                Data Center Benchmarking Terminology

Abstract

 The purposes of this informational document are to establish
 definitions and describe measurement techniques for data center
 benchmarking, as well as to introduce new terminology applicable to
 performance evaluations of data center network equipment.  This
 document establishes the important concepts for benchmarking network
 switches and routers in the data center and is a prerequisite for the
 test methodology document (RFC 8239).  Many of these terms and
 methods may be applicable to network equipment beyond the scope of
 this document as the technologies originally applied in the data
 center are deployed elsewhere.

Status of This Memo

 This document is not an Internet Standards Track specification; it is
 published for informational purposes.
 This document is a product of the Internet Engineering Task Force
 (IETF).  It represents the consensus of the IETF community.  It has
 received public review and has been approved for publication by the
 Internet Engineering Steering Group (IESG).  Not all documents
 approved by the IESG are a candidate for any level of Internet
 Standard; see Section 2 of RFC 7841.
 Information about the current status of this document, any errata,
 and how to provide feedback on it may be obtained at
 http://www.rfc-editor.org/info/rfc8238.

Avramov & Rapp Informational [Page 1] RFC 8238 Data Center Benchmarking Terminology August 2017

Copyright Notice

 Copyright (c) 2017 IETF Trust and the persons identified as the
 document authors.  All rights reserved.
 This document is subject to BCP 78 and the IETF Trust's Legal
 Provisions Relating to IETF Documents
 (http://trustee.ietf.org/license-info) in effect on the date of
 publication of this document.  Please review these documents
 carefully, as they describe your rights and restrictions with respect
 to this document.  Code Components extracted from this document must
 include Simplified BSD License text as described in Section 4.e of
 the Trust Legal Provisions and are provided without warranty as
 described in the Simplified BSD License.

Avramov & Rapp Informational [Page 2] RFC 8238 Data Center Benchmarking Terminology August 2017

Table of Contents

 1. Introduction ....................................................4
    1.1. Requirements Language ......................................5
    1.2. Definition Format ..........................................5
 2. Latency .........................................................5
    2.1. Definition .................................................5
    2.2. Discussion .................................................7
    2.3. Measurement Units ..........................................7
 3. Jitter ..........................................................8
    3.1. Definition .................................................8
    3.2. Discussion .................................................8
    3.3. Measurement Units ..........................................8
 4. Calibration of the Physical Layer ...............................9
    4.1. Definition .................................................9
    4.2. Discussion .................................................9
    4.3. Measurement Units ..........................................9
 5. Line Rate ......................................................10
    5.1. Definition ................................................10
    5.2. Discussion ................................................10
    5.3. Measurement Units .........................................11
 6. Buffering ......................................................12
    6.1. Buffer ....................................................12
         6.1.1. Definition .........................................12
         6.1.2. Discussion .........................................14
         6.1.3. Measurement Units ..................................14
    6.2. Incast ....................................................15
         6.2.1. Definition .........................................15
         6.2.2. Discussion .........................................15
         6.2.3. Measurement Units ..................................16
 7. Application Throughput: Data Center Goodput ....................16
    7.1. Definition ................................................16
    7.2. Discussion ................................................16
    7.3. Measurement Units .........................................16
 8. Security Considerations ........................................17
 9. IANA Considerations ............................................18
 10. References ....................................................18
    10.1. Normative References .....................................18
    10.2. Informative References ...................................19
 Acknowledgments ...................................................20
 Authors' Addresses ................................................20

Avramov & Rapp Informational [Page 3] RFC 8238 Data Center Benchmarking Terminology August 2017

1. Introduction

 Traffic patterns in the data center are not uniform and are
 constantly changing.  They are dictated by the nature and variety of
 applications utilized in the data center.  They can be largely
 east-west traffic flows (server to server inside the data center) in
 one data center and north-south (from the outside of the data center
 to the server) in another, while some may combine both.  Traffic
 patterns can be bursty in nature and contain many-to-one,
 many-to-many, or one-to-many flows.  Each flow may also be small and
 latency sensitive or large and throughput sensitive while containing
 a mix of UDP and TCP traffic.  All of these may coexist in a single
 cluster and flow through a single network device simultaneously.
 Benchmarking tests for network devices have long used [RFC1242],
 [RFC2432], [RFC2544], [RFC2889], and [RFC3918].  These benchmarks
 have largely been focused around various latency attributes and max
 throughput of the Device Under Test (DUT) being benchmarked.  These
 standards are good at measuring theoretical max throughput,
 forwarding rates, and latency under testing conditions, but they do
 not represent real traffic patterns that may affect these networking
 devices.  The data center networking devices covered are switches and
 routers.
 Currently, typical data center networking devices are
 characterized by:
  1. High port density (48 ports or more).
  1. High speed (currently, up to 100 GB/s per port).
  1. High throughput (line rate on all ports for Layer 2 and/or

Layer 3).

  1. Low latency (in the microsecond or nanosecond range).
  1. Low amount of buffer (in the MB range per networking device).
  1. Layer 2 and Layer 3 forwarding capability (Layer 3 not mandatory).
 This document defines a set of definitions, metrics, and new
 terminology, including congestion scenarios and switch buffer
 analysis, and redefines basic definitions in order to represent a
 wide mix of traffic conditions.  The test methodologies are defined
 in [RFC8239].

Avramov & Rapp Informational [Page 4] RFC 8238 Data Center Benchmarking Terminology August 2017

1.1. Requirements Language

 The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
 "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
 "OPTIONAL" in this document are to be interpreted as described in
 BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all
 capitals, as shown here.

1.2. Definition Format

  1. Term to be defined (e.g., "latency").
  1. Definition: The specific definition for the term.
  1. Discussion: A brief discussion about the term, its application,

and any restrictions on measurement procedures.

  1. Measurement Units: Methodology for measurements and units used to

report measurements of the term in question, if applicable.

2. Latency

2.1. Definition

 Latency is the amount of time it takes a frame to transit the DUT.
 Latency is measured in units of time (seconds, milliseconds,
 microseconds, and so on).  The purpose of measuring latency is to
 understand the impact of adding a device in the communication path.
 The latency interval can be assessed between different combinations
 of events, regardless of the type of switching device
 (bit forwarding, aka cut-through; or a store-and-forward device).
 [RFC1242] defined latency differently for each of these types of
 devices.
 Traditionally, the latency measurement definitions are:
  1. FILO (First In Last Out):
    The time interval starting when the end of the first bit of the
    input frame reaches the input port and ending when the last bit of
    the output frame is seen on the output port.

Avramov & Rapp Informational [Page 5] RFC 8238 Data Center Benchmarking Terminology August 2017

  1. FIFO (First In First Out):
    The time interval starting when the end of the first bit of the
    input frame reaches the input port and ending when the start of
    the first bit of the output frame is seen on the output port.
    Latency (as defined in [RFC1242]) for bit-forwarding devices uses
    these events.
  1. LILO (Last In Last Out):
    The time interval starting when the last bit of the input frame
    reaches the input port and the last bit of the output frame is
    seen on the output port.
  1. LIFO (Last In First Out):
    The time interval starting when the last bit of the input frame
    reaches the input port and ending when the first bit of the output
    frame is seen on the output port.  Latency (as defined in
    [RFC1242]) for store-and-forward devices uses these events.
 Another possible way to summarize the four definitions above is to
 refer to the bit positions as they normally occur: input to output.
  1. FILO is FL (First bit Last bit).
  1. FIFO is FF (First bit First bit).
  1. LILO is LL (Last bit Last bit).
  1. LIFO is LF (Last bit First bit).
 This definition, as explained in this section in the context of
 data center switch benchmarking, is in lieu of the previous
 definition of "latency" as provided in RFC 1242, Section 3.8 and
 quoted here:
    For store and forward devices: The time interval starting when the
    last bit of the input frame reaches the input port and ending when
    the first bit of the output frame is seen on the output port.
    For bit forwarding devices: The time interval starting when the
    end of the first bit of the input frame reaches the input port and
    ending when the start of the first bit of the output frame is seen
    on the output port.

Avramov & Rapp Informational [Page 6] RFC 8238 Data Center Benchmarking Terminology August 2017

 To accommodate both types of network devices and hybrids of the two
 types that have emerged, switch latency measurements made according
 to this document MUST be measured with the FILO events.  FILO will
 include the latency of the switch and the latency of the frame as
 well as the serialization delay.  It is a picture of the "whole"
 latency going through the DUT.  For applications that are latency
 sensitive and can function with initial bytes of the frame, FIFO
 (or, for bit-forwarding devices, latency per RFC 1242) MAY be used.
 In all cases, the event combinations used in latency measurements
 MUST be reported.

2.2. Discussion

 As mentioned in Section 2.1, FILO is the most important measuring
 definition.
 Not all DUTs are exclusively cut-through or store-and-forward.
 Data center DUTs are frequently store-and-forward for smaller packet
 sizes and then change to cut-through behavior at specific larger
 packet sizes.  The value of the packet size at which the behavior
 changes MAY be configurable, depending on the DUT manufacturer.  FILO
 covers both scenarios: store-and-forward and cut-through.  The
 threshold for the change in behavior does not matter for
 benchmarking, since FILO covers both possible scenarios.
 The LIFO mechanism can be used with store-and-forward switches
 but not with cut-through switches, as it will provide negative
 latency values for larger packet sizes because LIFO removes the
 serialization delay.  Therefore, this mechanism MUST NOT be used when
 comparing the latencies of two different DUTs.

2.3. Measurement Units

 The measuring methods to use for benchmarking purposes are as
 follows:
 1) FILO MUST be used as a measuring method, as this will include the
    latency of the packet; today, the application commonly needs to
    read the whole packet to process the information and take an
    action.
 2) FIFO MAY be used for certain applications able to process the data
    as the first bits arrive -- for example, with a Field-Programmable
    Gate Array (FPGA).
 3) LIFO MUST NOT be used because, unlike all the other methods, it
    subtracts the latency of the packet.

Avramov & Rapp Informational [Page 7] RFC 8238 Data Center Benchmarking Terminology August 2017

3. Jitter

3.1. Definition

 In the context of the data center, jitter is synonymous with the
 common term "delay variation".  It is derived from multiple
 measurements of one-way delay, as described in RFC 3393.  The
 mandatory definition of "delay variation" is the Packet Delay
 Variation (PDV) as defined in Section 4.2 of [RFC5481].  When
 considering a stream of packets, the delays of all packets are
 subtracted from the minimum delay over all packets in the stream.
 This facilitates the assessment of the range of delay variation
 (Max - Min) or a high percentile of PDV (99th percentile, for
 robustness against outliers).
 When First-bit to Last-bit timestamps are used for delay measurement,
 then delay variation MUST be measured using packets or frames of the
 same size, since the definition of latency includes the serialization
 time for each packet.  Otherwise, if using First-bit to First-bit,
 the size restriction does not apply.

3.2. Discussion

 In addition to a PDV range and/or a high percentile of PDV,
 Inter-Packet Delay Variation (IPDV) as defined in Section 4.1 of
 [RFC5481] (differences between two consecutive packets) MAY be used
 for the purpose of determining how packet spacing has changed during
 transfer -- for example, to see if a packet stream has become closely
 spaced or "bursty".  However, the absolute value of IPDV SHOULD NOT
 be used, as this "collapses" the "bursty" and "dispersed" sides of
 the IPDV distribution together.

3.3. Measurement Units

 The measurement of delay variation is expressed in units of seconds.
 A PDV histogram MAY be provided for the population of packets
 measured.

Avramov & Rapp Informational [Page 8] RFC 8238 Data Center Benchmarking Terminology August 2017

4. Calibration of the Physical Layer

4.1. Definition

 Calibration of the physical layer consists of defining and measuring
 the latency of the physical devices used to perform tests on the DUT.
 It includes the list of all physical-layer components used, as
 specified here:
  1. Type of device used to generate traffic / measure traffic.
  1. Type of line cards used on the traffic generator.
  1. Type of transceivers on the traffic generator.
  1. Type of transceivers on the DUT.
  1. Type of cables.
  1. Length of cables.
  1. Software name and version of the traffic generator and DUT.
  1. A list of enabled features on the DUT MAY be provided and is

recommended (especially in the case of control-plane protocols,

    such as the Link Layer Discovery Protocol and Spanning Tree).  A
    comprehensive configuration file MAY be provided to this effect.

4.2. Discussion

 Calibration of the physical layer contributes to end-to-end latency
 and should be taken into account when evaluating the DUT.  Small
 variations in the physical components of the test may impact the
 latency being measured; therefore, they MUST be described when
 presenting results.

4.3. Measurement Units

 It is RECOMMENDED that all cables used for testing (1) be of the same
 type and length and (2) come from the same vendor whenever possible.
 It is a MUST to document the cable specifications listed in
 Section 4.1, along with the test results.  The test report MUST
 specify whether or not the cable latency has been subtracted from the
 test measurements.  The accuracy of the traffic-generator
 measurements MUST be provided (for current test equipment, this is
 usually a value within a range of 20 ns).

Avramov & Rapp Informational [Page 9] RFC 8238 Data Center Benchmarking Terminology August 2017

5. Line Rate

5.1. Definition

 The transmit timing, or maximum transmitted data rate, is controlled
 by the "transmit clock" in the DUT.  The receive timing (maximum
 ingress data rate) is derived from the transmit clock of the
 connected interface.
 The line rate or physical-layer frame rate is the maximum capacity to
 send frames of a specific size at the transmit clock frequency of
 the DUT.
 The term "nominal value of line rate" defines the maximum speed
 capability for the given port -- for example (expressed as Gigabit
 Ethernet), 1 GE, 10 GE, 40 GE, 100 GE.
 The frequency ("clock rate") of the transmit clock in any two
 connected interfaces will never be precisely the same; therefore, a
 tolerance is needed.  This will be expressed by a Parts Per Million
 (PPM) value.  The IEEE standards allow a specific +/- variance in the
 transmit clock rate, and Ethernet is designed to allow for small,
 normal variations between the two clock rates.  This results in a
 tolerance of the line-rate value when traffic is generated from test
 equipment to a DUT.
 Line rate SHOULD be measured in frames per second (FPS).

5.2. Discussion

 For a transmit clock source, most Ethernet switches use "clock
 modules" (also called "oscillator modules") that are sealed,
 internally temperature-compensated, and very accurate.  The output
 frequency of these modules is not adjustable because it is not
 necessary.  Many test sets, however, offer a software-controlled
 adjustment of the transmit clock rate.  These adjustments SHOULD be
 used to "compensate" the test equipment in order to not send more
 than the line rate of the DUT.
 To allow for the minor variations typically found in the clock rate
 of commercially available clock modules and other crystal-based
 oscillators, Ethernet standards specify the maximum transmit
 clock-rate variation to be not more than +/- 100 PPM from a
 calculated center frequency.  Therefore, a DUT must be able to accept
 frames at a rate within +/- 100 PPM to comply with the standards.

Avramov & Rapp Informational [Page 10] RFC 8238 Data Center Benchmarking Terminology August 2017

 Very few clock circuits are precisely +/- 0.0 PPM because:
 1. The Ethernet standards allow a maximum variance of +/- 100 PPM
    over time.  Therefore, it is normal for the frequency of the
    oscillator circuits to experience variation over time and over a
    wide temperature range, among other external factors.
 2. The crystals, or clock modules, usually have a specific +/- PPM
    variance that is significantly better than +/- 100 PPM.
    Oftentimes, this is +/- 30 PPM or better in order to be considered
    a "certification instrument".
 When testing an Ethernet switch throughput at "line rate", any
 specific switch will have a clock-rate variance.  If a test set is
 running +1 PPM faster than a switch under test and a sustained
 line-rate test is performed, a gradual increase in latency and,
 eventually, packet drops as buffers fill and overflow in the switch,
 can be observed.  Depending on how much clock variance there is
 between the two connected systems, the effect may be seen after the
 traffic stream has been running for a few hundred microseconds, a few
 milliseconds, or seconds.  The same low latency, and no packet loss,
 can be demonstrated by setting the test set's link occupancy to
 slightly less than 100 percent link occupancy.  Typically, 99 percent
 link occupancy produces excellent low latency and no packet loss.  No
 Ethernet switch or router will have a transmit clock rate of exactly
 +/- 0.0 PPM.  Very few (if any) test sets have a clock rate that is
 precisely +/- 0.0 PPM.
 Test-set equipment manufacturers are well aware of the standards and
 allow a software-controlled +/- 100 PPM "offset" (clock-rate
 adjustment) to compensate for normal variations in the clock speed of
 DUTs.  This offset adjustment allows engineers to determine the
 approximate speed at which the connected device is operating and
 verify that it is within parameters allowed by standards.

5.3. Measurement Units

 "Line rate" can be measured in terms of "frame rate":
 Frame Rate = Transmit-Clock-Frequency /
    (Frame-Length*8 + Minimum_Gap + Preamble + Start-Frame Delimiter)
 Minimum_Gap represents the interframe gap.  This formula "scales up"
 or "scales down" to represent 1 GB Ethernet, 10 GB Ethernet, and
 so on.

Avramov & Rapp Informational [Page 11] RFC 8238 Data Center Benchmarking Terminology August 2017

 Example for 1 GB Ethernet speed with 64-byte frames:
    Frame Rate = 1,000,000,000 / (64*8 + 96 + 56 + 8)
               = 1,000,000,000 / 672
               = 1,488,095.2 FPS
 Considering the allowance of +/- 100 PPM, a switch may "legally"
 transmit traffic at a frame rate between 1,487,946.4 FPS and
 1,488,244 FPS.  Each 1 PPM variation in clock rate will translate to
 a frame-rate increase or decrease of 1.488 FPS.
 In a production network, it is very unlikely that one would see
 precise line rate over a very brief period.  There is no observable
 difference between dropping packets at 99% of line rate and 100% of
 line rate.
 Line rate can be measured at 100% of line rate with a -100 PPM
 adjustment.
 Line rate SHOULD be measured at 99.98% with a 0 PPM adjustment.
 The PPM adjustment SHOULD only be used for a line-rate measurement.

6. Buffering

6.1. Buffer

6.1.1. Definition

 Buffer Size: The term "buffer size" represents the total amount of
    frame-buffering memory available on a DUT.  This size is expressed
    in B (bytes), KB (kilobytes), MB (megabytes), or GB (gigabytes).
    When the buffer size is expressed, an indication of the frame MTU
    (Maximum Transmission Unit) used for that measurement is also
    necessary, as well as the CoS (Class of Service) or DSCP
    (Differentiated Services Code Point) value set, as oftentimes the
    buffers are carved by a quality-of-service implementation.  Please
    refer to Section 3 of [RFC8239] for further details.
    Example: The Buffer Size of the DUT when sending 1518-byte frames
    is 18 MB.
 Port Buffer Size: The port buffer size is the amount of buffer for
    a single ingress port, a single egress port, or a combination of
    ingress and egress buffering locations for a single port.  We
    mention the three locations for the port buffer because the DUT's

Avramov & Rapp Informational [Page 12] RFC 8238 Data Center Benchmarking Terminology August 2017

    buffering scheme can be unknown or untested, so knowing the buffer
    location helps clarify the buffer architecture and, consequently,
    the total buffer size.  The Port Buffer Size is an informational
    value that MAY be provided by the DUT vendor.  It is not a value
    that is tested by benchmarking.  Benchmarking will be done using
    the Maximum Port Buffer Size or Maximum Buffer Size methodology.
 Maximum Port Buffer Size: In most cases, this is the same as the Port
    Buffer Size.  In a certain type of switch architecture called
    "SoC" (switch on chip), there is a port buffer and a shared buffer
    pool available for all ports.  The Maximum Port Buffer Size, in
    terms of an SoC buffer, represents the sum of the port buffer and
    the maximum value of shared buffer allowed for this port, defined
    in terms of B (bytes), KB (kilobytes), MB (megabytes), or GB
    (gigabytes).  The Maximum Port Buffer Size needs to be expressed
    along with the frame MTU used for the measurement and the CoS or
    DSCP bit value set for the test.
    Example: A DUT has been measured to have 3 KB of port buffer for
    1518-byte frames, and a total of 4.7 MB of maximum port buffer for
    1518-byte frames and a CoS of 0.
 Maximum DUT Buffer Size: This is the total buffer size that a DUT can
    be measured to have.  It is most likely different than the Maximum
    Port Buffer Size.  It can also be different from the sum of
    Maximum Port Buffer Size.  The Maximum Buffer Size needs to be
    expressed along with the frame MTU used for the measurement and
    along with the CoS or DSCP value set during the test.
    Example: A DUT has been measured to have 3 KB of port buffer for
    1518-byte frames and a total of 4.7 MB of maximum port buffer for
    1518-byte frames.  The DUT has a Maximum Buffer Size of 18 MB at
    1500 B and a CoS of 0.
 Burst: A burst is a fixed number of packets sent over a percentage of
    line rate for a defined port speed.  The amount of frames sent is
    evenly distributed across the interval T.  A constant, C, can be
    defined to provide the average time between two evenly spaced
    consecutive packets.
 Microburst: A microburst is a type of burst where packet drops occur
    when there is not sustained or noticeable congestion on a link or
    device.  One characteristic of a microburst is when the burst
    is not evenly distributed over T and is less than the constant C
    (C = the average time between two evenly spaced consecutive
    packets).

Avramov & Rapp Informational [Page 13] RFC 8238 Data Center Benchmarking Terminology August 2017

 Intensity of Microburst: This is a percentage and represents the
    level, between 1 and 100%, of the microburst.  The higher the
    number, the higher the microburst is.
    I=[1-[ (Tp2-Tp1)+(Tp3-Tp2)+....(TpN-Tp(n-1) ] / Sum(packets)]]*100
 The above definitions are not meant to comment on the ideal sizing of
 a buffer but rather on how to measure it.  A larger buffer is not
 necessarily better and can cause issues with bufferbloat.

6.1.2. Discussion

 When measuring buffering on a DUT, it is important to understand the
 behavior of each and every port.  This provides data for the total
 amount of buffering available on the switch.  The terms of buffer
 efficiency help one understand the optimum packet size for the buffer
 or the real volume of the buffer available for a specific packet
 size.  This section does not discuss how to conduct the test
 methodology; instead, it explains the buffer definitions and what
 metrics should be provided for comprehensive data center
 device-buffering benchmarking.

6.1.3. Measurement Units

 When the DUT buffer is measured:
  1. The buffer size MUST be measured.
  1. The port buffer size MAY be provided for each port.
  1. The maximum port buffer size MUST be measured.
  1. The maximum DUT buffer size MUST be measured.
  1. The intensity of the microburst MAY be mentioned when a microburst

test is performed.

  1. The CoS or DSCP value set during the test SHOULD be provided.

Avramov & Rapp Informational [Page 14] RFC 8238 Data Center Benchmarking Terminology August 2017

6.2. Incast

6.2.1. Definition

 The term "Incast", very commonly utilized in the data center, refers
 to the many-to-one or many-to-many traffic patterns.  As defined in
 this section, it measures the number of ingress and egress ports and
 the percentage of synchronization attributed to them.  Typically, in
 the data center, it would refer to many different ingress server
 ports (many), sending traffic to a common uplink (many-to-one), or
 multiple uplinks (many-to-many).  This pattern is generalized for any
 network as many incoming ports sending traffic to one or a few
 uplinks.
 Synchronous arrival time: When two or more frames of sizes L1 and L2
    arrive at their respective ingress port or multiple ingress ports
    and there is an overlap of arrival times for any of the bits on
    the DUT, then the L1 and L2 frames have synchronous arrival times.
    This is called "Incast", regardless of whether the pattern is
    many-to-one (simpler) or many-to-many.
 Asynchronous arrival time: This is any condition not defined by
    "synchronous arrival time".
 Percentage of synchronization: This defines the level of overlap
    (amount of bits) between frames of sizes L1,L2..Ln.
    Example: Two 64-byte frames of length L1 and L2 arrive at ingress
    port 1 and port 2 of the DUT.  There is an overlap of 6.4 bytes
    between the two, where the L1 and L2 frames were on their
    respective ingress ports at the same time.  Therefore, the
    percentage of synchronization is 10%.
 Stateful traffic: Stateful traffic is packets exchanged with a
    stateful protocol, such as TCP.
 Stateless traffic: Stateless traffic is packets exchanged with a
    stateless protocol, such as UDP.

6.2.2. Discussion

 In this scenario, buffers are used on the DUT.  In an ingress
 buffering mechanism, the ingress port buffers would be used along
 with virtual output queues, when available, whereas in an egress
 buffering mechanism, the egress buffer of the one outgoing port would
 be used.

Avramov & Rapp Informational [Page 15] RFC 8238 Data Center Benchmarking Terminology August 2017

 In either case, regardless of where the buffer memory is located in
 the switch architecture, the Incast creates buffer utilization.
 When one or more frames have synchronous arrival times at the DUT,
 they are considered to be forming an Incast.

6.2.3. Measurement Units

 It is a MUST to measure the number of ingress and egress ports.
 It is a MUST to have a non-null percentage of synchronization, which
 MUST be specified.

7. Application Throughput: Data Center Goodput

7.1. Definition

 In data center networking, a balanced network is a function of
 maximal throughput and minimal loss at any given time.  This is
 captured by the Goodput [TCP-INCAST].  Goodput is the
 application-level throughput.  For standard TCP applications, a very
 small loss can have a dramatic effect on application throughput.
 [RFC2647] provides a definition of Goodput; the definition in this
 document is a variant of that definition.
 Goodput is the number of bits per unit of time forwarded to the
 correct destination interface of the DUT, minus any bits
 retransmitted.

7.2. Discussion

 In data center benchmarking, the goodput is a value that SHOULD be
 measured.  It provides a realistic idea of the usage of the available
 bandwidth.  A goal in data center environments is to maximize the
 goodput while minimizing loss.

7.3. Measurement Units

 The Goodput, G, is then measured by the following formula:
    G = (S/F) x V bytes per second
  1. S represents the payload bytes, not including packet or

TCP headers.

  1. F is the frame size.
  1. V is the speed of the media in bytes per second.

Avramov & Rapp Informational [Page 16] RFC 8238 Data Center Benchmarking Terminology August 2017

    Example: A TCP file transfer over HTTP on 10 GB/s media.
    The file cannot be transferred over Ethernet as a single
    continuous stream.  It must be broken down into individual frames
    of 1500 B when the standard MTU is used.  Each packet requires
    20 B of IP header information and 20 B of TCP header information;
    therefore, 1460 B are available per packet for the file transfer.
    Linux-based systems are further limited to 1448 B, as they also
    carry a 12 B timestamp.  Finally, in this example the date is
    transmitted over Ethernet, which adds 26 B of overhead per packet
    to 1500 B, increasing it to 1526 B.
    G = 1460/1526 x 10 Gbit/s, which is 9.567 Gbit/s or 1.196 GB/s.
    Please note: This example does not take into consideration the
    additional Ethernet overhead, such as the interframe gap (a
    minimum of 96 bit times), nor does it account for collisions
    (which have a variable impact, depending on the network load).
 When conducting Goodput measurements, please document, in addition to
 the items listed in Section 4.1, the following information:
  1. The TCP stack used.
  1. OS versions.
  1. Network Interface Card (NIC) firmware version and model.
 For example, Windows TCP stacks and different Linux versions can
 influence TCP-based test results.

8. Security Considerations

 Benchmarking activities as described in this memo are limited to
 technology characterization using controlled stimuli in a laboratory
 environment, with dedicated address space and the constraints
 specified in the sections above.
 The benchmarking network topology will be an independent test setup
 and MUST NOT be connected to devices that may forward the test
 traffic into a production network or misroute traffic to the test
 management network.
 Further, benchmarking is performed on a "black-box" basis, relying
 solely on measurements observable external to the DUT.

Avramov & Rapp Informational [Page 17] RFC 8238 Data Center Benchmarking Terminology August 2017

 Special capabilities SHOULD NOT exist in the DUT specifically for
 benchmarking purposes.  Any implications for network security arising
 from the DUT SHOULD be identical in the lab and in production
 networks.

9. IANA Considerations

 This document does not require any IANA actions.

10. References

10.1. Normative References

 [RFC1242]  Bradner, S., "Benchmarking Terminology for Network
            Interconnection Devices", RFC 1242, DOI 10.17487/RFC1242,
            July 1991, <https://www.rfc-editor.org/info/rfc1242>.
 [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
            Requirement Levels", BCP 14, RFC 2119,
            DOI 10.17487/RFC2119, March 1997,
            <https://www.rfc-editor.org/info/rfc2119>.
 [RFC2544]  Bradner, S. and J. McQuaid, "Benchmarking Methodology for
            Network Interconnect Devices", RFC 2544,
            DOI 10.17487/RFC2544, March 1999,
            <https://www.rfc-editor.org/info/rfc2544>.
 [RFC5481]  Morton, A. and B. Claise, "Packet Delay Variation
            Applicability Statement", RFC 5481, DOI 10.17487/RFC5481,
            March 2009, <https://www.rfc-editor.org/info/rfc5481>.
 [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase in
            RFC 2119 Key Words", BCP 14, RFC 8174,
            DOI 10.17487/RFC8174, May 2017,
            <https://www.rfc-editor.org/info/rfc8174>.
 [RFC8239]  Avramov, L. and J. Rapp, "Data Center Benchmarking
            Methodology", RFC 8239, DOI 10.17487/RFC8239, August 2017,
            <https://www.rfc-editor.org/info/rfc8239>.

Avramov & Rapp Informational [Page 18] RFC 8238 Data Center Benchmarking Terminology August 2017

10.2. Informative References

 [RFC2432]  Dubray, K., "Terminology for IP Multicast Benchmarking",
            RFC 2432, DOI 10.17487/RFC2432, October 1998,
            <https://www.rfc-editor.org/info/rfc2432>.
 [RFC2647]  Newman, D., "Benchmarking Terminology for Firewall
            Performance", RFC 2647, DOI 10.17487/RFC2647, August 1999,
            <https://www.rfc-editor.org/info/rfc2647>.
 [RFC2889]  Mandeville, R. and J. Perser, "Benchmarking Methodology
            for LAN Switching Devices", RFC 2889,
            DOI 10.17487/RFC2889, August 2000,
            <https://www.rfc-editor.org/info/rfc2889>.
 [RFC3918]  Stopp, D. and B. Hickman, "Methodology for IP Multicast
            Benchmarking", RFC 3918, DOI 10.17487/RFC3918,
            October 2004, <https://www.rfc-editor.org/info/rfc3918>.
 [TCP-INCAST]
            Chen, Y., Griffith, R., Zats, D., Joseph, A., and R. Katz,
            "Understanding TCP Incast and Its Implications for Big
            Data Workloads", April 2012, <http://yanpeichen.com/
            professional/usenixLoginIncastReady.pdf>.

Avramov & Rapp Informational [Page 19] RFC 8238 Data Center Benchmarking Terminology August 2017

Acknowledgments

 The authors would like to thank Al Morton, Scott Bradner, Ian Cox,
 and Tim Stevenson for their reviews and feedback.

Authors' Addresses

 Lucien Avramov
 Google
 1600 Amphitheatre Parkway
 Mountain View, CA  94043
 United States of America
 Email: lucien.avramov@gmail.com
 Jacob Rapp
 VMware
 3401 Hillview Ave.
 Palo Alto, CA  94304
 United States of America
 Email: jhrapp@gmail.com