Internet Engineering Task Force (IETF) Z. Liu Request for Comments: 7309 China Telecom Category: Standards Track L. Jin ISSN: 2070-1721

                                                               R. Chen
                                                       ZTE Corporation
                                                                D. Cai
                                                              S. Salam
                                                                 Cisco
                                                             July 2014
         Redundancy Mechanism for Inter-domain VPLS Service

Abstract

 In many existing Virtual Private LAN Service (VPLS) inter-domain
 deployments (based on RFC 4762), pseudowire (PW) connectivity offers
 no Provider Edge (PE) node redundancy, or offers PE node redundancy
 with only a single domain.  This deployment approach incurs a high
 risk of service interruption, since at least one domain will not
 offer PE node redundancy.  This document describes an inter-domain
 VPLS solution that provides PE node redundancy across domains.

Status of This Memo

 This is an Internet Standards Track document.
 This document is a product of the Internet Engineering Task Force
 (IETF).  It represents the consensus of the IETF community.  It has
 received public review and has been approved for publication by the
 Internet Engineering Steering Group (IESG).  Further information on
 Internet Standards is available in Section 2 of RFC 5741.
 Information about the current status of this document, any errata,
 and how to provide feedback on it may be obtained at
 http://www.rfc-editor.org/info/rfc7309.

Liu, et al. Standards Track [Page 1] RFC 7309 Redundancy for VPLS Inter-domain July 2014

Copyright Notice

 Copyright (c) 2014 IETF Trust and the persons identified as the
 document authors.  All rights reserved.
 This document is subject to BCP 78 and the IETF Trust's Legal
 Provisions Relating to IETF Documents
 (http://trustee.ietf.org/license-info) in effect on the date of
 publication of this document.  Please review these documents
 carefully, as they describe your rights and restrictions with respect
 to this document.  Code Components extracted from this document must
 include Simplified BSD License text as described in Section 4.e of
 the Trust Legal Provisions and are provided without warranty as
 described in the Simplified BSD License.

Table of Contents

 1.  Introduction  . . . . . . . . . . . . . . . . . . . . . . . .   3
 2.  Conventions Used in This Document . . . . . . . . . . . . . .   3
 3.  Motivation  . . . . . . . . . . . . . . . . . . . . . . . . .   3
 4.  Network Use Case  . . . . . . . . . . . . . . . . . . . . . .   4
 5.   PW Redundancy Application Procedure for Inter-domain
     Redundancy  . . . . . . . . . . . . . . . . . . . . . . . . .   6
   5.1.  ICCP Switchover Condition . . . . . . . . . . . . . . . .   6
     5.1.1.  Inter-domain PW Failure . . . . . . . . . . . . . . .   6
     5.1.2.  PE Node Isolation . . . . . . . . . . . . . . . . . .   6
     5.1.3.  PE Node Failure . . . . . . . . . . . . . . . . . . .   6
   5.2.  Inter-domain Redundancy with Two PWs  . . . . . . . . . .   6
   5.3.  Inter-domain Redundancy with Four PWs . . . . . . . . . .   7
 6.  Management Considerations . . . . . . . . . . . . . . . . . .   9
 7.  Security Considerations . . . . . . . . . . . . . . . . . . .   9
 8.  Acknowledgements  . . . . . . . . . . . . . . . . . . . . . .  10
 9.  Contributors  . . . . . . . . . . . . . . . . . . . . . . . .  10
 10. References  . . . . . . . . . . . . . . . . . . . . . . . . .  10
   10.1.  Normative references . . . . . . . . . . . . . . . . . .  10
   10.2.  Informative references . . . . . . . . . . . . . . . . .  10

Liu, et al. Standards Track [Page 2] RFC 7309 Redundancy for VPLS Inter-domain July 2014

1. Introduction

 In many existing Virtual Private LAN Service (VPLS) deployments based
 on [RFC4762], pseudowire (PW) connectivity offers no Provider Edge
 (PE) node redundancy, or offers PE node redundancy with only a single
 domain.  This deployment approach incurs a high risk of service
 interruption, since at least one domain will not offer PE node
 redundancy.  This document describes an inter-domain VPLS solution
 that provides PE node redundancy across domains.  The redundancy
 mechanism will provide PE node redundancy and link redundancy in both
 domains.  The PE throughout the document refers to a routing and
 bridging capable PE defined in [RFC4762], Section 10.  The domain in
 this document refers to an autonomous system (AS), or other
 administrative domains.
 The solution relies on the use of the Inter-Chassis Communication
 Protocol (ICCP) [RFC7275] to coordinate between the two redundant
 edge nodes, and use of PW Preferential Forwarding Status Bit
 [RFC6870] to negotiate the PW status.  There is no change to any
 protocol message formats and no new protocol options are introduced.
 This solution is a description of reusing existing protocol building
 blocks to achieve the desired function, but also defines
 implementation behavior necessary for the function to work.

2. Conventions Used in This Document

 The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
 "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY", and "OPTIONAL" in this
 document are to be interpreted as described in [RFC2119].

3. Motivation

 Inter-AS VPLS offerings are widely deployed in service provider
 networks today.  Typically, the Autonomous System Border Router
 (ASBR) and associated physical links that connect the domains carry a
 multitude of services.  As such, it is important to provide PE node
 and link redundancy, to ensure high service availability and meet the
 end customer service level agreements (SLAs).
 Several current deployments of inter-AS VPLS are implemented like
 inter-AS option A as described in [RFC4364], Section 10, where the
 Virtual Local Area Network (VLAN) is used to hand-off the services
 between two domains.  In these deployments, PE node/link redundancy
 is achieved using Multi-Chassis Link Aggregation (MC-LAG) and ICCP
 [RFC7275].  This, however, places two restrictions on the
 interconnection: the two domains must be interconnected using
 Ethernet links, and the links must be homogeneous, i.e., of the same
 speed, in order to be aggregated.  These two conditions cannot always

Liu, et al. Standards Track [Page 3] RFC 7309 Redundancy for VPLS Inter-domain July 2014

 be guaranteed in live deployments.  For instance, there are many
 scenarios where the interconnection between the domains uses packet
 over Synchronous Optical Networking (SONET) / Synchronous Digital
 Hierarchy (SDH), thereby ruling out the applicability of MC-LAG as a
 redundancy mechanism.  As such, from a technical point of view, it is
 desirable to use PWs to interconnect the VPLS domains, and to offer
 resiliency using PW redundancy mechanisms.
 Multiprotocol Border Gateway Protocol (MP-BGP) can be used for VPLS
 inter-domain protection, as described in [RFC6074], using either
 option B or option C inter-AS models.  However, with this solution,
 the protection time relies on BGP control-plane convergence.  In
 certain deployments, with tight SLA requirements on availability,
 this mechanism may not provide the desired failover time
 characteristics.  Furthermore, in certain situations MP-BGP is not
 deployed for VPLS.  The redundancy solution described in this
 document reuses ICCP [RFC7275] and PW redundancy [RFC6718] to provide
 fast convergence.
 Furthermore, in the case where label switched multicast is not used
 for VPLS multicast [RFC7117], the solution described here provides a
 better behavior compared to inter-AS option B: with option B, each PE
 must perform ingress replication to all other PEs in its local as
 well as the remote domain.  Whereas, with the ICCP solution, the PE
 only replicates to local PEs and to the ASBR.  The ASBR then sends
 traffic point to point to the remote ASBR, and the remote ASBR
 replicates to its local PEs.  As a result, the load of replication is
 distributed and is more efficient than option B.
 Two PW redundancy modes defined in [RFC6718], namely independent mode
 and master/slave mode, are applicable in this solution.  In order to
 maintain control-plane separation between two domains, the
 independent mode is preferred by operators.  The master/slave mode
 provides some enhanced capabilities and, hence, is included in this
 document.

4. Network Use Case

 There are two network use cases for VPLS inter-domain redundancy:
 two-PWs redundancy case, and four-PWs redundancy case.
 Figure 1 presents an example use case with two inter-domain PWs.
 PE3/PE4/PE5/PE6 may be ASBRs of their respective AS, or VPLS PEs
 within its own AS.  PE3 and PE4 belong to one redundancy group (RG),
 and PE5 and PE6 belong to another RG.  A deployment example of this
 use case is where there are only two physical links between two
 domains and PE3 is physically connected with PE5, and PE4 is
 physically connected with PE6.

Liu, et al. Standards Track [Page 4] RFC 7309 Redundancy for VPLS Inter-domain July 2014

               +---------+                 +---------+
       +---+   | +-----+ |   active PW1    |  +-----+|    +---+
       |PE1|---|-| PE3 |-|-----------------|--| PE5 ||----|PE7|
       +---+\  |/+-----+ |                 |  +-----+\   /+---+
        |    \ /  | *    |                 |    * |  |\ /   |
        |     \|  | |ICCP|                 |ICCP| |  | \    |
        |    / \  | *    |                 |    * |  |/ \   |
       +---+/  |\+-----+ |                 |  +-----+/   \+---+
       |PE2|---|-| PE4 |-|-----------------|--| PE6 ||----|PE8|
       +---+   | +-----+ |   standby PW2   |  +-----+|    +---+
               |         |                 |         |
               |         |                 |         |
               |  RG1    |                 |  RG2    |
               +---------+                 +---------+
               operator A network             operator B network
                               Figure 1
 Figure 2 presents a four-PWs inter-domain VPLS redundancy use case.
 PE3/PE4/PE5/PE6 may be ASBRs of their respective AS, or VPLS PEs
 within its own AS.  A deployment example of this use case is where
 there are four physical links between two domains and four PEs are
 physically connected with each other with four links.
               +---------+                 +---------+
       +---+   | +-----+ |                 |  +-----+|    +---+
       |PE1|---|-| PE3 |-|--------PW1------|--| PE5 ||----|PE7|
       |   |   | |     |-|-PW3\     /------|--|     ||    |   |
       +---+\  |/+-----+ |     \   /       |  +-----+\   /+---+
        |    \ /  | *    |      \ /        |    * |  |\ /   |
        |     \|  | |ICCP|       X         |ICCP| |  | \    |
        |    / \  | *    |      / \        |    * |  |/ \   |
       +---+/  |\+-----+ |     /   \       |  +-----+/   \+---+
       |   |   | |     |-|-PW4/     \------|--|     ||    |   |
       |PE2|---|-| PE4 |-|----PW2----------|--| PE6 ||----|PE8|
       +---+   | +-----+ |                 |  +-----+|    +---+
               |         |                 |         |
               |         |                 |         |
               |  RG1    |                 |  RG2    |
               +---------+                 +---------+
             operator A network         operator B network
                               Figure 2

Liu, et al. Standards Track [Page 5] RFC 7309 Redundancy for VPLS Inter-domain July 2014

5. PW Redundancy Application Procedure for Inter-domain Redundancy

 PW redundancy application procedures are described in Section 9.1 of
 [RFC7275].  When a PE node encounters a failure, the other PE takes
 over.  This document reuses the PW redundancy mechanism defined in
 [RFC7275], with new ICCP switchover conditions as specified in
 following section.
 There are two PW redundancy modes defined in [RFC6870]: Independent
 mode and Master/Slave mode.  For the inter-domain four-PW scenario,
 it is required that PEs ensure that the same mode be supported on the
 two ICCP peers in the same RG.  This can be achieved using manual
 configuration at the ICCP peers.  Other methods for ensuring
 consistency are out of the scope of this document.

5.1. ICCP Switchover Condition

5.1.1. Inter-domain PW Failure

 When a PE receives advertisements from the active PE, in the same RG,
 indicating that all the inter-domain PW status has changed to DOWN/
 STANDBY, then if it has the highest priority (after the advertising
 PE), it SHOULD advertise active state for all of its associated
 inter-domain PWs.

5.1.2. PE Node Isolation

 When a PE detects failure of all PWs to the local domain, it SHOULD
 advertise standby state for all its inter-domain PWs to trigger
 remote PE to switchover.

5.1.3. PE Node Failure

 When a PE node detects that the active PE, that is a member of the
 same RG, has gone down, if the local PE has redundant PWs for the
 affected services and has the highest priority (after the failed PE),
 it SHOULD advertise the active state for all associated inter-domain
 PWs.

5.2. Inter-domain Redundancy with Two PWs

 In this use case, it is recommended that the operation be as follows:
 o  ICCP deployment option: ICCP is deployed on VPLS edge nodes in
    both domains;
 o  PW redundancy mode: independent mode only;

Liu, et al. Standards Track [Page 6] RFC 7309 Redundancy for VPLS Inter-domain July 2014

 o  Protection architectures: 1:1 (1 standby, 1 active).
 The switchover rules described in Section 5.1 apply.  Before
 deploying this inter-domain VPLS, the operators should negotiate to
 configure the same PW high/low priority at two PW endpoints.  The
 inter-domain VPLS relationship normally involves a contractual
 process between operators, and the configuration of PW roles forms
 part of this process.  For example, in Figure 1, PE3 and PE5 must
 both have higher/lower priority than PE4 and PE6; otherwise, both PW1
 and PW2 will be in standby state.

5.3. Inter-domain Redundancy with Four PWs

 In this use case, there are two options to provide protection: 1:1
 and 3:1 protection.  The inter-domain PWs that connect to the same PE
 should have proper PW priority to advertise the same active/standby
 state.  For example, in Figure 2, both PW1 and PW3 are connected to
 PE3 and should advertise active/standby state.
 For the 1:1 protection model, the operation would be as follows:
 o  ICCP deployment option: ICCP is deployed on VPLS edge nodes in
    both domains;
 o  PW redundancy mode: independent mode only;
 o  Protection architectures: 1:1 (1 standby, 1 active).
 The switchover rules described in Section 5.1 apply.  In this case,
 the operators do not need to do any coordination of the inter-domain
 PW priority.  The PE detecting one PW DOWN SHOULD set the other PW to
 STANDBY if available, and then synchronize the updated state to its
 ICCP peer.  When a PE detects that the PWs from the ICCP peer PE are
 DOWN or STANDBY, it SHOULD switchover as described in Section 5.1.1.
 There are two variants of the 3:1 protection model.  We will refer to
 them as options A and B.  The implementation MUST support option A
 and MAY support option B.  Option B will be useful when the two
 legacy PEs in one domain do not support the function in this
 document.  The two legacy PEs still need to support PW redundancy
 defined in [RFC6870] and be configured as slave node.
 For option A of the 3:1 protection model, the support of the Request
 Switchover status bit [RFC6870] is required.  The operation is as
 follows:
 o  ICCP deployment option: ICCP is deployed on VPLS edge nodes in
    both domains;

Liu, et al. Standards Track [Page 7] RFC 7309 Redundancy for VPLS Inter-domain July 2014

 o  PW redundancy mode: Independent mode with 'request switchover' bit
    support;
 o  Protection architectures: 3:1 (3 standby, 1 active).
 In this case, the procedure on the PE for the PW failure is per
 Section 6.3 of [RFC6870] and with the following additions:
 o  When the PE detects failure of the active inter-domain PW, it
    SHOULD switch to the other local standby inter-domain PW if
    available, and send an updated LDP PW status message with the
    'request switchover' bit set on that local standby inter-domain PW
    to the remote PE;
 o  Local and remote PE SHOULD also update the new PW status to their
    ICCP peers, respectively, in Application Data Messages with the
    PW-RED Synchronization Request TLV for corresponding service, so
    as to synchronize the latest PW status on both PE sides.
 o  While waiting for the acknowledgement, the PE that sends the
    'request switchover' bit may receive a switchover request from its
    ICCP peer's PW remote endpoint by virtue of the ICCP
    synchronization.  The PE MUST compare IP addresses with that PW
    remote peer.  The PE with a higher IP address SHOULD ignore the
    request and continue to wait for the acknowledgement from its peer
    in the remote domain.  The PE with the lower IP address SHOULD
    clear the 'request switchover' bit and set the 'Preferential
    Forwarding' local status bit, and update the PW status to ICCP
    peer.
 o  The remote PE receiving the 'request switchover' bit SHOULD
    acknowledge the request and activate the PW only when it is ready
    to take over as described in Section 5.1; otherwise, it SHOULD
    ignore the request.
 The PE node isolation failure and PE node failure is described in
 Section 5.1.
 For option B of the 3:1 protection model, master/slave mode support
 is required and should be as follows:
 o  ICCP deployment option: ICCP is deployed on VPLS edge nodes in
    only one domain;
 o  PW redundancy mode: master/slave only;
 o  Protection architectures: 3:1 (3 standby, 1 active).

Liu, et al. Standards Track [Page 8] RFC 7309 Redundancy for VPLS Inter-domain July 2014

 When master/slave PW redundancy mode is employed, the network
 operators of two domains must agree on which domain PEs will be
 master, and configure the devices accordingly.  The inter-domain PWs
 that connect to one PE should have higher PW priority than the PWs on
 the other PE in the same RG.  The procedure on the PE for PW failure
 is as follows:
 o  The PE with higher PW priority should only enable one PW active,
    and the other PWs should be in the standby state.
 o  When the PE detects an active PW DOWN, it SHOULD enable the other
    local standby PW to be active with preference.  Only when two
    inter-domain PWs connected to the PE are DOWN, the ICCP peer PE in
    the same RG SHOULD switchover as described in Section 5.1.
 The PE node isolation failure and PE node failure are described in
 Section 5.1.

6. Management Considerations

 When deploying the inter-domain redundancy mechanism described in
 this document, consistent provisioning is required for proper
 operation.  The two domains must both use the same use case
 (Section 5.2 or Section 5.3).  Within each section, all of the
 described modes and options must be provisioned identically both
 within each RG and between the RGs.  Additionally, for the two-PWs
 redundancy options defined in Section 5.2, the two operators must
 also negotiate to configure same high/low PW priority at the two PW
 endpoints.  If the provisioning is inconsistent, then the inter-
 domain redundancy mechanism may not work properly.

7. Security Considerations

 Besides the security properties of [RFC7275] for the ICCP control
 plane, and [RFC4762] and [RFC6870] for the PW control plane, this
 document has additional security considerations for the ICCP control
 plane.
 In this document, ICCP is deployed between two PEs or ASBRs.  The two
 PEs or ASBRs should only be connected by a network that is well
 managed and whose service levels and availability are highly
 monitored.  This should be ensured by the operator.
 The state flapping on the inter-domain and intra-domain PW may cause
 security threats or be exploited to create denial-of-service attacks.
 For example, excessive PW state flapping (e.g., by malicious peer

Liu, et al. Standards Track [Page 9] RFC 7309 Redundancy for VPLS Inter-domain July 2014

 PE's implementation) may lead to excessive ICCP exchanges.
 Implementations SHOULD provide mechanisms to perform control-plane
 policing and mitigate such types of attacks.

8. Acknowledgements

 The authors would like to thank Sami Boutros, Giles Heron, Adrian
 Farrel, Andrew G.  Malis, and Stephen Kent for their valuable
 comments.

9. Contributors

 Daniel Cohn
 Email:daniel.cohn.ietf@gmail.com
 Yubao Wang
 ZTE Corporation
 Nanjing, China
 Email: wang.yubao@zte.com.cn

10. References

10.1. Normative references

 [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
            Requirement Levels", BCP 14, RFC 2119, March 1997.
 [RFC6870]  Muley, P. and M. Aissaoui, "Pseudowire Preferential
            Forwarding Status Bit", RFC 6870, February 2013.
 [RFC7275]  Martini, L., Salam, S., Sajassi, A., Bocci, M.,
            Matsushima, S., and T. Nadeau, "Inter-Chassis
            Communication Protocol for Layer 2 Virtual Private Network
            (L2VPN) Provider Edge (PE) Redundancy", RFC 7275, June
            2014.

10.2. Informative references

 [RFC4364]  Rosen, E. and Y. Rekhter, "BGP/MPLS IP Virtual Private
            Networks (VPNs)", RFC 4364, February 2006.
 [RFC4762]  Lasserre, M. and V. Kompella, "Virtual Private LAN Service
            (VPLS) Using Label Distribution Protocol (LDP) Signaling",
            RFC 4762, January 2007.

Liu, et al. Standards Track [Page 10] RFC 7309 Redundancy for VPLS Inter-domain July 2014

 [RFC6074]  Rosen, E., Davie, B., Radoaca, V., and W. Luo,
            "Provisioning, Auto-Discovery, and Signaling in Layer 2
            Virtual Private Networks (L2VPNs)", RFC 6074, January
            2011.
 [RFC6718]  Muley, P., Aissaoui, M., and M. Bocci, "Pseudowire
            Redundancy", RFC 6718, August 2012.
 [RFC7117]  Aggarwal, R., Kamite, Y., Fang, L., Rekhter, Y., and C.
            Kodeboniya, "Multicast in Virtual Private LAN Service
            (VPLS)", RFC 7117, February 2014.

Liu, et al. Standards Track [Page 11] RFC 7309 Redundancy for VPLS Inter-domain July 2014

Authors' Addresses

 Zhihua Liu
 China Telecom
 109 Zhongshan Ave.
 Guangzhou 510630
 P.R.China
 EMail: zhliu@gsta.com
 Lizhong Jin
 Shanghai
 P.R.China
 EMail: lizho.jin@gmail.com
 Ran Chen
 ZTE Corporation
 NO.19 East Huayuan Road
 Haidian District Beijing 100191
 P.R.China
 EMail: chen.ran@zte.com.cn
 Dennis Cai
 Cisco
 3750 Cisco Way,
 San Jose, California 95134
 USA
 EMail: dcai@cisco.com
 Samer Salam
 Cisco
 595 Burrard Street, Suite:2123
 Vancouver, BC V7X 1J1
 Canada
 EMail: ssalam@cisco.com

Liu, et al. Standards Track [Page 12]