Internet Engineering Task Force (IETF) J. Dong Request for Comments: 7795 H. Wang Category: Standards Track Huawei Technologies ISSN: 2070-1721 February 2016

    Pseudowire Redundancy on the Switching Provider Edge (S-PE)

Abstract

 This document describes Multi-Segment Pseudowire (MS-PW) protection
 scenarios in which pseudowire redundancy is provided on the Switching
 Provider Edge (S-PE) as defined in RFC 5659.  Operations of the S-PEs
 that provide PW redundancy are specified in this document.  Signaling
 of the Preferential Forwarding status as defined in RFCs 6870 and
 6478 is reused.  This document does not require any change to the
 Terminating Provider Edges (T-PEs) of MS-PW.

Status of This Memo

 This is an Internet Standards Track document.
 This document is a product of the Internet Engineering Task Force
 (IETF).  It represents the consensus of the IETF community.  It has
 received public review and has been approved for publication by the
 Internet Engineering Steering Group (IESG).  Further information on
 Internet Standards is available in Section 2 of RFC 5741.
 Information about the current status of this document, any errata,
 and how to provide feedback on it may be obtained at
 http://www.rfc-editor.org/info/rfc7795.

Copyright Notice

 Copyright (c) 2016 IETF Trust and the persons identified as the
 document authors.  All rights reserved.
 This document is subject to BCP 78 and the IETF Trust's Legal
 Provisions Relating to IETF Documents
 (http://trustee.ietf.org/license-info) in effect on the date of
 publication of this document.  Please review these documents
 carefully, as they describe your rights and restrictions with respect
 to this document.  Code Components extracted from this document must
 include Simplified BSD License text as described in Section 4.e of
 the Trust Legal Provisions and are provided without warranty as
 described in the Simplified BSD License.

Dong & Wang Standards Track [Page 1] RFC 7795 PW Redundancy on S-PE February 2016

Table of Contents

 1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   2
 2.  Typical Scenarios of PW Redundancy on S-PE  . . . . . . . . .   3
   2.1.  MS-PW Redundancy on S-PE  . . . . . . . . . . . . . . . .   3
   2.2.  MS-PW Redundancy on S-PE with S-PE Protection . . . . . .   4
 3.  S-PE Operations . . . . . . . . . . . . . . . . . . . . . . .   4
 4.  Applications of PW Redundancy on S-PE . . . . . . . . . . . .   5
   4.1.  Applications in Scenario 1  . . . . . . . . . . . . . . .   5
   4.2.  Applications in Scenario 2  . . . . . . . . . . . . . . .   6
 5.  VCCV Considerations . . . . . . . . . . . . . . . . . . . . .   7
 6.  Security Considerations . . . . . . . . . . . . . . . . . . .   7
 7.  References  . . . . . . . . . . . . . . . . . . . . . . . . .   7
   7.1.  Normative References  . . . . . . . . . . . . . . . . . .   7
   7.2.  Informative References  . . . . . . . . . . . . . . . . .   8
 Acknowledgements  . . . . . . . . . . . . . . . . . . . . . . . .   9
 Authors' Addresses  . . . . . . . . . . . . . . . . . . . . . . .   9

1. Introduction

 [RFC6718] describes the framework and requirements for pseudowire
 (PW) redundancy, and [RFC6870] specifies a PW redundancy mechanism
 for scenarios where a set of redundant PWs are configured between
 Provider Edge (PE) nodes in Single-Segment Pseudowire (SS-PW)
 [RFC3985] applications, or between Terminating Provider Edge (T-PE)
 nodes in Multi-Segment Pseudowire (MS-PW) [RFC5659] applications.
 In some MS-PW scenarios, there are benefits of providing PW
 redundancy on Switching Provider Edges (S-PEs), such as reducing the
 burden on the access T-PE nodes and enabling faster protection
 switching compared to the end-to-end MS-PW protection mechanisms.
 This document describes some scenarios in which PW redundancy is
 provided on S-PEs and specifies the operations of the S-PEs.  The
 S-PEs connect to the neighboring T-PEs or S-PEs with PW segments.
 For the S-PE that provides PW redundancy for an MS-PW, there is a
 single PW segment on one side, which is called the single-homed side,
 and there are multiple PW segments on the other side, which is called
 the multi-homed side.  The scenario in which the S-PE has two multi-
 homed sides is out of scope.  Signaling of the Preferential
 Forwarding status as defined in [RFC6870] and [RFC6478] is reused.
 This document does not require any change to the T-PEs of MS-PW.
 The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
 "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
 document are to be interpreted as described in RFC 2119 [RFC2119].

Dong & Wang Standards Track [Page 2] RFC 7795 PW Redundancy on S-PE February 2016

2. Typical Scenarios of PW Redundancy on S-PE

 In some MS-PW deployment scenarios, there are benefits of providing
 PW redundancy on S-PEs.  This section describes typical scenarios of
 PW redundancy on S-PE.

2.1. MS-PW Redundancy on S-PE

                                             +-----+  AC
         +---+                  +-----+      |     |  |  +---+
         |   |                  |     |------|T-PE2|-----|   |
         |   |  AC +-----+      |  ..PW-Seg2.......|     |   |
         |   |  |  |....PW-Seg1.....  |      +-----+     |   |
         |CE1|-----|T-PE1|------|S-PE1|                  |CE2|
         |   |     |     |      |  .  |      +-----+     |   |
         |   |     +-----+      |  ..PW-Seg3.......|     |   |
         |   |                  |     |------|T-PE3|-----|   |
         +---+                  +-----+      |     |  |  +---+
                                             +-----+  AC
                  Figure 1: MS-PW Redundancy on S-PE
 As illustrated in Figure 1, Customer Edge (CE) node CE1 is connected
 to T-PE1 while CE2 is dual-homed to T-PE2 and T-PE3.  T-PE1 is
 connected to S-PE1 only, and S-PE1 is connected to both T-PE2 and
 T-PE3.  The MS-PW is switched on S-PE1, and PW segments PW-Seg2 and
 PW-Seg3 provide resiliency on S-PE1 for the failure of T-PE2, T-PE3,
 or the connected Attachment Circuits (ACs).  PW-Seg2 is selected as
 the primary PW segment, and PW-Seg3 is the secondary PW segment.
 MS-PW redundancy on S-PE is beneficial for the scenario in Figure 1
 since T-PE1 as an access node may not support PW redundancy.
 Besides, with PW redundancy on S-PE, the number of PW segments
 required between T-PE1 and S-PE1 is only half of the number of PW
 segments needed when end-to-end MS-PW redundancy is used.  In
 addition, in this scenario, PW redundancy on S-PE could provide
 faster protection switching, compared with end-to-end protection
 switching of MS-PW.

Dong & Wang Standards Track [Page 3] RFC 7795 PW Redundancy on S-PE February 2016

2.2. MS-PW Redundancy on S-PE with S-PE Protection

       +---+     +-----+      +-----+           +-----+
       |   |     |     |      |     |           |     |
       |   |  AC |......PW1-Seg1......PW1-Seg2........|
       |   |  |  |   . |      |  .  |           |     |
       |CE1|-----|T-PE1|------|S-PE1|-----------|T-PE2|  AC
       |   |     |   . |      |  .  | PW1-Seg3  |     |  |  +---+
       |   |     |   . |      |  .........      ......|-----|   |
       |   |     |   . |      |     |    .     .|     |     |   |
       +---+     +---.-+      +-----+     .   . +-----+     |   |
                    |.                     . .              |CE2|
                    |.                      ..              |   |
                    |.        +-----+      .  . +-----+     |   |
                    |.        |     |     .    .|     |-----|   |
                    |...PW2-Seg1..........      ......|  |  +---+
                    |         |  .  | PW2-Seg2  |     |  AC
                    ----------|S-PE2|-----------|T-PE3|
                              |  .  |           |     |
                              |  .....PW2-Seg3........|
                              |     |           |     |
                              +-----+           +-----+
        Figure 2: MS-PW Redundancy on S-PE with S-PE Protection
 As illustrated in Figure 2, CE1 is connected to T-PE1 while CE2 is
 dual-homed to T-PE2 and T-PE3.  T-PE1 is connected to both S-PE1 and
 S-PE2, and both S-PE1 and S-PE2 are connected to both T-PE2 and
 T-PE3.  There are two MS-PWs that are switched at S-PE1 and S-PE2,
 respectively, to provide S-PE node protection.  For PW1, S-PE1
 provides resiliency using PW1-Seg2 and PW1-Seg3.  For PW2, S-PE2
 provides resiliency using PW2-Seg2 and PW2-Seg3.  PW1 is the primary
 MS-PW, and PW1-Seg2 between S-PE1 and T-PE2 is the primary PW
 segment.  PW2 is the secondary MS-PW.
 MS-PW redundancy on S-PE is beneficial for this scenario because it
 reduces the number of end-to-end MS-PWs required for both T-PE and
 S-PE protection.  In addition, PW redundancy on S-PE could provide
 faster protection switching, compared with end-to-end protection
 switching of MS-PW.

3. S-PE Operations

 For an S-PE that provides PW redundancy for MS-PW, it is important to
 advertise the proper preferential forwarding status to the PW
 segments on both sides and perform protection switching according to
 the received status information.  Note that when PW redundancy for
 MS-PW is provided on S-PE, the optional S-PE Bypass mode as defined

Dong & Wang Standards Track [Page 4] RFC 7795 PW Redundancy on S-PE February 2016

 in [RFC6478] MUST NOT be used; otherwise, the S-PE will not receive
 the PW status messages originated by T-PEs.  This section specifies
 the operations of S-PEs on which PW redundancy is provisioned.  This
 section does not make any change to the T-PEs of MS-PW.
 The S-PEs connect to the neighboring T-PEs or other S-PEs on two
 sides with PW segments.  For the S-PE that provides PW redundancy for
 an MS-PW, on one side there is a single PW segment, which is called
 the single-homed side, and on the other side there are multiple PW
 segments, which is called the multi-homed side.  The scenario in
 which the S-PE has two multi-homed sides is out of scope.
 The S-PE that provides PW redundancy MUST work in Slave mode for the
 single-homed side, and MUST work in Independent mode for the multi-
 homed side.  Consequently, the T-PE on the single-homed side MUST
 work in the Master mode, and the T-PEs on the multi-homed side MUST
 work in the Independent mode.  The signaling of the Preferential
 Forwarding bit as defined in [RFC6870] and [RFC6478] is reused.
 The S-PE MUST pass the Preferential Forwarding status received from
 the single-homed side unchanged to all the PW segments on the multi-
 homed side.  The S-PE MUST advertise the Standby Preferential
 Forwarding status to the single-homed side if it receives Standby
 status from all the PW segments on the multi-homed side, and it MUST
 advertise the Active Preferential Forwarding status to the single-
 homed side if it receives Active status from any of the PW segments
 on the multi-homed side.  For the single-homed side, the active PW
 segment is determined by the T-PE on this side, which works in the
 Master mode.  On the multi-homed side, since both the S-PE and T-PEs
 work in the Independent mode, the PW segment which has both the local
 and remote Up/Down status as Up and both the local and remote
 Preferential Forwarding status as Active MUST be selected for traffic
 forwarding.  When a switchover happens on the S-PE, if the S-PE
 supports the SP-PE TLV processing as defined in [RFC6073], it SHOULD
 advertise the updated SP-PE TLVs by sending a Label Mapping message
 to the T-PEs.

4. Applications of PW Redundancy on S-PE

4.1. Applications in Scenario 1

 For the scenario in Figure 1, assume the AC from CE2 to T-PE2 is
 active.  In normal operation, S-PE1 would receive the Active
 Preferential Forwarding status bit on the single-homed side from
 T-PE1, then it would advertise the Active Preferential Forwarding
 status bit on both PW-Seg2 and PW-Seg3.  T-PE2 and T-PE3 would
 advertise the Active and Standby Preferential Forwarding status bit
 to S-PE1, respectively, reflecting the forwarding state of the two

Dong & Wang Standards Track [Page 5] RFC 7795 PW Redundancy on S-PE February 2016

 ACs connected to CE2.  By matching the local and remote Up/Down
 status and Preferential Forwarding status, PW-Seg2 would be used for
 traffic forwarding.
 On failure of the AC between CE2 and T-PE2, the forwarding state of
 AC on T-PE3 is changed to Active.  T-PE3 then advertises the Active
 Preferential Forwarding status to S-PE1, and T-PE2 would advertise a
 PW status Notification message to S-PE1, indicating that the AC
 between CE2 and T-PE2 is down.  S-PE1 would perform the switchover
 according to the updated local and remote Preferential Forwarding
 status and the status of "Pseudowire forwarding", and select PW-Seg3
 as the new PW segment for traffic forwarding.  Since S-PE1 still
 connects to an Active PW segment on the multi-homed side, it will not
 advertise any change of the PW status to T-PE1.  If S-PE1 supports
 the SP-PE TLV processing as defined in [RFC6073], it would advertise
 the updated SP-PE TLVs by sending a Label Mapping message to T-PE1.

4.2. Applications in Scenario 2

 For the scenario of Figure 2, assume the AC from CE2 to T-PE2 is
 active.  T-PE1 works in Master mode and it would advertise the Active
 and Standby Preferential Forwarding status bit to S-PE1 and S-PE2
 respectively according to configuration.  According to the received
 Preferential Forwarding status bit, S-PE1 would advertise the Active
 Preferential Forwarding status bit to both T-PE2 and T-PE3, and S-PE2
 would advertise the Standby Preferential Forwarding status bit to
 both T-PE2 and T-PE3.  T-PE2 would advertise the Active Preferential
 Forwarding status bit to both S-PE1 and S-PE2, and T-PE3 would
 advertise the Standby Preferential Forwarding status bit to both
 S-PE1 and S-PE2, reflecting the forwarding state of the two ACs
 connected to CE2.  By matching the local and remote Up/Down Status
 and Preferential Forwarding status, PW1-Seg2 from S-PE1 to T-PE2
 would be used for traffic forwarding.  Since S-PE1 connects to the
 Active PW segment on the multi-homed side, it would advertise the
 Active Preferential Forwarding status bit to T-PE1, and S-PE2 would
 advertise the Standby Preferential Forwarding status bit to T-PE1
 because it does not have any Active PW segment on the multi-homed
 side.
 On failure of the AC between CE2 and T-PE2, the forwarding state of
 AC on T-PE3 is changed to Active.  T-PE3 would then advertise the
 Active Preferential Forwarding status bit to both S-PE1 and S-PE2,
 and T-PE2 would advertise a PW status Notification message to both
 S-PE1 and S-PE2, indicating that the AC between CE2 and T-PE2 is
 down.  S-PE1 would perform the switchover according to the updated
 local and remote Preferential Forwarding status and the status of
 "Pseudowire forwarding", and select PW1-Seg3 for traffic forwarding.
 Since S-PE1 still has an Active PW segment on the multi-homed side,

Dong & Wang Standards Track [Page 6] RFC 7795 PW Redundancy on S-PE February 2016

 it would not advertise any change of the PW status to T-PE1.  If
 S-PE1 supports the SP-PE TLV processing as defined in [RFC6073], it
 would advertise the updated SP-PE TLVs by sending a Label Mapping
 message to T-PE1.
 If S-PE1 fails, T-PE1 would notice this through some detection
 mechanism and then advertise the Active Preferential Forwarding
 status bit to S-PE2, and PW2-Seg1 would be selected by T-PE1 for
 traffic forwarding.  On receipt of the newly changed Preferential
 Forwarding status, S-PE2 would advertise the Active Preferential
 Forwarding status to both T-PE2 and T-PE3.  T-PE2 and T-PE3 would
 also notice the failure of S-PE1 by some detection mechanism.  Then
 by matching the local and remote Up/Down and Preferential Forwarding
 status, PW2-Seg2 would be selected for traffic forwarding.

5. VCCV Considerations

 For PW Virtual Circuit Connectivity Verification (VCCV) [RFC5085],
 the Control Channel (CC) type 1 "PW ACH" can be used with the S-PE
 redundancy mechanism.  VCCV CC type 2 "Router Alert Label" is not
 supported for MS-PW as specified in [RFC6073].  If VCCV CC type 3
 "TTL Expiry" is to be used, the PW label TTL MUST be set to the
 appropriate value to reach the target PE.  The hop count from one
 T-PE to the target PE can be obtained via SP-PE TLVs, through MS-PW
 path trace, or based on management-plane information.

6. Security Considerations

 Since PW redundancy is provided on the S-PE nodes of MS-PWs, it is
 important that the security mechanisms as defined in [RFC4447],
 [RFC6073], and [RFC6478] be implemented to ensure that the S-PE nodes
 and the messages sent and received by the S-PE nodes are not
 compromised.

7. References

7.1. Normative References

 [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
            Requirement Levels", BCP 14, RFC 2119,
            DOI 10.17487/RFC2119, March 1997,
            <http://www.rfc-editor.org/info/rfc2119>.
 [RFC4447]  Martini, L., Ed., Rosen, E., El-Aawar, N., Smith, T., and
            G. Heron, "Pseudowire Setup and Maintenance Using the
            Label Distribution Protocol (LDP)", RFC 4447,
            DOI 10.17487/RFC4447, April 2006,
            <http://www.rfc-editor.org/info/rfc4447>.

Dong & Wang Standards Track [Page 7] RFC 7795 PW Redundancy on S-PE February 2016

 [RFC6073]  Martini, L., Metz, C., Nadeau, T., Bocci, M., and M.
            Aissaoui, "Segmented Pseudowire", RFC 6073,
            DOI 10.17487/RFC6073, January 2011,
            <http://www.rfc-editor.org/info/rfc6073>.
 [RFC6478]  Martini, L., Swallow, G., Heron, G., and M. Bocci,
            "Pseudowire Status for Static Pseudowires", RFC 6478,
            DOI 10.17487/RFC6478, May 2012,
            <http://www.rfc-editor.org/info/rfc6478>.
 [RFC6870]  Muley, P., Ed. and M. Aissaoui, Ed., "Pseudowire
            Preferential Forwarding Status Bit", RFC 6870,
            DOI 10.17487/RFC6870, February 2013,
            <http://www.rfc-editor.org/info/rfc6870>.

7.2. Informative References

 [RFC3985]  Bryant, S., Ed. and P. Pate, Ed., "Pseudo Wire Emulation
            Edge-to-Edge (PWE3) Architecture", RFC 3985,
            DOI 10.17487/RFC3985, March 2005,
            <http://www.rfc-editor.org/info/rfc3985>.
 [RFC5085]  Nadeau, T., Ed. and C. Pignataro, Ed., "Pseudowire Virtual
            Circuit Connectivity Verification (VCCV): A Control
            Channel for Pseudowires", RFC 5085, DOI 10.17487/RFC5085,
            December 2007, <http://www.rfc-editor.org/info/rfc5085>.
 [RFC5659]  Bocci, M. and S. Bryant, "An Architecture for Multi-
            Segment Pseudowire Emulation Edge-to-Edge", RFC 5659,
            DOI 10.17487/RFC5659, October 2009,
            <http://www.rfc-editor.org/info/rfc5659>.
 [RFC6718]  Muley, P., Aissaoui, M., and M. Bocci, "Pseudowire
            Redundancy", RFC 6718, DOI 10.17487/RFC6718, August 2012,
            <http://www.rfc-editor.org/info/rfc6718>.

Dong & Wang Standards Track [Page 8] RFC 7795 PW Redundancy on S-PE February 2016

Acknowledgements

 The authors would like to thank Mach Chen, Lizhong Jin, Mustapha
 Aissaoui, Luca Martini, Matthew Bocci, and Stewart Bryant for their
 valuable comments and discussions.

Authors' Addresses

 Jie Dong
 Huawei Technologies
 Huawei Building, No.156 Beiqing Rd.
 Beijing  100095
 China
 Email: jie.dong@huawei.com
 Haibo Wang
 Huawei Technologies
 Huawei Building, No.156 Beiqing Rd.
 Beijing  100095
 China
 Email: rainsword.wang@huawei.com

Dong & Wang Standards Track [Page 9]