Internet Engineering Task Force (IETF) M. Lasserre Request for Comments: 7365 F. Balus Category: Informational Alcatel-Lucent ISSN: 2070-1721 T. Morin

                                                                Orange
                                                              N. Bitar
                                                               Verizon
                                                            Y. Rekhter
                                                               Juniper
                                                          October 2014
       Framework for Data Center (DC) Network Virtualization

Abstract

 This document provides a framework for Data Center (DC) Network
 Virtualization over Layer 3 (NVO3) and defines a reference model
 along with logical components required to design a solution.

Status of This Memo

 This document is not an Internet Standards Track specification; it is
 published for informational purposes.
 This document is a product of the Internet Engineering Task Force
 (IETF).  It represents the consensus of the IETF community.  It has
 received public review and has been approved for publication by the
 Internet Engineering Steering Group (IESG).  Not all documents
 approved by the IESG are a candidate for any level of Internet
 Standard; see Section 2 of RFC 5741.
 Information about the current status of this document, any errata,
 and how to provide feedback on it may be obtained at
 http://www.rfc-editor.org/info/rfc7365.

Lasserre, et al. Informational [Page 1] RFC 7365 Framework for DC Network Virtualization October 2014

Copyright Notice

 Copyright (c) 2014 IETF Trust and the persons identified as the
 document authors.  All rights reserved.
 This document is subject to BCP 78 and the IETF Trust's Legal
 Provisions Relating to IETF Documents
 (http://trustee.ietf.org/license-info) in effect on the date of
 publication of this document.  Please review these documents
 carefully, as they describe your rights and restrictions with respect
 to this document.  Code Components extracted from this document must
 include Simplified BSD License text as described in Section 4.e of
 the Trust Legal Provisions and are provided without warranty as
 described in the Simplified BSD License.

Lasserre, et al. Informational [Page 2] RFC 7365 Framework for DC Network Virtualization October 2014

Table of Contents

 1. Introduction ....................................................4
    1.1. General Terminology ........................................4
    1.2. DC Network Architecture ....................................7
 2. Reference Models ................................................8
    2.1. Generic Reference Model ....................................8
    2.2. NVE Reference Model .......................................10
    2.3. NVE Service Types .........................................11
         2.3.1. L2 NVE Providing Ethernet LAN-Like Service .........11
         2.3.2. L3 NVE Providing IP/VRF-Like Service ...............11
    2.4. Operational Management Considerations .....................12
 3. Functional Components ..........................................12
    3.1. Service Virtualization Components .........................12
         3.1.1. Virtual Access Points (VAPs) .......................12
         3.1.2. Virtual Network Instance (VNI) .....................12
         3.1.3. Overlay Modules and VN Context .....................14
         3.1.4. Tunnel Overlays and Encapsulation Options ..........14
         3.1.5. Control-Plane Components ...........................14
                3.1.5.1. Distributed vs. Centralized
                         Control Plane .............................14
                3.1.5.2. Auto-provisioning and Service Discovery ...15
                3.1.5.3. Address Advertisement and Tunnel Mapping ..15
                3.1.5.4. Overlay Tunneling .........................16
    3.2. Multihoming ...............................................16
    3.3. VM Mobility ...............................................17
 4. Key Aspects of Overlay Networks ................................17
    4.1. Pros and Cons .............................................18
    4.2. Overlay Issues to Consider ................................19
         4.2.1. Data Plane vs. Control Plane Driven ................19
         4.2.2. Coordination between Data Plane and Control Plane ..19
         4.2.3. Handling Broadcast, Unknown Unicast, and
                Multicast (BUM) Traffic ............................20
         4.2.4. Path MTU ...........................................20
         4.2.5. NVE Location Trade-Offs ............................21
         4.2.6. Interaction between Network Overlays and
                Underlays ..........................................22
 5. Security Considerations ........................................22
 6. Informative References .........................................24
 Acknowledgments ...................................................26
 Authors' Addresses ................................................26

Lasserre, et al. Informational [Page 3] RFC 7365 Framework for DC Network Virtualization October 2014

1. Introduction

 This document provides a framework for Data Center (DC) Network
 Virtualization over Layer 3 (NVO3) tunnels.  This framework is
 intended to aid in standardizing protocols and mechanisms to support
 large-scale network virtualization for data centers.
 [RFC7364] defines the rationale for using overlay networks in order
 to build large multi-tenant data center networks.  Compute, storage
 and network virtualization are often used in these large data centers
 to support a large number of communication domains and end systems.
 This document provides reference models and functional components of
 data center overlay networks as well as a discussion of technical
 issues that have to be addressed.

1.1. General Terminology

 This document uses the following terminology:
 NVO3 Network: An overlay network that provides a Layer 2 (L2) or
 Layer 3 (L3) service to Tenant Systems over an L3 underlay network
 using the architecture and protocols as defined by the NVO3 Working
 Group.
 Network Virtualization Edge (NVE): An NVE is the network entity that
 sits at the edge of an underlay network and implements L2 and/or L3
 network virtualization functions.  The network-facing side of the NVE
 uses the underlying L3 network to tunnel tenant frames to and from
 other NVEs.  The tenant-facing side of the NVE sends and receives
 Ethernet frames to and from individual Tenant Systems.  An NVE could
 be implemented as part of a virtual switch within a hypervisor, a
 physical switch or router, or a Network Service Appliance, or it
 could be split across multiple devices.
 Virtual Network (VN): A VN is a logical abstraction of a physical
 network that provides L2 or L3 network services to a set of Tenant
 Systems.  A VN is also known as a Closed User Group (CUG).
 Virtual Network Instance (VNI): A specific instance of a VN from the
 perspective of an NVE.
 Virtual Network Context (VN Context) Identifier: Field in an overlay
 encapsulation header that identifies the specific VN the packet
 belongs to.  The egress NVE uses the VN Context identifier to deliver
 the packet to the correct Tenant System.  The VN Context identifier
 can be a locally significant identifier or a globally unique
 identifier.

Lasserre, et al. Informational [Page 4] RFC 7365 Framework for DC Network Virtualization October 2014

 Underlay or Underlying Network: The network that provides the
 connectivity among NVEs and that NVO3 packets are tunneled over,
 where an NVO3 packet carries an NVO3 overlay header followed by a
 tenant packet.  The underlay network does not need to be aware that
 it is carrying NVO3 packets.  Addresses on the underlay network
 appear as "outer addresses" in encapsulated NVO3 packets.  In
 general, the underlay network can use a completely different protocol
 (and address family) from that of the overlay.  In the case of NVO3,
 the underlay network is IP.
 Data Center (DC): A physical complex housing physical servers,
 network switches and routers, network service appliances, and
 networked storage.  The purpose of a data center is to provide
 application, compute, and/or storage services.  One such service is
 virtualized infrastructure data center services, also known as
 "Infrastructure as a Service".
 Virtual Data Center (Virtual DC): A container for virtualized
 compute, storage, and network services.  A virtual DC is associated
 with a single tenant and can contain multiple VNs and Tenant Systems
 connected to one or more of these VNs.
 Virtual Machine (VM): A software implementation of a physical machine
 that runs programs as if they were executing on a physical, non-
 virtualized machine.  Applications (generally) do not know they are
 running on a VM as opposed to running on a "bare metal" host or
 server, though some systems provide a para-virtualization environment
 that allows an operating system or application to be aware of the
 presence of virtualization for optimization purposes.
 Hypervisor: Software running on a server that allows multiple VMs to
 run on the same physical server.  The hypervisor manages and provides
 shared computation, memory, and storage services and network
 connectivity to the VMs that it hosts.  Hypervisors often embed a
 virtual switch (see below).
 Server: A physical end-host machine that runs user applications.  A
 standalone (or "bare metal") server runs a conventional operating
 system hosting a single-tenant application.  A virtualized server
 runs a hypervisor supporting one or more VMs.
 Virtual Switch (vSwitch): A function within a hypervisor (typically
 implemented in software) that provides similar forwarding services to
 a physical Ethernet switch.  A vSwitch forwards Ethernet frames
 between VMs running on the same server or between a VM and a physical
 Network Interface Card (NIC) connecting the server to a physical
 Ethernet switch or router.  A vSwitch also enforces network isolation
 between VMs that by policy are not permitted to communicate with each

Lasserre, et al. Informational [Page 5] RFC 7365 Framework for DC Network Virtualization October 2014

 other (e.g., by honoring VLANs).  A vSwitch may be bypassed when an
 NVE is enabled on the host server.
 Tenant: The customer using a virtual network and any associated
 resources (e.g., compute, storage, and network).  A tenant could be
 an enterprise or a department/organization within an enterprise.
 Tenant System: A physical or virtual system that can play the role of
 a host or a forwarding element such as a router, switch, firewall,
 etc.  It belongs to a single tenant and connects to one or more VNs
 of that tenant.
 Tenant Separation: Refers to isolating traffic of different tenants
 such that traffic from one tenant is not visible to or delivered to
 another tenant, except when allowed by policy.  Tenant separation
 also refers to address space separation, whereby different tenants
 can use the same address space without conflict.
 Virtual Access Points (VAPs): A logical connection point on the NVE
 for connecting a Tenant System to a virtual network.  Tenant Systems
 connect to VNIs at an NVE through VAPs.  VAPs can be physical ports
 or virtual ports identified through logical interface identifiers
 (e.g., VLAN ID or internal vSwitch Interface ID connected to a VM).
 End Device: A physical device that connects directly to the DC
 underlay network.  This is in contrast to a Tenant System, which
 connects to a corresponding tenant VN.  An End Device is administered
 by the DC operator rather than a tenant and is part of the DC
 infrastructure.  An End Device may implement NVO3 technology in
 support of NVO3 functions.  Examples of an End Device include hosts
 (e.g., server or server blade), storage systems (e.g., file servers
 and iSCSI storage systems), and network devices (e.g., firewall,
 load-balancer, and IPsec gateway).
 Network Virtualization Authority (NVA): Entity that provides
 reachability and forwarding information to NVEs.

Lasserre, et al. Informational [Page 6] RFC 7365 Framework for DC Network Virtualization October 2014

1.2. DC Network Architecture

 A generic architecture for data centers is depicted in Figure 1:
                              ,---------.
                            ,'           `.
                           (  IP/MPLS WAN )
                            `.           ,'
                              `-+------+'
                               \      /
                        +--------+   +--------+
                        |   DC   |+-+|   DC   |
                        |gateway |+-+|gateway |
                        +--------+   +--------+
                              |       /
                              .--. .--.
                            (    '    '.--.
                          .-.' Intra-DC     '
                         (     network      )
                          (             .'-'
                           '--'._.'.    )\ \
                           / /     '--'  \ \
                          / /      | |    \ \
                 +--------+   +--------+   +--------+
                 | access |   | access |   | access |
                 | switch |   | switch |   | switch |
                 +--------+   +--------+   +--------+
                    /     \    /    \     /      \
                 __/_      \  /      \   /_      _\__
           '--------'   '--------'   '--------'   '--------'
           :  End   :   :  End   :   :  End   :   :  End   :
           : Device :   : Device :   : Device :   : Device :
           '--------'   '--------'   '--------'   '--------'
           Figure 1: A Generic Architecture for Data Centers
 An example of multi-tier DC network architecture is presented in
 Figure 1.  It provides a view of the physical components inside a DC.
 A DC network is usually composed of intra-DC networks and network
 services, and inter-DC network and network connectivity services.
 DC networking elements can act as strict L2 switches and/or provide
 IP routing capabilities, including network service virtualization.
 In some DC architectures, some tier layers could provide L2 and/or L3
 services.  In addition, some tier layers may be collapsed, and
 Internet connectivity, inter-DC connectivity, and VPN support may be

Lasserre, et al. Informational [Page 7] RFC 7365 Framework for DC Network Virtualization October 2014

 handled by a smaller number of nodes.  Nevertheless, one can assume
 that the network functional blocks in a DC fit in the architecture
 depicted in Figure 1.
 The following components can be present in a DC:
  1. Access switch: Hardware-based Ethernet switch aggregating all

Ethernet links from the End Devices in a rack representing the

    entry point in the physical DC network for the hosts.  It may also
    provide routing functionality, virtual IP network connectivity, or
    Layer 2 tunneling over IP, for instance.  Access switches are
    usually multihomed to aggregation switches in the Intra-DC
    network.  A typical example of an access switch is a Top-of-Rack
    (ToR) switch.  Other deployment scenarios may use an intermediate
    Blade Switch before the ToR, or an End-of-Row (EoR) switch, to
    provide similar functions to a ToR.
  1. Intra-DC Network: Network composed of high-capacity core nodes

(Ethernet switches/routers). Core nodes may provide virtual

    Ethernet bridging and/or IP routing services.
  1. DC Gateway (DC GW): Gateway to the outside world providing DC

interconnect and connectivity to Internet and VPN customers. In

    the current DC network model, this may be simply a router
    connected to the Internet and/or an IP VPN/L2VPN PE.  Some network
    implementations may dedicate DC GWs for different connectivity
    types (e.g., a DC GW for Internet and another for VPN).
 Note that End Devices may be single-homed or multihomed to access
 switches.

2. Reference Models

2.1. Generic Reference Model

 Figure 2 depicts a DC reference model for network virtualization
 overlays where NVEs provide a logical interconnect between Tenant
 Systems that belong to a specific VN.

Lasserre, et al. Informational [Page 8] RFC 7365 Framework for DC Network Virtualization October 2014

       +--------+                                    +--------+
       | Tenant +--+                            +----| Tenant |
       | System |  |                           (')   | System |
       +--------+  |    .................     (   )  +--------+
                   |  +---+           +---+    (_)
                   +--|NVE|---+   +---|NVE|-----+
                      +---+   |   |   +---+
                      / .    +-----+      .
                     /  . +--| NVA |--+   .
                    /   . |  +-----+   \  .
                   |    . |             \ .
                   |    . |   Overlay   +--+--++--------+
       +--------+  |    . |   Network   | NVE || Tenant |
       | Tenant +--+    . |             |     || System |
       | System |       .  \ +---+      +--+--++--------+
       +--------+       .....|NVE|.........
                             +---+
                               |
                               |
                     =====================
                       |               |
                   +--------+      +--------+
                   | Tenant |      | Tenant |
                   | System |      | System |
                   +--------+      +--------+
    Figure 2: Generic Reference Model for DC Network Virtualization
                               Overlays
 In order to obtain reachability information, NVEs may exchange
 information directly between themselves via a control-plane protocol.
 In this case, a control-plane module resides in every NVE.
 It is also possible for NVEs to communicate with an external Network
 Virtualization Authority (NVA) to obtain reachability and forwarding
 information.  In this case, a protocol is used between NVEs and
 NVA(s) to exchange information.
 It should be noted that NVAs may be organized in clusters for
 redundancy and scalability and can appear as one logically
 centralized controller.  In this case, inter-NVA communication is
 necessary to synchronize state among nodes within a cluster or share
 information across clusters.  The information exchanged between NVAs
 of the same cluster could be different from the information exchanged
 across clusters.

Lasserre, et al. Informational [Page 9] RFC 7365 Framework for DC Network Virtualization October 2014

 A Tenant System can be attached to an NVE in several ways:
  1. locally, by being co-located in the same End Device
  1. remotely, via a point-to-point connection or a switched network
 When an NVE is co-located with a Tenant System, the state of the
 Tenant System can be determined without protocol assistance.  For
 instance, the operational status of a VM can be communicated via a
 local API.  When an NVE is remotely connected to a Tenant System, the
 state of the Tenant System or NVE needs to be exchanged directly or
 via a management entity, using a control-plane protocol or API, or
 directly via a data-plane protocol.
 The functional components in Figure 2 do not necessarily map directly
 to the physical components described in Figure 1.  For example, an
 End Device can be a server blade with VMs and a virtual switch.  A VM
 can be a Tenant System, and the NVE functions may be performed by the
 host server.  In this case, the Tenant System and NVE function are
 co-located.  Another example is the case where the End Device is the
 Tenant System and the NVE function can be implemented by the
 connected ToR.  In this case, the Tenant System and NVE function are
 not co-located.
 Underlay nodes utilize L3 technologies to interconnect NVE nodes.
 These nodes perform forwarding based on outer L3 header information,
 and generally do not maintain state for each tenant service, albeit
 some applications (e.g., multicast) may require control-plane or
 forwarding-plane information that pertains to a tenant, group of
 tenants, tenant service, or a set of services that belong to one or
 more tenants.  Mechanisms to control the amount of state maintained
 in the underlay may be needed.

2.2. NVE Reference Model

 Figure 3 depicts the NVE reference model.  One or more VNIs can be
 instantiated on an NVE.  A Tenant System interfaces with a
 corresponding VNI via a VAP.  An overlay module provides tunneling
 overlay functions (e.g., encapsulation and decapsulation of tenant
 traffic, tenant identification, and mapping, etc.).

Lasserre, et al. Informational [Page 10] RFC 7365 Framework for DC Network Virtualization October 2014

                   +-------- L3 Network -------+
                   |                           |
                   |        Tunnel Overlay     |
       +------------+---------+       +---------+------------+
       | +----------+-------+ |       | +---------+--------+ |
       | |  Overlay Module  | |       | |  Overlay Module  | |
       | +---------+--------+ |       | +---------+--------+ |
       |           |VN Context|       | VN Context|          |
       |           |          |       |           |          |
       |  +--------+-------+  |       |  +--------+-------+  |
       |  | |VNI|   .  |VNI|  |       |  | |VNI|   .  |VNI|  |
  NVE1 |  +-+------------+-+  |       |  +-+-----------+--+  | NVE2
       |    |   VAPs     |    |       |    |    VAPs   |     |
       +----+------------+----+       +----+-----------+-----+
            |            |                 |           |
            |            |                 |           |
           Tenant Systems                 Tenant Systems
                Figure 3: Generic NVE Reference Model
 Note that some NVE functions (e.g., data-plane and control-plane
 functions) may reside in one device or may be implemented separately
 in different devices.

2.3. NVE Service Types

 An NVE provides different types of virtualized network services to
 multiple tenants, i.e., an L2 service or an L3 service.  Note that an
 NVE may be capable of providing both L2 and L3 services for a tenant.
 This section defines the service types and associated attributes.

2.3.1. L2 NVE Providing Ethernet LAN-Like Service

 An L2 NVE implements Ethernet LAN emulation, an Ethernet-based
 multipoint service similar to an IETF Virtual Private LAN Service
 (VPLS) [RFC4761][RFC4762] or Ethernet VPN [EVPN] service, where the
 Tenant Systems appear to be interconnected by a LAN environment over
 an L3 overlay.  As such, an L2 NVE provides per-tenant virtual
 switching instance (L2 VNI) and L3 (IP/MPLS) tunneling encapsulation
 of tenant Media Access Control (MAC) frames across the underlay.
 Note that the control plane for an L2 NVE could be implemented
 locally on the NVE or in a separate control entity.

2.3.2. L3 NVE Providing IP/VRF-Like Service

 An L3 NVE provides virtualized IP forwarding service, similar to IETF
 IP VPN (e.g., BGP/MPLS IP VPN [RFC4364]) from a service definition
 perspective.  That is, an L3 NVE provides per-tenant forwarding and

Lasserre, et al. Informational [Page 11] RFC 7365 Framework for DC Network Virtualization October 2014

 routing instance (L3 VNI) and L3 (IP/MPLS) tunneling encapsulation of
 tenant IP packets across the underlay.  Note that routing could be
 performed locally on the NVE or in a separate control entity.

2.4. Operational Management Considerations

 NVO3 services are overlay services over an IP underlay.
 As far as the IP underlay is concerned, existing IP Operations,
 Administration, and Maintenance (OAM) facilities are used.
 With regard to the NVO3 overlay, both L2 and L3 services can be
 offered.  It is expected that existing fault and performance OAM
 facilities will be used.  Sections 4.1 and 4.2.6 provide further
 discussion of additional fault and performance management issues to
 consider.
 As far as configuration is concerned, the DC environment is driven by
 the need to bring new services up rapidly and is typically very
 dynamic, specifically in the context of virtualized services.  It is
 therefore critical to automate the configuration of NVO3 services.

3. Functional Components

 This section decomposes the network virtualization architecture into
 the functional components described in Figure 3 to make it easier to
 discuss solution options for these components.

3.1. Service Virtualization Components

3.1.1. Virtual Access Points (VAPs)

 Tenant Systems are connected to VNIs through Virtual Access Points
 (VAPs).
 VAPs can be physical ports or virtual ports identified through
 logical interface identifiers (e.g., VLAN ID and internal vSwitch
 Interface ID connected to a VM).

3.1.2. Virtual Network Instance (VNI)

 A VNI is a specific VN instance on an NVE.  Each VNI defines a
 forwarding context that contains reachability information and
 policies.

Lasserre, et al. Informational [Page 12] RFC 7365 Framework for DC Network Virtualization October 2014

3.1.3. Overlay Modules and VN Context

 Mechanisms for identifying each tenant service are required to allow
 the simultaneous overlay of multiple tenant services over the same
 underlay L3 network topology.  In the data plane, each NVE, upon
 sending a tenant packet, must be able to encode the VN Context for
 the destination NVE in addition to the L3 tunneling information
 (e.g., source IP address identifying the source NVE and the
 destination IP address identifying the destination NVE, or MPLS
 label).  This allows the destination NVE to identify the tenant
 service instance and therefore appropriately process and forward the
 tenant packet.
 The overlay module provides tunneling overlay functions: tunnel
 initiation/termination as in the case of stateful tunnels (see
 Section 3.1.4) and/or encapsulation/decapsulation of frames from the
 VAPs/L3 underlay.
 In a multi-tenant context, tunneling aggregates frames from/to
 different VNIs.  Tenant identification and traffic demultiplexing are
 based on the VN Context identifier.
 The following approaches can be considered:
  1. VN Context identifier per Tenant: This is a globally unique (on a

per-DC administrative domain) VN identifier used to identify the

    corresponding VNI.  Examples of such identifiers in existing
    technologies are IEEE VLAN IDs and Service Instance IDs (I-SIDs)
    that identify virtual L2 domains when using IEEE 802.1Q and IEEE
    802.1ah, respectively.  Note that multiple VN identifiers can
    belong to a tenant.
  1. One VN Context identifier per VNI: Each VNI value is automatically

generated by the egress NVE, or a control plane associated with

    that NVE, and usually distributed by a control-plane protocol to
    all the related NVEs.  An example of this approach is the use of
    per-VRF MPLS labels in IP VPN [RFC4364].  The VNI value is
    therefore locally significant to the egress NVE.
  1. One VN Context identifier per VAP: A value locally significant to

an NVE is assigned and usually distributed by a control-plane

    protocol to identify a VAP.  An example of this approach is the
    use of per-CE MPLS labels in IP VPN [RFC4364].
 Note that when using one VN Context per VNI or per VAP, an additional
 global identifier (e.g., a VN identifier or name) may be used by the
 control plane to identify the tenant context.

Lasserre, et al. Informational [Page 13] RFC 7365 Framework for DC Network Virtualization October 2014

3.1.4. Tunnel Overlays and Encapsulation Options

 Once the VN Context identifier is added to the frame, an L3 tunnel
 encapsulation is used to transport the frame to the destination NVE.
 Different IP tunneling options (e.g., Generic Routing Encapsulation
 (GRE), the Layer 2 Tunneling Protocol (L2TP), and IPsec) and MPLS
 tunneling can be used.  Tunneling could be stateless or stateful.
 Stateless tunneling simply entails the encapsulation of a tenant
 packet with another header necessary for forwarding the packet across
 the underlay (e.g., IP tunneling over an IP underlay).  Stateful
 tunneling, on the other hand, entails maintaining tunneling state at
 the tunnel endpoints (i.e., NVEs).  Tenant packets on an ingress NVE
 can then be transmitted over such tunnels to a destination (egress)
 NVE by encapsulating the packets with a corresponding tunneling
 header.  The tunneling state at the endpoints may be configured or
 dynamically established.  Solutions should specify the tunneling
 technology used and whether it is stateful or stateless.  In this
 document, however, tunneling and tunneling encapsulation are used
 interchangeably to simply mean the encapsulation of a tenant packet
 with a tunneling header necessary to carry the packet between an
 ingress NVE and an egress NVE across the underlay.  It should be
 noted that stateful tunneling, especially when configuration is
 involved, does impose management overhead and scale constraints.
 When confidentiality is required, the use of opportunistic security
 [OPPSEC] can be used as a stateless tunneling solution.

3.1.5. Control-Plane Components

3.1.5.1. Distributed vs. Centralized Control Plane

 Control- and management-plane entities can be centralized or
 distributed.  Both approaches have been used extensively in the past.
 The routing model of the Internet is a good example of a distributed
 approach.  Transport networks have usually used a centralized
 approach to manage transport paths.
 It is also possible to combine the two approaches, i.e., using a
 hybrid model.  A global view of network state can have many benefits,
 but it does not preclude the use of distributed protocols within the
 network.  Centralized models provide a facility to maintain global
 state and distribute that state to the network.  When used in
 combination with distributed protocols, greater network efficiencies,
 improved reliability, and robustness can be achieved.  Domain- and/or
 deployment-specific constraints define the balance between
 centralized and distributed approaches.

Lasserre, et al. Informational [Page 14] RFC 7365 Framework for DC Network Virtualization October 2014

3.1.5.2. Auto-provisioning and Service Discovery

 NVEs must be able to identify the appropriate VNI for each Tenant
 System.  This is based on state information that is often provided by
 external entities.  For example, in an environment where a VM is a
 Tenant System, this information is provided by VM orchestration
 systems, since these are the only entities that have visibility of
 which VM belongs to which tenant.
 A mechanism for communicating this information to the NVE is
 required.  VAPs have to be created and mapped to the appropriate VNI.
 Depending upon the implementation, this control interface can be
 implemented using an auto-discovery protocol between Tenant Systems
 and their local NVE or through management entities.  In either case,
 appropriate security and authentication mechanisms to verify that
 Tenant System information is not spoofed or altered are required.
 This is one critical aspect for providing integrity and tenant
 isolation in the system.
 NVEs may learn reachability information for VNIs on other NVEs via a
 control protocol that exchanges such information among NVEs or via a
 management-control entity.

3.1.5.3. Address Advertisement and Tunnel Mapping

 As traffic reaches an ingress NVE on a VAP, a lookup is performed to
 determine which NVE or local VAP the packet needs to be sent to.  If
 the packet is to be sent to another NVE, the packet is encapsulated
 with a tunnel header containing the destination information
 (destination IP address or MPLS label) of the egress NVE.
 Intermediate nodes (between the ingress and egress NVEs) switch or
 route traffic based upon the tunnel destination information.
 A key step in the above process consists of identifying the
 destination NVE the packet is to be tunneled to.  NVEs are
 responsible for maintaining a set of forwarding or mapping tables
 that hold the bindings between destination VM and egress NVE
 addresses.  Several ways of populating these tables are possible:
 control plane driven, management plane driven, or data plane driven.
 When a control-plane protocol is used to distribute address
 reachability and tunneling information, the auto-provisioning and
 service discovery could be accomplished by the same protocol.  In
 this scenario, the auto-provisioning and service discovery could be
 combined with (be inferred from) the address advertisement and
 associated tunnel mapping.  Furthermore, a control-plane protocol

Lasserre, et al. Informational [Page 15] RFC 7365 Framework for DC Network Virtualization October 2014

 that carries both MAC and IP addresses eliminates the need for the
 Address Resolution Protocol (ARP) and hence addresses one of the
 issues with explosive ARP handling as discussed in [RFC6820].

3.1.5.4. Overlay Tunneling

 For overlay tunneling, and dependent upon the tunneling technology
 used for encapsulating the Tenant System packets, it may be
 sufficient to have one or more local NVE addresses assigned and used
 in the source and destination fields of a tunneling encapsulation
 header.  Other information that is part of the tunneling
 encapsulation header may also need to be configured.  In certain
 cases, local NVE configuration may be sufficient while in other
 cases, some tunneling-related information may need to be shared among
 NVEs.  The information that needs to be shared will be technology
 dependent.  For instance, potential information could include tunnel
 identity, encapsulation type, and/or tunnel resources.  In certain
 cases, such as when using IP multicast in the underlay, tunnels that
 interconnect NVEs may need to be established.  When tunneling
 information needs to be exchanged or shared among NVEs, a control-
 plane protocol may be required.  For instance, it may be necessary to
 provide active/standby status information between NVEs, up/down
 status information, pruning/grafting information for multicast
 tunnels, etc.
 In addition, a control plane may be required to set up the tunnel
 path for some tunneling technologies.  This applies to both unicast
 and multicast tunneling.

3.2. Multihoming

 Multihoming techniques can be used to increase the reliability of an
 NVO3 network.  It is also important to ensure that the physical
 diversity in an NVO3 network is taken into account to avoid single
 points of failure.
 Multihoming can be enabled in various nodes, from Tenant Systems into
 ToRs, ToRs into core switches/routers, and core nodes into DC GWs.
 The NVO3 underlay nodes (i.e., from NVEs to DC GWs) rely on IP
 routing techniques or MPLS re-rerouting capabilities as the means to
 re-route traffic upon failures.
 When a Tenant System is co-located with the NVE, the Tenant System is
 effectively single-homed to the NVE via a virtual port.  When the
 Tenant System and the NVE are separated, the Tenant System is
 connected to the NVE via a logical L2 construct such as a VLAN, and
 it can be multihomed to various NVEs.  An NVE may provide an L2

Lasserre, et al. Informational [Page 16] RFC 7365 Framework for DC Network Virtualization October 2014

 service to the end system or an l3 service.  An NVE may be multihomed
 to a next layer in the DC at L2 or L3.  When an NVE provides an L2
 service and is not co-located with the end system, loop-avoidance
 techniques must be used.  Similarly, when the NVE provides L3
 service, similar dual-homing techniques can be used.  When the NVE
 provides an L3 service to the end system, it is possible that no
 dynamic routing protocol is enabled between the end system and the
 NVE.  The end system can be multihomed to multiple physically
 separated L3 NVEs over multiple interfaces.  When one of the links
 connected to an NVE fails, the other interfaces can be used to reach
 the end system.
 External connectivity from a DC can be handled by two or more DC
 gateways.  Each gateway provides access to external networks such as
 VPNs or the Internet.  A gateway may be connected to two or more edge
 nodes in the external network for redundancy.  When a connection to
 an upstream node is lost, the alternative connection is used, and the
 failed route withdrawn.

3.3. VM Mobility

 In DC environments utilizing VM technologies, an important feature is
 that VMs can move from one server to another server in the same or
 different L2 physical domains (within or across DCs) in a seamless
 manner.
 A VM can be moved from one server to another in stopped or suspended
 state ("cold" VM mobility) or in running/active state ("hot" VM
 mobility).  With "hot" mobility, VM L2 and L3 addresses need to be
 preserved.  With "cold" mobility, it may be desired to preserve at
 least VM L3 addresses.
 Solutions to maintain connectivity while a VM is moved are necessary
 in the case of "hot" mobility.  This implies that connectivity among
 VMs is preserved.  For instance, for L2 VNs, ARP caches are updated
 accordingly.
 Upon VM mobility, NVE policies that define connectivity among VMs
 must be maintained.
 During VM mobility, it is expected that the path to the VM's default
 gateway assures adequate QoS to VM applications, i.e., QoS that
 matches the expected service-level agreement for these applications.

4. Key Aspects of Overlay Networks

 The intent of this section is to highlight specific issues that
 proposed overlay solutions need to address.

Lasserre, et al. Informational [Page 17] RFC 7365 Framework for DC Network Virtualization October 2014

4.1. Pros and Cons

 An overlay network is a layer of virtual network topology on top of
 the physical network.
 Overlay networks offer the following key advantages:
  1. Unicast tunneling state management and association of Tenant

Systems reachability are handled at the edge of the network (at

    the NVE).  Intermediate transport nodes are unaware of such state.
    Note that when multicast is enabled in the underlay network to
    build multicast trees for tenant VNs, there would be more state
    related to tenants in the underlay core network.
  1. Tunneling is used to aggregate traffic and hide tenant addresses

from the underlay network and hence offers the advantage of

    minimizing the amount of forwarding state required within the
    underlay network.
  1. Decoupling of the overlay addresses (MAC and IP) used by VMs from

the underlay network provides tenant separation and separation of

    the tenant address spaces from the underlay address space.
  1. Overlay networks support of a large number of virtual network

identifiers.

 Overlay networks also create several challenges:
  1. Overlay networks typically have no control of underlay networks

and lack underlay network information (e.g., underlay

    utilization):
    o  Overlay networks and/or their associated management entities
       typically probe the network to measure link or path properties,
       such as available bandwidth or packet loss rate.  It is
       difficult to accurately evaluate network properties.  It might
       be preferable for the underlay network to expose usage and
       performance information.
    o  Miscommunication or lack of coordination between overlay and
       underlay networks can lead to an inefficient usage of network
       resources.
    o  When multiple overlays co-exist on top of a common underlay
       network, the lack of coordination between overlays can lead to
       performance issues and/or resource usage inefficiencies.

Lasserre, et al. Informational [Page 18] RFC 7365 Framework for DC Network Virtualization October 2014

  1. Traffic carried over an overlay might fail to traverse firewalls

and NAT devices.

  1. Multicast service scalability: Multicast support may be required

in the underlay network to address tenant flood containment or

    efficient multicast handling.  The underlay may also be required
    to maintain multicast state on a per-tenant basis or even on a
    per-individual multicast flow of a given tenant.  Ingress
    replication at the NVE eliminates that additional multicast state
    in the underlay core, but depending on the multicast traffic
    volume, it may cause inefficient use of bandwidth.

4.2. Overlay Issues to Consider

4.2.1. Data Plane vs. Control Plane Driven

 In the case of an L2 NVE, it is possible to dynamically learn MAC
 addresses against VAPs.  It is also possible that such addresses be
 known and controlled via management or a control protocol for both L2
 NVEs and L3 NVEs.  Dynamic data-plane learning implies that flooding
 of unknown destinations be supported and hence implies that broadcast
 and/or multicast be supported or that ingress replication be used as
 described in Section 4.2.3.  Multicasting in the underlay network for
 dynamic learning may lead to significant scalability limitations.
 Specific forwarding rules must be enforced to prevent loops from
 happening.  This can be achieved using a spanning tree, a shortest
 path tree, or a split-horizon mesh.
 It should be noted that the amount of state to be distributed is
 dependent upon network topology and the number of virtual machines.
 Different forms of caching can also be utilized to minimize state
 distribution between the various elements.  The control plane should
 not require an NVE to maintain the locations of all the Tenant
 Systems whose VNs are not present on the NVE.  The use of a control
 plane does not imply that the data plane on NVEs has to maintain all
 the forwarding state in the control plane.

4.2.2. Coordination between Data Plane and Control Plane

 For an L2 NVE, the NVE needs to be able to determine MAC addresses of
 the Tenant Systems connected via a VAP.  This can be achieved via
 data-plane learning or a control plane.  For an L3 NVE, the NVE needs
 to be able to determine the IP addresses of the Tenant Systems
 connected via a VAP.

Lasserre, et al. Informational [Page 19] RFC 7365 Framework for DC Network Virtualization October 2014

 In both cases, coordination with the NVE control protocol is needed
 such that when the NVE determines that the set of addresses behind a
 VAP has changed, it triggers the NVE control plane to distribute this
 information to its peers.

4.2.3. Handling Broadcast, Unknown Unicast, and Multicast (BUM) Traffic

 There are several options to support packet replication needed for
 broadcast, unknown unicast, and multicast.  Typical methods include:
  1. Ingress replication
  1. Use of underlay multicast trees
 There is a bandwidth vs. state trade-off between the two approaches.
 Depending upon the degree of replication required (i.e., the number
 of hosts per group) and the amount of multicast state to maintain,
 trading bandwidth for state should be considered.
 When the number of hosts per group is large, the use of underlay
 multicast trees may be more appropriate.  When the number of hosts is
 small (e.g., 2-3) and/or the amount of multicast traffic is small,
 ingress replication may not be an issue.
 Depending upon the size of the data center network and hence the
 number of (S,G) entries, and also the duration of multicast flows,
 the use of underlay multicast trees can be a challenge.
 When flows are well known, it is possible to pre-provision such
 multicast trees.  However, it is often difficult to predict
 application flows ahead of time; hence, programming of (S,G) entries
 for short-lived flows could be impractical.
 A possible trade-off is to use in the underlay shared multicast trees
 as opposed to dedicated multicast trees.

4.2.4. Path MTU

 When using overlay tunneling, an outer header is added to the
 original frame.  This can cause the MTU of the path to the egress
 tunnel endpoint to be exceeded.
 It is usually not desirable to rely on IP fragmentation for
 performance reasons.  Ideally, the interface MTU as seen by a Tenant
 System is adjusted such that no fragmentation is needed.

Lasserre, et al. Informational [Page 20] RFC 7365 Framework for DC Network Virtualization October 2014

 It is possible for the MTU to be configured manually or to be
 discovered dynamically.  Various Path MTU discovery techniques exist
 in order to determine the proper MTU size to use:
  1. Classical ICMP-based Path MTU Discovery [RFC1191] [RFC1981]
    Tenant Systems rely on ICMP messages to discover the MTU of the
    end-to-end path to its destination.  This method is not always
    possible, such as when traversing middleboxes (e.g., firewalls)
    that disable ICMP for security reasons.
  1. Extended Path MTU Discovery techniques such as those defined in

[RFC4821]

    Tenant Systems send probe packets of different sizes and rely on
    confirmation of receipt or lack thereof from receivers to allow a
    sender to discover the MTU of the end-to-end paths.
 While it could also be possible to rely on the NVE to perform
 segmentation and reassembly operations without relying on the Tenant
 Systems to know about the end-to-end MTU, this would lead to
 undesired performance and congestion issues as well as significantly
 increase the complexity of hardware NVEs required for buffering and
 reassembly logic.
 Preferably, the underlay network should be designed in such a way
 that the MTU can accommodate the extra tunneling and possibly
 additional NVO3 header encapsulation overhead.

4.2.5. NVE Location Trade-Offs

 In the case of DC traffic, traffic originated from a VM is native
 Ethernet traffic.  This traffic can be switched by a local virtual
 switch or ToR switch and then by a DC gateway.  The NVE function can
 be embedded within any of these elements.
 There are several criteria to consider when deciding where the NVE
 function should happen:
  1. Processing and memory requirements
    o  Datapath (e.g., lookups, filtering, and
       encapsulation/decapsulation)
    o  Control-plane processing (e.g., routing, signaling, and OAM)
       and where specific control-plane functions should be enabled
  1. FIB/RIB size

Lasserre, et al. Informational [Page 21] RFC 7365 Framework for DC Network Virtualization October 2014

  1. Multicast support
    o  Routing/signaling protocols
    o  Packet replication capability
    o  Multicast FIB
  1. Fragmentation support
  1. QoS support (e.g., marking, policing, and queuing)
  1. Resiliency

4.2.6. Interaction between Network Overlays and Underlays

 When multiple overlays co-exist on top of a common underlay network,
 resources (e.g., bandwidth) should be provisioned to ensure that
 traffic from overlays can be accommodated and QoS objectives can be
 met.  Overlays can have partially overlapping paths (nodes and
 links).
 Each overlay is selfish by nature.  It sends traffic so as to
 optimize its own performance without considering the impact on other
 overlays, unless the underlay paths are traffic engineered on a per-
 overlay basis to avoid congestion of underlay resources.
 Better visibility between overlays and underlays, or general
 coordination in placing overlay demands on an underlay network, may
 be achieved by providing mechanisms to exchange performance and
 liveliness information between the underlay and overlay(s) or by the
 use of such information by a coordination system.  Such information
 may include:
  1. Performance metrics (throughput, delay, loss, jitter) such as

defined in [RFC3148], [RFC2679], [RFC2680], and [RFC3393].

  1. Cost metrics

5. Security Considerations

 There are three points of view when considering security for NVO3.
 First, the service offered by a service provider via NVO3 technology
 to a tenant must meet the mutually agreed security requirements.
 Second, a network implementing NVO3 must be able to trust the virtual
 network identity associated with packets received from a tenant.
 Third, an NVO3 network must consider the security associated with
 running as an overlay across the underlay network.

Lasserre, et al. Informational [Page 22] RFC 7365 Framework for DC Network Virtualization October 2014

 To meet a tenant's security requirements, the NVO3 service must
 deliver packets from the tenant to the indicated destination(s) in
 the overlay network and external networks.  The NVO3 service provides
 data confidentiality through data separation.  The use of both VNIs
 and tunneling of tenant traffic by NVEs ensures that NVO3 data is
 kept in a separate context and thus separated from other tenant
 traffic.  The infrastructure supporting an NVO3 service (e.g.,
 management systems, NVEs, NVAs, and intermediate underlay networks)
 should be limited to authorized access so that data integrity can be
 expected.  If a tenant requires that its data be confidential, then
 the Tenant System may choose to encrypt its data before transmission
 into the NVO3 service.
 An NVO3 service must be able to verify the VNI received on a packet
 from the tenant.  To ensure this, not only tenant data but also NVO3
 control data must be secured (e.g., control traffic between NVAs and
 NVEs, between NVAs, and between NVEs).  Since NVEs and NVAs play a
 central role in NVO3, it is critical that secure access to NVEs and
 NVAs be ensured such that no unauthorized access is possible.  As
 discussed in Section 3.1.5.2, identification of Tenant Systems is
 based upon state that is often provided by management systems (e.g.,
 a VM orchestration system in a virtualized environment).  Secure
 access to such management systems must also be ensured.  When an NVE
 receives data from a Tenant System, the tenant identity needs to be
 verified in order to guarantee that it is authorized to access the
 corresponding VN.  This can be achieved by identifying incoming
 packets against specific VAPs in some cases.  In other circumstances,
 authentication may be necessary.  Once this verification is done, the
 packet is allowed into the NVO3 overlay, and no integrity protection
 is provided on the overlay packet encapsulation (e.g., the VNI,
 destination NVE, etc.).
 Since an NVO3 service can run across diverse underlay networks, when
 the underlay network is not trusted to provide at least data
 integrity, data encryption is needed to assure correct packet
 delivery.
 It is also desirable to restrict the types of information (e.g.,
 topology information as discussed in Section 4.2.6) that can be
 exchanged between an NVO3 service and underlay networks based upon
 their agreed security requirements.

Lasserre, et al. Informational [Page 23] RFC 7365 Framework for DC Network Virtualization October 2014

6. Informative References

 [EVPN]     Sajassi, A., Aggarwal, R., Bitar, N., Isaac, A., and J.
            Uttaro, "BGP MPLS Based Ethernet VPN", Work in Progress,
            draft-ietf-l2vpn-evpn-10, October 2014.
 [OPPSEC]   Dukhovni, V. "Opportunistic Security: Some Protection Most
            of the Time", Work in Progress, draft-dukhovni-
            opportunistic-security-04, August 2014.
 [RFC1191]  Mogul, J. and S. Deering, "Path MTU discovery", RFC 1191,
            November 1990, <http://www.rfc-editor.org/info/rfc1191>.
 [RFC1981]  McCann, J., Deering, S., and J. Mogul, "Path MTU Discovery
            for IP version 6", RFC 1981, August 1996,
            <http://www.rfc-editor.org/info/rfc1981>.
 [RFC2679]  Almes, G., Kalidindi, S., and M. Zekauskas, "A One-way
            Delay Metric for IPPM", RFC 2679, September 1999,
            <http://www.rfc-editor.org/info/rfc2679>.
 [RFC2680]  Almes, G., Kalidindi, S., and M. Zekauskas, "A One-way
            Packet Loss Metric for IPPM", RFC 2680, September 1999,
            <http://www.rfc-editor.org/info/rfc2680>.
 [RFC3148]  Mathis, M. and M. Allman, "A Framework for Defining
            Empirical Bulk Transfer Capacity Metrics", RFC 3148, July
            2001, <http://www.rfc-editor.org/info/rfc3148>.
 [RFC3393]  Demichelis, C. and P. Chimento, "IP Packet Delay Variation
            Metric for IP Performance Metrics (IPPM)", RFC 3393,
            November 2002, <http://www.rfc-editor.org/info/rfc3393>.
 [RFC4364]  Rosen, E. and Y. Rekhter, "BGP/MPLS IP Virtual Private
            Networks (VPNs)", RFC 4364, February 2006,
            <http://www.rfc-editor.org/info/rfc4364>.
 [RFC4761]  Kompella, K., Ed., and Y. Rekhter, Ed., "Virtual Private
            LAN Service (VPLS) Using BGP for Auto-Discovery and
            Signaling", RFC 4761, January 2007,
            <http://www.rfc-editor.org/info/rfc4761>.
 [RFC4762]  Lasserre, M., Ed., and V. Kompella, Ed., "Virtual Private
            LAN Service (VPLS) Using Label Distribution Protocol (LDP)
            Signaling", RFC 4762, January 2007,
            <http://www.rfc-editor.org/info/rfc4762>.

Lasserre, et al. Informational [Page 24] RFC 7365 Framework for DC Network Virtualization October 2014

 [RFC4821]  Mathis, M. and J. Heffner, "Packetization Layer Path MTU
            Discovery", RFC 4821, March 2007,
            <http://www.rfc-editor.org/info/rfc4821>.
 [RFC6820]  Narten, T., Karir, M., and I. Foo, "Address Resolution
            Problems in Large Data Center Networks", RFC 6820, January
            2013, <http://www.rfc-editor.org/info/rfc6820>.
 [RFC7364]  Narten, T., Ed., Gray, E., Ed., Black, D., Fang, L.,
            Kreeger, L., and M. Napierala, "Problem Statement:
            Overlays for Network Virtualization", RFC 7364, October
            2014, <http://www.rfc-editor.org/info/rfc7364>.

Lasserre, et al. Informational [Page 25] RFC 7365 Framework for DC Network Virtualization October 2014

Acknowledgments

 In addition to the authors, the following people contributed to this
 document: Dimitrios Stiliadis, Rotem Salomonovitch, Lucy Yong, Thomas
 Narten, Larry Kreeger, and David Black.

Authors' Addresses

 Marc Lasserre
 Alcatel-Lucent
 EMail: marc.lasserre@alcatel-lucent.com
 Florin Balus
 Alcatel-Lucent
 777 E. Middlefield Road
 Mountain View, CA 94043
 United States
 EMail: florin.balus@alcatel-lucent.com
 Thomas Morin
 Orange
 EMail: thomas.morin@orange.com
 Nabil Bitar
 Verizon
 50 Sylvan Road
 Waltham, MA 02145
 United States
 EMail: nabil.n.bitar@verizon.com
 Yakov Rekhter
 Juniper
 EMail: yakov@juniper.net

Lasserre, et al. Informational [Page 26]