that identify the upper-layer
 protocol associated with data that appears in the application-
 specific RDMA-CM Private Data area.  The fields in this subregistry
 include the following: Format Identifier, Length (format length, in
 octets), Description, and Reference.
 The initial contents of this registry are a single entry:
 +===================+========+=======================+===========+
 | Format Identifier | Length | Description           | Reference |
 +===================+========+=======================+===========+
 | 0xf6ab0e18        | 8      | RPC-over-RDMA version | RFC 8797  |
 |                   |        | 1 CM Private Data     |           |
 +-------------------+--------+-----------------------+-----------+
      Table 1: New "RDMA-CM Private Data Identifiers" Registry
 IANA is to assign subsequent new entries in this registry using the
 Specification Required policy as defined in Section 4.6 of [RFC8126].

8.1. Guidance for Designated Experts

 The Designated Expert (DE), appointed by the IESG, should ascertain
 the existence of suitable documentation that defines the semantics
 and format of the Private Data, and verify that the document is
 permanently and publicly available.  Documentation produced outside
 the IETF must not conflict with work that is active or already
 published within the IETF.  The new Reference field should contain a
 reference to that documentation.
 The Description field should contain the name of the upper-layer
 protocol that generates and uses the Private Data.
 The DE should assign a new Format Identifier so that it does not
 conflict with existing entries in this registry and so that it is not
 likely to be mistaken as part of the payload of other registered
 formats.
 The DE shall post the request to the NFSV4 Working Group mailing list
 (or a successor to that list, if such a list exists) for comment and
 review.  The DE shall approve or deny the request and publish notice
 of the decision within 30 days.

9. References

9.1. Normative References

 [IBA]      InfiniBand Trade Association, "InfiniBand Architecture
            Specification Volume 1", Release 1.3, March 2015,
            <https://www.infinibandta.org/>.
 [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
            Requirement Levels", BCP 14, RFC 2119,
            DOI 10.17487/RFC2119, March 1997,
            <https://www.rfc-editor.org/info/rfc2119>.
 [RFC4506]  Eisler, M., Ed., "XDR: External Data Representation
            Standard", STD 67, RFC 4506, DOI 10.17487/RFC4506, May
            2006, <https://www.rfc-editor.org/info/rfc4506>.
 [RFC5040]  Recio, R., Metzler, B., Culley, P., Hilland, J., and D.
            Garcia, "A Remote Direct Memory Access Protocol
            Specification", RFC 5040, DOI 10.17487/RFC5040, October
            2007, <https://www.rfc-editor.org/info/rfc5040>.
 [RFC5042]  Pinkerton, J. and E. Deleganes, "Direct Data Placement
            Protocol (DDP) / Remote Direct Memory Access Protocol
            (RDMAP) Security", RFC 5042, DOI 10.17487/RFC5042, October
            2007, <https://www.rfc-editor.org/info/rfc5042>.
 [RFC8126]  Cotton, M., Leiba, B., and T. Narten, "Guidelines for
            Writing an IANA Considerations Section in RFCs", BCP 26,
            RFC 8126, DOI 10.17487/RFC8126, June 2017,
            <https://www.rfc-editor.org/info/rfc8126>.
 [RFC8166]  Lever, C., Ed., Simpson, W., and T. Talpey, "Remote Direct
            Memory Access Transport for Remote Procedure Call Version
            1", RFC 8166, DOI 10.17487/RFC8166, June 2017,
            <https://www.rfc-editor.org/info/rfc8166>.
 [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
            2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
            May 2017, <https://www.rfc-editor.org/info/rfc8174>.

9.2. Informative References

 [RFC1813]  Callaghan, B., Pawlowski, B., and P. Staubach, "NFS
            Version 3 Protocol Specification", RFC 1813,
            DOI 10.17487/RFC1813, June 1995,
            <https://www.rfc-editor.org/info/rfc1813>.
 [RFC5041]  Shah, H., Pinkerton, J., Recio, R., and P. Culley, "Direct
            Data Placement over Reliable Transports", RFC 5041,
            DOI 10.17487/RFC5041, October 2007,
            <https://www.rfc-editor.org/info/rfc5041>.
 [RFC5044]  Culley, P., Elzur, U., Recio, R., Bailey, S., and J.
            Carrier, "Marker PDU Aligned Framing for TCP
            Specification", RFC 5044, DOI 10.17487/RFC5044, October
            2007, <https://www.rfc-editor.org/info/rfc5044>.
 [RFC5531]  Thurlow, R., "RPC: Remote Procedure Call Protocol
            Specification Version 2", RFC 5531, DOI 10.17487/RFC5531,
            May 2009, <https://www.rfc-editor.org/info/rfc5531>.
 [RFC5666]  Talpey, T. and B. Callaghan, "Remote Direct Memory Access
            Transport for Remote Procedure Call", RFC 5666,
            DOI 10.17487/RFC5666, January 2010,
            <https://www.rfc-editor.org/info/rfc5666>.
 [RFC6581]  Kanevsky, A., Ed., Bestler, C., Ed., Sharp, R., and S.
            Wise, "Enhanced Remote Direct Memory Access (RDMA)
            Connection Establishment", RFC 6581, DOI 10.17487/RFC6581,
            April 2012, <https://www.rfc-editor.org/info/rfc6581>.
 [RFC7530]  Haynes, T., Ed. and D. Noveck, Ed., "Network File System
            (NFS) Version 4 Protocol", RFC 7530, DOI 10.17487/RFC7530,
            March 2015, <https://www.rfc-editor.org/info/rfc7530>.
 [RFC7861]  Adamson, A. and N. Williams, "Remote Procedure Call (RPC)
            Security Version 3", RFC 7861, DOI 10.17487/RFC7861,
            November 2016, <https://www.rfc-editor.org/info/rfc7861>.

Acknowledgments

 Thanks to Christoph Hellwig and Devesh Sharma for suggesting this
 approach, and to Tom Talpey and David Noveck for their expert
 comments and review.  The author also wishes to thank Bill Baker and
 Greg Marsden for their support of this work.  Also, thanks to expert
 reviewers Sean Hefty and Dave Minturn.
 Special thanks go to document shepherd Brian Pawlowski, Transport
 Area Director Magnus Westerlund, NFSV4 Working Group Chairs David
 Noveck and Spencer Shepler, and NFSV4 Working Group Secretary Thomas
 Haynes.

Author's Address

 Charles Lever
 Oracle Corporation
 United States of America
 Email: chuck.lever@oracle.com