Network Working Group D. Raftus Request for Comments: 4546 ATI Technologies, Inc. Obsoletes: 2670 E. Cardona Category: Standards Track CableLabs

                                                             June 2006
    Radio Frequency (RF) Interface Management Information Base
 for Data over Cable Service Interface Specifications (DOCSIS) 2.0
                      Compliant RF Interfaces

Status of This Memo

 This document specifies an Internet standards track protocol for the
 Internet community, and requests discussion and suggestions for
 improvements.  Please refer to the current edition of the "Internet
 Official Protocol Standards" (STD 1) for the standardization state
 and status of this protocol.  Distribution of this memo is unlimited.
 This document revises and obsoletes RFC 2670.  Please see Section 5.3
 for a description of the changes from RFC 2670.

Copyright Notice

 Copyright (C) The Internet Society (2006).

Abstract

 This memo defines a portion of the Management Information Base (MIB)
 for use with network management protocols in the Internet community.
 In particular, it defines a set of managed objects for Simple Network
 Management Protocol (SNMP) based management of the Radio Frequency
 (RF) interfaces for systems compliant with the Data Over Cable
 Service Interface Specifications (DOCSIS).

Table of Contents

 1. The Internet-Standard Management Framework ......................2
 2. Glossary ........................................................3
    2.1. Baseline Privacy ...........................................3
    2.2. CATV .......................................................3
    2.3. Channel ....................................................3
    2.4. CM or Cable Modem ..........................................3
    2.5. CMTS or Cable Modem Termination System .....................3
    2.6. Codeword ...................................................4
    2.7. Data Packet ................................................4
    2.8. dBmV .......................................................4
    2.9. DOCSIS .....................................................4

Raftus & Cardona Standards Track [Page 1] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

         2.9.1. DOCSIS 1.0 ..........................................4
         2.9.2. DOCSIS 1.1 ..........................................4
         2.9.3. DOCSIS 2.0 ..........................................4
    2.10. Downstream ................................................5
    2.11. Euro-DOCSIS ...............................................5
    2.12. Head-end ..................................................5
    2.13. MAC Packet ................................................5
    2.14. MCNS ......................................................5
    2.15. Mini-slot .................................................5
    2.16. QPSK (Quadrature Phase Shift Keying) ......................5
    2.17. QAM (Quadrature Amplitude Modulation) .....................5
    2.18. RF ........................................................5
    2.19. Symbol-times ..............................................5
    2.20. Upstream ..................................................6
 3. Overview ........................................................6
    3.1. Textual Conventions ........................................6
         3.1.1. Textual Conventions in RFC 2670 .....................6
         3.1.2. Textual Conventions in RFC 4546 .....................6
    3.2. Structure of the MIB .......................................6
         3.2.1. docsIfBaseObjects ...................................7
         3.2.2. docsIfCmObjects .....................................7
         3.2.3. docsIfCmtsObjects ...................................8
         3.2.4. Relationship to the Interfaces MIB Module ...........8
         3.2.5. Offline Upstream Parameters Handling ...............22
 4. Definitions ....................................................24
 5. Revision History ..............................................134
    5.1. Scope ....................................................134
    5.2. Extension ................................................134
 6. Security Considerations .......................................134
 7. Management Interoperability of DOCSIS 1.0, 1.1, and 2.0 .......136
 8. References ....................................................136
    8.1. Normative References .....................................136
    8.2. Informative References ...................................137

1. The Internet-Standard Management Framework

 For a detailed overview of the documents that describe the current
 Internet-Standard Management Framework, please refer to section 7 of
 RFC 3410 [RFC3410].
 Managed objects are accessed via a virtual information store, termed
 the Management Information Base or MIB.  MIB objects are generally
 accessed through the Simple Network Management Protocol (SNMP).
 Objects in the MIB are defined using the mechanisms defined in the
 Structure of Management Information (SMI).  This memo specifies a MIB
 module that is compliant to the SMIv2, which is described in STD 58,
 RFC 2578 [RFC2578], STD 58, RFC 2579 [RFC2579] STD 58, RFC 2580
 [RFC2580].

Raftus & Cardona Standards Track [Page 2] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

2. Glossary

 The terms in this document are derived either from normal cable
 system usage, or from the documents associated with the Data Over
 Cable Service Interface Specification process.

2.1. Baseline Privacy

 Security interface specification, designed for DOCSIS-compliant cable
 data systems, that ensures device authentication data confidentiality
 in the CATV plant.  See [BPI] and [BPIPLUS].

2.2. CATV

 Originally "Community Antenna Television", it now refers to any cable
 or hybrid fiber and cable system used to deliver video signals to a
 community.

2.3. Channel

 A specific frequency allocation with an RF medium, specified by
 channel width in Hertz (cycles per second) and by center frequency.
 Within the US Cable Systems, upstream channels are generally
 allocated from the 5-42MHz range while downstream channels are
 generally allocated from the 50-750MHz range, depending on the
 capabilities of the given system.  The typical broadcast channel
 width in the US is 6MHz.  Upstream channel widths for DOCSIS vary.
 For European cable systems, upstream channels vary by country.  The
 upper edge of upstream channel allocations varies between 25 MHz to
 65 MHz, and the lower edge of downstream channel allocations varies
 between 47 MHz and 87.5 MHz.  The typical broadcast channel width in
 Europe is 8MHz.  The actual parameters are of concern to systems
 deploying Euro-DOCSIS technology.
 The downstream channels conform to the requirements of ITU-T
 Recommendation J.83 [ITU-T_J.83]

2.4. CM or Cable Modem

 A CM acts as a "slave" station in a DOCSIS-compliant cable data
 system.

2.5. CMTS or Cable Modem Termination System

 A generic term covering a cable bridge or cable router in a head-end.
 A CMTS acts as the master station in a DOCSIS-compliant cable data
 system.  It is the only station that transmits downstream, and it

Raftus & Cardona Standards Track [Page 3] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 controls the scheduling of upstream transmissions by its associated
 CMs.

2.6. Codeword

 A characteristic of the Forward Error Correction scheme, used above
 the RF media layer.
 See "Data-Over-Cable Service Interface Specifications: Radio
 Frequency Interface Specification SP-RFIv2.0-I10-051209".

2.7. Data Packet

 The payload portion of the MAC Packet.

2.8. dBmV

 A measure of RF signal voltage amplitude, whose power level is
 determined by the characteristic impedance.  A zero dB signal power
 is equivalent to 48.75 dBmV signal amplitude in a 75 Ohm system.

2.9. DOCSIS

 "Data Over Cable Service Interface Specification".  A term referring
 to the ITU-T J112 [ITU-T_J.112] Annex B standard for cable modem
 systems.

2.9.1. DOCSIS 1.0

 Cable modem systems that are CM/CMTS compliant to requirements in
 [RFI1.0].  A common reference to DOCSIS 1.0 in this document is the
 upstream channel queuing mechanism, known as Class of Service (COS).

2.9.2. DOCSIS 1.1

 Cable modem systems that are CM/CMTS compliant to requirements in
 [ITU-T_J.112].  DOCSIS 1.1 references in this document are in part
 associated with the upstream and downstream Quality of Service (QOS).
 The term DOCSIS 1.x is used in this document to refer to both DOCSIS
 1.0 and DOCSIS 1.1.

2.9.3. DOCSIS 2.0

 Cable modem systems that are CM/CMTS compliant to requirements in
 [ITU-T_J.122].  DOCSIS 2.0 corresponds to the second generation of
 radio-frequency interface specifications of DOCSIS.

Raftus & Cardona Standards Track [Page 4] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

2.10. Downstream

 The direction from the head-end towards the subscriber.

2.11. Euro-DOCSIS

 Cable modem systems CM/CMTS that conform to the European spectrum
 lineup and are compliant to requirements of Annex F in [ITU-T_J.122].

2.12. Head-end

 The origination point in most cable systems of the subscriber video
 signals.  Generally also the location of the CMTS equipment.

2.13. MAC Packet

 A DOCSIS PDU.

2.14. MCNS

 "Multimedia Cable Network System".  Generally replaced in usage by
 DOCSIS.

2.15. Mini-slot

 In general, an interval of time that is allocated by the CMTS to a
 given CM for that CM to transmit in an upstream direction.  See
 [ITU-T_J.122]

2.16. QPSK (Quadrature Phase Shift Keying)

 A particular modulation scheme on an RF medium.  See [Proakis00].

2.17. QAM (Quadrature Amplitude Modulation)

 A particular modulation scheme on RF medium.  Usually expressed with
 a number indicating the size of the modulation constellation (e.g.,
 16 QAM).  See [Proakis00].

2.18. RF

 Radio Frequency.

2.19. Symbol-times

 A characteristic of the RF modulation scheme.  See [ITU-T_J.122].

Raftus & Cardona Standards Track [Page 5] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

2.20. Upstream

 The direction from the subscriber towards the head-end.

3. Overview

 This MIB module provides a set of objects required for the management
 of DOCSIS-compliant Cable Modem (CM) and Cable Modem Termination
 System (CMTS) RF interfaces.  The specification is derived in part
 from the parameters and protocols described in [ITU-T_J.122].
 In this document, the key words "MUST", "MUST NOT", "REQUIRED",
 "SHALL", "SHALL NOT", "SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY",
 and "OPTIONAL" are to be interpreted as described in [RFC2119].

3.1. Textual Conventions

 This MIB module defines new textual conventions for CM and CMTS
 indications of DOCSIS 2.0 RFI capabilities, configuration, usage, and
 backward compatible modes of operation, as defined in [RFI2.0].  With
 the same purpose, there are some textual conventions that represent
 capabilities and modes of operation of [RFI1.1] that are not covered
 by RFC 2670, and are managed proprietarily in the DOCSIS OSSI 1.1
 specification [OSSI1.1].

3.1.1. Textual Conventions in RFC 2670

 RFC 2670 defined two textual conventions, TenthdBmV and TenthdB,
 which are power measurement representations.

3.1.2. Textual Conventions in RFC 4546

 This MIB module defines the textual convention DocsisUpstreamType to
 represent the DOCSIS 1.0 [RFI1.0] and DOCSIS 2.0 [RFI2.0] upstream
 burst modulation profiles types.
 This MIB module defines the textual conventions DocsisVersion and
 DocsisQosVersion to represent the DOCSIS 1.0 [RFI1.0] and DOCSIS 1.1
 [RFI1.1] COS/QOS capabilities and modes of operation.

3.2. Structure of the MIB

 This MIB module is structured as three groups:
 o  Management information pertinent to both Cable Modem (CM) and
    Cable Modem Termination System (CMTS) (docsIfBaseObjects).

Raftus & Cardona Standards Track [Page 6] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 o  Management information pertinent to Cable Modem only
    (docsIfCmObjects).
 o  Management information pertinent to Cable Modem Termination System
    only (docsIfCmtsObjects).
 Tables within each of these groups cover different functions; e.g.,
 upstream queue services, channel characteristics, MAC layer
 management, etc.  Rows created automatically (e.g., by the device
 according to the hardware configuration) may and generally will have
 a mixture of configuration and status objects within them.  Rows that
 are meant to be created by the management station are generally
 restricted to configuration (read-create) objects.

3.2.1. docsIfBaseObjects

 docsIfDownstreamChannelTable - This table describes the existing
 downstream channels for a CMTS and the received downstream channel
 for a CM.
 docsIfUpstreamChannelTable - This table describes the existing
 upstream channels for a CMTS and the current upstream transmission
 channel for a CM.
 docsIfQosProfileTable - This table describes the valid Quality of
 Service profiles for the cable data system.
 docsIfSignalQualityTable - This table is used to monitor RF signal
 quality characteristics of received signals.
 docsIfDocsisBaseCapability - This object is used to indicate the
 highest level of DOCSIS version a cable device can support.

3.2.2. docsIfCmObjects

 docsIfCmMacTable - This table is used to monitor the DOCSIS MAC
 interface and can be considered an extension to the ifEntry.
 docsIfCmStatusTable - This table maintains a number of status objects
 and counters for cable modems.  There is a comparable table at the
 CMTS, docsIfCmtsCmStatusTable, which maintains similar counters from
 the CMTS point of view.
 docsIfCmServiceTable - This table describes the upstream service
 queues available at this CM.  There is a comparable table at the
 CMTS, docsIfCmtsServiceEntry, which describes the service queues from
 the point of view of the CMTS.

Raftus & Cardona Standards Track [Page 7] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

3.2.3. docsIfCmtsObjects

 docsIfCmtsMacTable - Describes the attributes of each CMTS MAC
 interface.
 docsIfCmtsStatusTable - This table provides a set of aggregated
 counters that roll-up values and events that occur on the underlying
 sub-interfaces.
 docsIfCmtsCmStatusTable - This table is used to hold information
 about known (i.e., ranging, registered, and/or previously online)
 cable modems on the system serviced by this CMTS.
 docsIfCmtsServiceTable - This table provides access to the
 information related to upstream service queues.
 docsIfCmtsModulationTable - This table allows control over the
 modulation profiles for RF channels associated with this CMTS.
 docsIfCmtsMacToCmTable - This table allows fast access into the
 docsIfCmtsCmTable via a MAC address (of the CM) interface.
 docsIfCmtsChannelUtilizationTable - This table provides statistical
 load usage data for attached upstream and downstream physical
 channels.
 docsIfCmtsDownChannelCounterTable - This table provides statistical
 data for attached downstream channels, appropriate as input for load
 usage calculations.
 docsIfCmtsUpChannelCounterTable - This table provides statistical
 data for attached upstream channels, appropriate as input for load
 usage calculations.

3.2.4. Relationship to the Interfaces MIB Module

 This section clarifies the relationship of this MIB module to the
 Interfaces MIB [RFC2863].  Several areas of correlation are addressed
 in the following subsections.  The implementer is referred to the
 Interfaces MIB document in order to understand the general intent of
 these areas.

3.2.4.1. Layering Model

 An instance of ifEntry exists for each RF downstream interface, for
 each RF upstream interface, for each upstream logical Channel, and
 for each RF MAC layer.

Raftus & Cardona Standards Track [Page 8] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 The ifStackTable [RFC2863] MUST be implemented to identify the
 relationships among sub-interfaces.
 The following example illustrates a CMTS MAC interface with one
 downstream and two upstream interfaces.
                               | <== to network layer
         +------------------ --+-------------------------------+
         |                     RF MAC                          |
         +--+------------------+------------------------+------+
            |                  |                        |
    +-------+-----+     +------+------+          +------+------+
    | Downstream1 |     |  Upstream1  |          |  Upstream2  |
    |             |     |             |          |             |
    +-------------+     ++-----------++          ++-----------++
                         |           |            |           |
                    +----+----+ +----+----+  +----+----+ +----+----+
                    |  Ch-1   | |  Ch-2   |  |  Ch-1   | |  Ch-2   |
                    |(A/TDMA) | |(S-CDMA) |  |(A/TDMA) | |(S-CDMA) |
                    +---------+ +---------+  +---------+ +---------+
                               Figure 1
 As can be seen from this example, the RF MAC interface is layered on
 top of the downstream and upstream interfaces, and the RF upstream
 interface is layered on top of an upstream logical channel.
 In this example, the assignment of index values could be as follows:
    ifIndex       ifType                     Description
       2    docsCableMaclayer(127)           CATV MAC Layer
       3    docsCableDownstream(128)         CATV Downstream interface
       4    docsCableUpstream(129)           CATV Upstream interface
       5    docsCableUpstream(129)           CATV Upstream interface
       6    docsCableUpstreamChannel(205)    CATV Upstream Channel
       7    docsCableUpstreamChannel(205)    CATV Upstream Channel
       8    docsCableUpstreamChannel(205)    CATV Upstream Channel
       9    docsCableUpstreamChannel(205)    CATV Upstream Channel
                               Figure 2

Raftus & Cardona Standards Track [Page 9] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 The corresponding ifStack entries would then be:
            | IfStackHigherLayer | ifStackLowerLayer |
            |         0          |         2         |
            |         2          |         3         |
            |         2          |         4         |
            |         2          |         5         |
            |         4          |         6         |
            |         4          |         7         |
            |         5          |         8         |
            |         5          |         9         |
            |         3          |         0         |
            |         6          |         0         |
            |         7          |         0         |
            |         8          |         0         |
            |         9          |         0         |
                               Figure 3
 The same interface model can also be used in Telephony or Telco
 Return systems.  A pure Telco Return system (Cable Modem, as well as
 Cable Modem Termination System) would not have upstream cable
 channels, only downstream cable channels.  Systems supporting both
 Telco Return and cable upstream channels can use the above model
 without modification.
 Telco Return upstream channel(s) management is outside the scope of
 this document.

3.2.4.2. Virtual Circuits

 This medium does not support virtual circuits, and this area is not
 applicable to this MIB module.

3.2.4.3. ifTestTable

 The ifTestTable is optional for DOCSIS CM/CMTS implementations, but
 is not specifically influenced by the RF MIB.

3.2.4.4. ifRcvAddressTable

 The ifRcvAddressTable is optional for DOCSIS CM/CMTS implementations,
 but is not specifically influenced by the RF MIB.

Raftus & Cardona Standards Track [Page 10] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

3.2.4.5. ifEntry

 This section documents only the differences from the requirements
 specified in the Interfaces MIB module.  See that MIB module for
 columns omitted from the descriptions below.

3.2.4.5.1. ifEntry for Downstream Interfaces

 The ifEntry for downstream interfaces supports the
 ifGeneralInformationGroup and the ifPacketGroup of the Interfaces MIB
 module.  This is an output-only interface at the CMTS, and all input
 status counters -- ifIn* -- will return zero.  This is an input-only
 interface at the CM, and all output status counters -- ifOut* -- will
 return zero.

3.2.4.5.1.1. ifEntry for Downstream Interfaces in Cable Modem

            Termination System
 ifTable           Comments
 ==============    ===========================================
 ifIndex           Each CATV Downstream interface is represented
                   by an ifEntry.
 ifType            The IANA value of docsCableDownstream(128).
 ifSpeed           Return the speed of this downstream channel.
                   The returned value is the raw bandwidth in bits/s
                   of this interface.  This is the symbol rate
                   multiplied with the number of bits per symbol.
 ifHighSpeed       Return the speed of this downstream channel.
                   The returned value is the raw bandwidth in
                   megabits/s of this interface.  This is the symbol
                   rate multiplied with the number of bits per
                   symbol.
 ifPhysAddress     Return the zero-length OCTET STRING.
 ifAdminStatus     The administrative status of this interface.
 ifOperStatus      The current operational status of this interface.
 ifMtu             The size of the largest frame that can be
                   sent on this interface, specified in octets.
                   The value includes the length of the MAC header.
 ifInOctets
 ifHCInOctets      Return zero.

Raftus & Cardona Standards Track [Page 11] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 ifInUcastPkts
 ifHCInUcastPkts   Return zero.
 ifInMulticastPkts
 ifHCInMulticastPkts
                   Return zero.
 ifInBroadcastPkts
 ifHCInBroadcastPkts
                   Return zero.
 ifInDiscards      Return zero.
 ifInErrors        Return zero.
 ifInUnknownProtos Return zero.
 ifOutOctets
 ifHCOutOctets     The total number of octets transmitted on this
                   interface.  This includes MAC packets as well as
                   data packets, and includes the length of the MAC
                   header.
 ifOutUcastPkts
 ifHCOutUcastPkts  The number of unicast packets transmitted on this
                   interface.  This includes MAC packets as well as
                   data packets.
 ifOutMulticastPkts
 ifHCOutMulticastPkts
                   Return the number of multicast packets
                   transmitted on this interface.
                   This includes MAC packets as well as data
                   packets.
 ifOutBroadcastPkts
 ifHCOutBroadcastPkts
                   Return the number of broadcast packets transmitted
                   on this interface.  This includes MAC packets as
                   well as data packets.
 ifOutDiscards     The total number of outbound packets which
                   were discarded.  Possible reasons are:
                   buffer shortage.
 ifOutErrors       The number of packets that could not be
                   transmitted due to errors.
 ifPromiscuousMode Return false.

Raftus & Cardona Standards Track [Page 12] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

3.2.4.5.1.2. ifEntry for Downstream Interfaces in Cable Modem

 ifTable           Comments
 ==============    ===========================================
 ifIndex           Each CATV Downstream interface is represented
                   by an ifEntry.
 ifType            The IANA value of docsCableDownstream(128).
 ifSpeed           Return the speed of this downstream channel.
                   The returned value the raw bandwidth in bits/s
                   of this interface.  This is the symbol rate
                   multiplied with the number of bits per symbol.
 ifHighSpeed       Return the speed of this downstream channel.
                   The returned value the raw bandwidth in megabits/s
                   of this interface.  This is the symbol rate
                   multiplied with the number of bits per symbol.
 ifPhysAddress     Return the zero-length OCTET STRING.
 ifAdminStatus     The administrative status of this interface.
 ifOperStatus      The current operational status of this interface.
 ifMtu             The size of the largest frame that can be
                   received from this interface, specified in octets.
                   The value includes the length of the MAC header.
 ifInOctets
 ifHCInOctets      The total number of octets received on this
                   interface.  This includes data packets as well as
                   MAC packets, and includes the length of the
                   MAC header.
 ifInUcastPkts
 ifHCInUcastPkts   The number of unicast packets received on this
                   interface.  This includes data packets as well as
                   MAC packets.
 ifInMulticastPkts
 ifHCInMulticastPkts
                   Return the number of multicast packets received
                   on this interface.  This includes data packets as
                   well as MAC packets.

Raftus & Cardona Standards Track [Page 13] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 ifInBroadcastPkts
 ifHCInBroadcastPkts
                   Return the number of broadcast packets received
                   on this interface.  This includes data packets
                   as well as MAC packets.
 ifInDiscards      The total number of received packets that have
                   been discarded.
                   The possible reasons are: buffer shortage.
 ifInErrors        The number of inbound packets that contained
                   errors preventing them from being deliverable
                   to higher layers.
                   Possible reasons are: MAC FCS error.
 ifInUnknownProtos The number of frames with an unknown packet type.
                   These are MAC frames with an unknown packet type.
 ifOutOctets       Return zero.
 ifHCOutOctets
 ifOutUcastPkts    Return zero.
 ifHCOutUcastPkts
 ifOutMulticastPkts
 ifHCOutMulticastPkts
                   Return zero.
 ifOutBroadcastPkts
 ifHCOutBroadcastPkts
                   Return zero.
 ifOutDiscards     Return zero.
 ifOutErrors       Return zero.
 ifPromiscuousMode Refer to the Interfaces MIB.

3.2.4.5.2. ifEntry for Upstream Interfaces

 Each supported interface of the type docsCableUpstream(129) must have
 a corresponding ifEntry.  The ifEntry for upstream interfaces
 supports the ifGeneralInformationGroup and the ifPacketGroup of the
 Interfaces MIB.  This is an input-only interface at the CMTS, and all
 output status counters -- ifOut* -- will return zero.  This is an
 output only interface at the CM, and all input status counters --
 ifIn* -- will return zero.

Raftus & Cardona Standards Track [Page 14] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

3.2.4.5.2.1. ifEntry for Upstream Interfaces in Cable Modem Termination

            System
 ifTable           Comments
 ==============    ===========================================
 ifIndex           Each RF Cable Upstream interface is represented
                   by an ifEntry.
 ifType            The IANA value of docsCableUpstream (129).
 ifSpeed           Return the maximum channel throughput (not payload
                   throughput) supported by the interface.
                   The maximum throughput is calculated for the case
                   where upstream channels are configured to maximize
                   interface throughput.
 ifHighSpeed       Return the maximum channel throughput (not payload
                   throughput) supported by the interface.
                   The maximum throughput is calculated for the case
                   where upstream channels are configured to maximize
                   interface throughput.  Units for this object are
                   (1/1 000 000) * IfSpeed.
 ifPhysAddress     Return the zero-length OCTET STRING.
 ifAdminStatus     The administrative status of this interface.
 ifOperStatus      The current operational status of this interface.
                   This reflects the total status of all the channels
                   under this interface.  So if at least one channel
                   has a physical connection this interface has
                   connection.
 ifMtu             The size of the largest frame that can be
                   transmitted on this interface, specified in
                   octets.  The value includes the length of the MAC
                   header.  This is the maximum of all the ifMtu of
                   all the channels under this interface.
 ifInOctets
 ifHCInOctets      The total (sum) number of octets received on all
                   the upstream channels under this
                   interface.  This includes data packets as well as
                   MAC packets, and includes the length of the
                   MAC header.

Raftus & Cardona Standards Track [Page 15] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 ifInUcastPkts
 ifHCInUcastPkts   The total number of unicast packets received on
                   all the upstream channels under this
                   interface.  This includes data packets as well as
                   MAC packets.
 ifInMulticastPkts
 ifHCInMulticastPkts
                   Return the total number of multicast packets
                   received on all the upstream channels under this
                   interface.  This includes data packets as well as
                   MAC layer packets.
 ifInBroadcastPkts
 ifHCInBroadcastPkts
                   Return the total number of broadcast packets
                   received on all the upstream channels under this
                   interface.  This includes data packets as well as
                   MAC packets.
 ifInDiscards      The total number of received packets that have
                   been discarded on all the upstream channels under
                   this interface.
                   The possible reasons are: buffer shortage.
 ifInErrors        The total number of inbound packets that contained
                   errors preventing them from being deliverable
                   to higher layers.
                   Possible reasons are: MAC FCS error.
 ifInUnknownProtos The total number of frames with an unknown packet
                   type.  These are MAC frames with an unknown packet
                   type.
 ifOutOctets       Return zero.
 ifHCOutOctets
 ifOutUcastPkts    Return zero.
 ifHCOutOctets
 ifOutMulticastPkts
 ifHCOutMulticastPkts
                   Return zero.
 ifOutBroadcastPkts
 ifHCOutBroadcastPkts
                   Return zero.

Raftus & Cardona Standards Track [Page 16] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 ifOutDiscards     Return zero.
 ifOutErrors       Return zero.

3.2.4.5.2.2. ifEntry for Upstream Interfaces in Cable Modem

 ifTable           Comments
 ==============    ===========================================
 ifIndex           Each RF Cable Upstream interface is represented
                   by an ifEntry.
 ifType            The IANA value of docsCableUpstream (129).
 ifSpeed           Return the speed of this upstream interface.
                   The returned value is the raw bandwidth
                   in bits/s of this interface.
 ifHighSpeed       Return the speed of this upstream interface.
                   The returned value is the raw bandwidth
                   in megabits/s of this interface.
 ifPhysAddress     Return the zero-length OCTET STRING.
 ifAdminStatus     The administrative status of this interface.
 ifOperStatus      The current operational status of this interface.
 ifMtu             The size of the largest frame that can be
                   transmitted on this interface, specified in
                   octets.  The value includes the length of the MAC
                   header.
 ifInOctets        Return zero.
 ifHCInOctets
 ifInUcastPkts     Return zero.
 ifHCInUcastPkts
 ifInMulticastPkts
 ifHCInMulticastPkts
                   Return zero.
 ifInBroadcastPkts
 ifHCInBroadcastPkts
                   Return zero.
 ifInDiscards      Return zero.

Raftus & Cardona Standards Track [Page 17] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 ifInErrors        Return zero.
 ifInUnknownProtos Return zero.
 ifOutOctets
 ifHCOutOctets     The total number of octets transmitted on this
                   interface.  This includes MAC packets as well as
                   data packets, and includes the length of the MAC
                   header.
 ifOutUcastPkts
 ifHCOutUcastPkts  The number of unicast packets transmitted on this
                   interface.  This includes MAC packets as well as
                   data packets.
 ifOutMulticastPkts
 ifHCOutMulticastPkts
                   Return the number of multicast packets transmitted
                   on this interface.
                   This includes MAC packets as well as data packets.
 ifOutBroadcastPkts
 ifHCOutBroadcastPkts
                   Return the number of broadcast packets transmitted
                   on this interface.
                   This includes MAC packets as well as data packets.
 ifOutDiscards     The total number of outbound packets that
                   were discarded.  Possible reasons are:
                   buffer shortage.
 ifOutErrors       The number of packets that could not be
                   transmitted due to errors.
 ifPromiscuousMode Return false.

3.2.4.5.3. ifEntry for Upstream Channels

 Each supported channel of the type docsCableUpstreamChannel(205) must
 have a corresponding ifEntry.
 The ifEntry for upstream channels supports the
 ifGeneralInformationGroup and the ifPacketGroup of the Interfaces
 MIB.  This is an input only interface at the CMTS and all output
 status counters -- ifOut* -- will return zero.  DOCSIS CMs are not
 required to support logical upstream channels.

Raftus & Cardona Standards Track [Page 18] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

3.2.4.5.3.1. ifEntry for Upstream Channels in Cable Modem Termination

            System
 ifTable           Comments
 ==============    ===========================================
 ifIndex           Each RF Cable Upstream channel is represented
                   by an ifEntry.
 ifType            The IANA value of docsCableUpstreamChannel (205).
 ifSpeed           Return the speed of this upstream channel.
                   The returned value is the raw bandwidth
                   in bits/s of this channel.
 ifHighSpeed       Return the speed of this upstream channel.
                   The returned value is the raw bandwidth
                   in megabits/s of this channel.
 ifPhysAddress     Return the zero-length OCTET STRING.
 ifAdminStatus     The administrative status of this interface.
 ifOperStatus      The current operational status of this interface.
 ifMtu             The size of the largest frame that can be
                   received on this interface, specified in octets.
                   The value includes the length of the MAC header.
 ifInOctets        The total number of octets received on this
                   interface.  This includes data packets as well as
                   MAC packets, and includes the length of the
                   MAC header.
 ifInUcastPkts
 ifHCInUcastPkts
                   The number of unicast packets received on this
                   interface.  This includes data packets as well as
                   MAC packets.
 ifInMulticastPkts
 ifHCInMulticastPkts
                   Return the number of multicast packets received
                   on this interface.  This includes data packets as
                   well as MAC layer packets.

Raftus & Cardona Standards Track [Page 19] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 ifInBroadcastPkts
 ifHCInBroadcastPkts
                   Return the number of broadcast packets received
                   on this interface.  This includes data packets
                   as well as MAC packets.
 ifInDiscards      The total number of received packets that have
                   been discarded.
                   The possible reasons are: buffer shortage.
 ifInErrors        The number of inbound packets that contained
                   errors preventing them from being deliverable
                   to higher layers.
                   Possible reasons are: MAC FCS error.
 ifInUnknownProtos The number of frames with an unknown packet type.
                   These are MAC frames with an unknown packet type.
 ifOutOctets       Return zero.
 ifHCOutOctets
 ifOutUcastPkts    Return zero.
 ifHCOutUcastPkts
 ifOutMulticastPkts
 ifHCOutMulticastPkts
                   Return zero.
 ifOutBroadcastPkts
 ifHCOutBroadcastPkts
                   Return zero.
 ifOutDiscards     Return zero.
 ifOutErrors       Return zero.

3.2.4.5.4. ifEntry for the MAC Layer

 The ifEntry for the MAC Layer supports the ifGeneralInformationGroup
 and the ifPacketGroup of the Interfaces MIB.  This interface provides
 an aggregate view of status for the lower level downstream and
 upstream interfaces.
 ifTable           Comments
 ==============    ===========================================
 ifIndex           Each RF Cable MAC layer entity is represented
                   by an ifEntry.

Raftus & Cardona Standards Track [Page 20] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 ifType            The IANA value of docsCableMaclayer(127).
 ifSpeed           Return zero.
 ifPhysAddress     Return the physical address of this interface.
 ifAdminStatus     The administrative status of this interface.
 ifOperStatus      The current operational status of the MAC
                   layer interface.
 ifHighSpeed       Return zero.
 ifMtu             Return 1500.
 ifInOctets
 ifHCInOctets      The total number of data octets received on this
                   interface, targeted for upper protocol layers.
 ifInUcastPkts
 ifHCInUcastPkts   The number of unicast packets received on this
                   interface, targeted for upper protocol layers.
 ifInMulticastPkts
 ifHCInMulticastPkts
                   Return the number of multicast packets received
                   on this interface, targeted for upper protocol
                   layers.
 ifInBroadcastPkts
 ifHCInBroadcastPkts
                   Return the number of broadcast packets received
                   on this interface, targeted for upper protocol
                   layers.
 ifInDiscards      The total number of received packets that have
                   been discarded.
                   The possible reasons are: buffer shortage.
 ifInErrors        The number of inbound packets that contained
                   errors preventing them from being deliverable
                   to higher layers.
                   Possible reasons are: data packet FCS error,
                   invalid MAC header.
 ifInUnknownProtos The number of frames with an unknown packet type.
                   This is the number of data packets targeted for
                   upper protocol layers with an unknown packet type.

Raftus & Cardona Standards Track [Page 21] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 ifOutOctets       The total number of octets, received from upper
 ifHCOutOctets     protocol layers and transmitted on this interface.
 ifOutUcastPkts
 ifHCOutUcastPkts  The number of unicast packets, received from upper
                   protocol layers and transmitted on this interface.
 ifOutMulticastPkts
 ifHCOutMulticastPkts
                   Return the number of multicast packets received
                   from upper protocol layers and transmitted on this
                   interface.
 ifOutBroadcastPkts
 ifHCOutBroadcastPkts
                   Return the number of broadcast packets received
                   from upper protocol layers and transmitted on this
                   interface.
 ifOutDiscards     The total number of outbound packets that
                   were discarded.  Possible reasons are:
                   buffer shortage.
 ifOutErrors       The number of packets that could not be
                   transmitted due to errors.
 ifPromiscuousMode Refer to the Interfaces MIB.

3.2.5. Offline Upstream Parameters Handling

3.2.5.1. Overview

 This section describes the offline configuration of the DOCSIS 2.0
 upstream logical interface parameters.  The purpose of this feature
 is to guarantee that upstream logical interface parameters (such as
 modulation profile, channel type, mini-slot size, and SCDMA
 attributes) are consistent prior to committing changes to an active
 upstream logical interface.  This mechanism can reduce possible
 downtime of the upstream interface by minimizing SNMP SET operations
 to in-service upstream interfaces.  This mechanism is supported by
 CMTSs and is not applicable to CMs.

3.2.5.2. Operation

 This mechanism uses three upstream channel MIB objects defined for
 DOCSIS 2.0 CMTS implementations:

Raftus & Cardona Standards Track [Page 22] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 docsIfUpChannelStatus - The RowStatus object for the creation of
 temporary interfaces in the upstream interface table.  A temporary
 entry is used to modify, validate, and commit upstream parameters of
 a physical interface.  In the CMTS, a physical upstream interface
 refers to an upstream logical channel interface.
 docsIfUpChannelCloneFrom - This MIB object associates a physical
 interface with a temporary interface for the purpose of updating the
 upstream parameters of the physical interface.
 docsIfUpChannelUpdate - This MIB object is the commit object that
 transfers the validated upstream parameters from the temporary
 interface to the physical interface.
 The offline upstream parameters handling operation is as follows:
 o  A temporary interface is created in which docsIfUpChannelStatus is
    set to 'createAndWait', which turns the new create entry status to
    'notReady'.
 o  A SET to docsIfUpChannelCloneFrom in the temporary interface to
    the physical interface ifIndex value performs two actions:
  • Creates the association of the physical interface to the

temporary interface.

  • Copies the original upstream parameters from the physical

interface to the temporary interface, which turns its status to

       'notInService'.
 o  The operator modifies the temporary interface parameters to the
    desired values.
 o  At this point, a SET to 'active' to the RowStatus of the temporary
    interface is successful if all parameters in the temporary
    interface are valid for the associated physical interface;
    otherwise, the temporary entry remains with status 'notInservice',
    and the SET returns the error 'commitFailed'.
 o  When the temporary interface status is 'active', a SET to
    docsIfUpChannelUpdate to 'true' transfers the temporary interface
    parameters values to the physical interface.
 o  After completion of the update operations, the temporary interface
    is destroyed, setting the docsIfUpChannelStatus to 'destroy'.

Raftus & Cardona Standards Track [Page 23] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

3.2.5.3. Relation of docsIfUpChannelStatus and ifMib

 The main purpose of docsIfUpChannelStatus is the creation of
 temporary interfaces for offline handling of the configuration of
 physical interfaces; it does not manage the creation or control of
 physical interfaces.  To maintain a consistent operation and status
 report of interfaces, this object does not manage the administrative
 and operational status of physical interfaces.

4. Definitions

 DOCS-IF-MIB DEFINITIONS ::= BEGIN
   IMPORTS
      MODULE-IDENTITY,
      OBJECT-TYPE,
      Unsigned32,
      Integer32,
      Counter32,
      Counter64,
      TimeTicks,
      IpAddress,
      transmission
              FROM SNMPv2-SMI        -- [RFC2578]
      TEXTUAL-CONVENTION,
      MacAddress,
      RowStatus,
      TruthValue,
      TimeInterval,
      TimeStamp,
      StorageType
              FROM SNMPv2-TC         -- [RFC2579]
      OBJECT-GROUP,
      MODULE-COMPLIANCE
              FROM SNMPv2-CONF       -- [RFC2580]
      ifIndex, InterfaceIndexOrZero
              FROM IF-MIB            -- [RFC2863]
      InetAddressType,
      InetAddress
              FROM INET-ADDRESS-MIB  -- [RFC4001]
      IANAifType
              FROM IANAifType-MIB;   -- [IANA]
 docsIfMib MODULE-IDENTITY
      LAST-UPDATED    "200605240000Z" -- May 24, 2006
      ORGANIZATION    "IETF IPCDN Working Group"
      CONTACT-INFO

Raftus & Cardona Standards Track [Page 24] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          "        David Raftus
           Postal: ATI Technologies Inc.
                   340 Terry Fox Drive, Suite 202
                   Ottawa Ontario
                   Canada
           Phone:  +1 613 592 1052 ext.222
           E-mail: david.raftus@ati.com
                   Eduardo Cardona
           Postal: Cable Television Laboratories, Inc.
                   858 Coal Creek Circle
                   Louisville, CO 80027-9750
                   U.S.A.
           Phone:  Tel:    +1 303 661 9100
                   Fax:    +1 303 661 9199
           E-mail: e.cardona@cablelabs.com;mibs@cablelabs.com
           IETF IPCDN Working Group
           General Discussion: ipcdn@ietf.org
           Subscribe: http://www.ietf.org/mailman/listinfo/ipcdn
           Archive: ftp://ftp.ietf.org/ietf-mail-archive/ipcdn
           Co-chairs: Richard Woundy, Richard_Woundy@cable.comcast.com
                      Jean-Francois Mule, jf.mule@cablelabs.com"
      DESCRIPTION
          "This is the MIB Module for DOCSIS 2.0-compliant Radio
           Frequency (RF) interfaces in Cable Modems and
           Cable Modem Termination Systems.
           Copyright (C) The Internet Society (2006).  This
           version of this MIB module is part of RFC 4546; see
           the RFC itself for full legal notices."
      REVISION        "200605240000Z"
      DESCRIPTION
          "Revision of the IETF RF MIB module for DOCSIS 2.0.
           This version published as RFC 4546.
           This MIB module revision includes the following
           among others:
           Usage of ifType (205) for upstream logical channels.
           Addition of downstream and upstream utilization
           counters.
           Additional statistics per upstream interface.
           Upstream channel offline configuration mechanism.
           Added MIB support for new DOCSIS 2.0 modulation
           attributes.
           Euro-DOCSIS downstream interleave values.
           Adjustments to RFC 2670 definitions based on
           the MIB review guidelines from the IETF

Raftus & Cardona Standards Track [Page 25] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Operations and Management Area (OPS)."
      REVISION "199908190000Z"
      DESCRIPTION
          "Initial version, published as RFC 2670.
           Modified by Mike St. Johns to fix problems identified by
           the first pass of the MIB doctor.  Of special note,
           docsIfRangingResp and docsIfCmtsInsertionInterval were
           obsoleted and replaced by other objects with the same
           functionality, but with more appropriate syntax."
      ::= { transmission 127 }
  1. - Textual Conventions
 TenthdBmV ::= TEXTUAL-CONVENTION
      DISPLAY-HINT "d-1"
      STATUS       current
      DESCRIPTION
          "This data type represents power levels that are normally
           expressed in dBmV.  Units are in tenths of a dBmV;
           for example, 5.1 dBmV will be represented as 51."
      SYNTAX       Integer32
 TenthdB ::= TEXTUAL-CONVENTION
      DISPLAY-HINT "d-1"
      STATUS       current
      DESCRIPTION
          "This data type represents power levels that are normally
           expressed in dB.  Units are in tenths of a dB;
           for example, 5.1 dB will be represented as 51."
      SYNTAX       Integer32
 DocsisVersion ::= TEXTUAL-CONVENTION
     STATUS          current
     DESCRIPTION
         "Indicates the DOCSIS Radio Frequency specification being
          referenced.
          'docsis10' indicates DOCSIS 1.0.
          'docsis11' indicates DOCSIS 1.1.
          'docsis20' indicates DOCSIS 2.0."
     SYNTAX        INTEGER {
          docsis10 (1),
          docsis11 (2),
          docsis20 (3)
     }
 DocsisQosVersion ::= TEXTUAL-CONVENTION

Raftus & Cardona Standards Track [Page 26] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

     STATUS          current
     DESCRIPTION
         "Indicates the referenced quality-of-service
          level.
          'docsis10 refers to DOCSIS 1.0 Class of
          Service queuing services, and 'docsis11' refers
          to DOCSIS 1.1 Quality of Service."
     SYNTAX        INTEGER {
         docsis10 (1),
         docsis11 (2)
     }
 DocsisUpstreamType ::= TEXTUAL-CONVENTION
     STATUS          current
     DESCRIPTION
          "Indicates the DOCSIS Upstream Channel Type.
           'unknown' means information not available.
           'tdma' is related to TDMA, Time Division
           Multiple Access; 'atdma' is related to A-TDMA,
           Advanced Time Division Multiple Access,
           'scdma' is related to S-CDMA, Synchronous
           Code Division Multiple Access.
           'tdmaAndAtdma is related to simultaneous support of
           TDMA and A-TDMA modes."
     SYNTAX          INTEGER {
         unknown(0),
         tdma(1),
         atdma(2),
         scdma(3),
         tdmaAndAtdma(4)
     }
  DocsEqualizerData ::= TEXTUAL-CONVENTION
       STATUS       current
       DESCRIPTION
           "This data type represents the equalizer data
            as measured at the receiver interface.
            The format of the equalizer follows the structure of the
            Transmit Equalization Adjust RNG-RSP TLV of DOCSIS RFI
            v2.0 :
            1 byte Main tap location 1..(n + m)
            1 byte Number of forward taps per symbol
            1 byte Number of forward taps: n
            1 byte Number of reverse taps: m
            Following are the equalizer coefficients:
            First, forward taps coefficients:
            2 bytes F1 (real),  2 bytes  F1 (imag)

Raftus & Cardona Standards Track [Page 27] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

            ...
            2 bytes Fn (real),  2 bytes  Fn (imag)
            Then, reverse taps coefficients:
            2 bytes D1 (real),  2 bytes  D1 (imag)
            ...
            2 bytes Dm (real),  2 bytes  Dm (imag)
            The equalizer coefficients are considered signed 16-bit
            integers in the range from -32768 (0x8000) to 32767
            (0x7FFF).
            DOCSIS specifications require up to a maximum of
            64 equalizer taps (n + m); therefore, this object size
             can get up 260 bytes (4 + 4x64).
            The minimum object size (other than zero) for a t-spaced
            tap with a minimum of 8 symbols will be 36 (4 + 4x8)."
       REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Figure 8-23."
       SYNTAX       OCTET STRING(SIZE (0 | 36..260))
 docsIfMibObjects  OBJECT IDENTIFIER ::= { docsIfMib 1 }
 docsIfBaseObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 1 }
 docsIfCmObjects   OBJECT IDENTIFIER ::= { docsIfMibObjects 2 }
 docsIfCmtsObjects OBJECT IDENTIFIER ::= { docsIfMibObjects 3 }
  1. -
  2. - BASE GROUP
  3. -
  1. -
  2. - The following table is implemented on both the Cable Modem
  3. - and the Cable Modem Termination System. This table is
  4. - read only for the CM.
  5. -
 docsIfDownstreamChannelTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfDownstreamChannelEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table describes the attributes of downstream
           channels (frequency bands)."
      REFERENCE

Raftus & Cardona Standards Track [Page 28] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-16, and 6-17."
      ::= { docsIfBaseObjects 1 }
 docsIfDownstreamChannelEntry OBJECT-TYPE
      SYNTAX      DocsIfDownstreamChannelEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "An entry provides a list of attributes for a single
           downstream channel.
           An entry in this table exists for each ifEntry with an
           ifType of docsCableDownstream(128)."
      INDEX { ifIndex }
      ::= { docsIfDownstreamChannelTable 1 }
 DocsIfDownstreamChannelEntry ::= SEQUENCE {
          docsIfDownChannelId               Integer32,
          docsIfDownChannelFrequency        Integer32,
          docsIfDownChannelWidth            Integer32,
          docsIfDownChannelModulation       INTEGER,
          docsIfDownChannelInterleave       INTEGER,
          docsIfDownChannelPower            TenthdBmV,
          docsIfDownChannelAnnex            INTEGER,
          docsIfDownChannelStorageType      StorageType
      }
 docsIfDownChannelId OBJECT-TYPE
      SYNTAX      Integer32 (0..255)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The Cable Modem Termination System identification of the
           downstream channel within this particular MAC interface.
           if the interface is down, the object returns the most
           current value.  If the downstream channel ID is unknown,
           this object returns a value of 0."
      ::= { docsIfDownstreamChannelEntry 1 }
 docsIfDownChannelFrequency OBJECT-TYPE
      SYNTAX      Integer32 (0..1000000000)
      UNITS       "hertz"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "The center of the downstream frequency associated with
           this channel.  This object will return the current tuner

Raftus & Cardona Standards Track [Page 29] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           frequency.  If a CMTS provides IF output, this object
           will return 0, unless this CMTS is in control of the
           final downstream frequency.  See the associated
           compliance object for a description of valid frequencies
           that may be written to this object."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.3.3."
      ::= { docsIfDownstreamChannelEntry 2 }
 docsIfDownChannelWidth OBJECT-TYPE
      SYNTAX      Integer32 (0..16000000)
      UNITS       "hertz"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "The bandwidth of this downstream channel.  Most
           implementations are expected to support a channel width
           of 6 MHz (North America) and/or 8 MHz (Europe).  See the
           associated compliance object for a description of the
           valid channel widths for this object."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 6-17."
      ::= { docsIfDownstreamChannelEntry 3 }
 docsIfDownChannelModulation OBJECT-TYPE
      SYNTAX      INTEGER {
          unknown(1),
          other(2),
          qam64(3),
          qam256(4)
      }
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "The modulation type associated with this downstream
           channel.  If the interface is down, this object either
           returns the configured value (CMTS), the most current
           value (CM), or the value of unknown(1).  See the
           associated conformance object for write conditions and
           limitations.  See the reference for specifics on the
           modulation profiles implied by qam64 and qam256."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio

Raftus & Cardona Standards Track [Page 30] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 6-17."
      ::= { docsIfDownstreamChannelEntry 4 }
 docsIfDownChannelInterleave OBJECT-TYPE
      SYNTAX      INTEGER {
          unknown(1),
          other(2),
          taps8Increment16(3),
          taps16Increment8(4),
          taps32Increment4(5),
          taps64Increment2(6),
          taps128Increment1(7),
          taps12increment17(8)
      }
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "The Forward Error Correction (FEC) interleaving used
           for this downstream channel.
           Values are defined as follows:
           taps8Increment16(3):   protection 5.9/4.1 usec,
                                  latency .22/.15 msec
           taps16Increment8(4):   protection 12/8.2 usec,
                                  latency .48/.33 msec
           taps32Increment4(5):   protection 24/16 usec,
                                  latency .98/.68 msec
           taps64Increment2(6):   protection 47/33 usec,
                                  latency 2/1.4 msec
           taps128Increment1(7):  protection 95/66 usec,
                                  latency 4/2.8 msec
           taps12increment17(8):  protection 18/14 usec,
                                  latency 0.43/0.32 msec
          The value 'taps12increment17' is supported by EuroDOCSIS
          cable systems only, and the others by DOCSIS cable systems.
           If the interface is down, this object either returns
           the configured value (CMTS), the most current value (CM),
           or the value of unknown(1).
           The value of other(2) is returned if the interleave
           is known but not defined in the above list.
           See the associated conformance object for write
           conditions and limitations.  See the reference for the FEC
           configuration described by the setting of this object."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,

Raftus & Cardona Standards Track [Page 31] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Table 6-15."
      ::= { docsIfDownstreamChannelEntry 5 }
 docsIfDownChannelPower OBJECT-TYPE
      SYNTAX      TenthdBmV
      UNITS       "dBmV"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "At the CMTS, the operational transmit power.  At the CM,
           the received power level.
           If the interface is down, this object either returns
           the configured value (CMTS), the most current value (CM)
           or the value of 0.  See the associated conformance object
           for write conditions and limitations.  See the reference
           for recommended and required power levels."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-16, 6-17."
      ::= { docsIfDownstreamChannelEntry 6 }
 docsIfDownChannelAnnex OBJECT-TYPE
      SYNTAX      INTEGER {
          unknown(1),
          other(2),
          annexA(3),
          annexB(4),
          annexC(5)
      }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value of this object indicates the conformance of
           the implementation to important regional cable standards.
           annexA : Annex A from ITU-T J.83 is used.
                    (equivalent to EN 300 429)
           annexB : Annex B from ITU-T J.83 is used.
           annexC : Annex C from ITU-T J.83 is used."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Sections 6.3.1, and H.3.1."
      ::= { docsIfDownstreamChannelEntry 7 }
 docsIfDownChannelStorageType OBJECT-TYPE
      SYNTAX       StorageType
      MAX-ACCESS   read-only

Raftus & Cardona Standards Track [Page 32] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      STATUS       current
      DESCRIPTION
          "The storage type for this conceptual row.
           Entries with this object set to permanent(4)
           do not require write operations for read-write
           objects."
      ::= { docsIfDownstreamChannelEntry 8 }
  1. -
  2. - The following table is implemented on both the CM and the CMTS.
  3. - For the CM, only attached channels appear in the table. For the
  4. - CM, this table is read-only as well.
  5. -
 docsIfUpstreamChannelTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfUpstreamChannelEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table describes the attributes of attached upstream
           channels."
      ::= { docsIfBaseObjects 2 }
 docsIfUpstreamChannelEntry OBJECT-TYPE
      SYNTAX      DocsIfUpstreamChannelEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "List of attributes for a single upstream channel.  For
           DOCSIS 2.0 CMTSs, an entry in this table exists for
           each ifEntry with an ifType of docsCableUpstreamChannel
           (205).
           For DOCSIS 1.x CM/CMTSs and DOCSIS 2.0 CMs, an entry in
           this table exists for each ifEntry with an ifType of
           docsCableUpstream (129).
           For DOCSIS 2.0 CMTSs, two classes of interfaces can be
           defined for this table:
            o Upstream Physical Interfaces: The traditional DOCSIS
              1.x CMTS upstream interface ifType 129 and the DOCSIS
              2.0 ifType 205 that are functional.  In other words,
              interfaces that represent upstream receivers within
              an RF MAC interface.
              Entries of physical interfaces are exposed to the
              management interface with their corresponding
              ifStack hierarchy and are not administratively
              created by this table.

Raftus & Cardona Standards Track [Page 33] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

            o Upstream Temporary Interfaces: A fictitious
              interface created for the purpose of manipulating
              physical interface parameters offline, then
              validating prior to updating the target physical
              interface.
           In case of a reinitialization of the managed system,
           physical interfaces values persist while the temporary
           interfaces are not recreated.
           This mechanism helps to minimize service disruptions
           originating in situations where a group of interface
           parameter values need to be consistent with each other
           in SET operations.  A temporary buffer
           (temporary interface) is provided to allow the CMTS
           to validate the parameters offline."
      INDEX { ifIndex }
      ::= { docsIfUpstreamChannelTable 1 }
 DocsIfUpstreamChannelEntry ::= SEQUENCE {
          docsIfUpChannelId                     Integer32,
          docsIfUpChannelFrequency              Integer32,
          docsIfUpChannelWidth                  Integer32,
          docsIfUpChannelModulationProfile      Unsigned32,
          docsIfUpChannelSlotSize               Unsigned32,
          docsIfUpChannelTxTimingOffset         Unsigned32,
          docsIfUpChannelRangingBackoffStart    Integer32,
          docsIfUpChannelRangingBackoffEnd      Integer32,
          docsIfUpChannelTxBackoffStart         Integer32,
          docsIfUpChannelTxBackoffEnd           Integer32,
          docsIfUpChannelScdmaActiveCodes       Unsigned32,
          docsIfUpChannelScdmaCodesPerSlot      Integer32,
          docsIfUpChannelScdmaFrameSize         Unsigned32,
          docsIfUpChannelScdmaHoppingSeed       Unsigned32,
          docsIfUpChannelType                   DocsisUpstreamType,
          docsIfUpChannelCloneFrom              InterfaceIndexOrZero,
          docsIfUpChannelUpdate                 TruthValue,
          docsIfUpChannelStatus                 RowStatus,
          docsIfUpChannelPreEqEnable            TruthValue
      }
 docsIfUpChannelId OBJECT-TYPE
      SYNTAX      Integer32 (0..255)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The CMTS identification of the upstream channel."
      ::= { docsIfUpstreamChannelEntry 1 }

Raftus & Cardona Standards Track [Page 34] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 docsIfUpChannelFrequency OBJECT-TYPE
      SYNTAX      Integer32 (0..1000000000)
      UNITS       "hertz"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The center of the frequency band associated with this
           upstream interface.  This object returns 0 if the frequency
           is undefined or unknown.  Minimum permitted upstream
           frequency is 5,000,000 Hz for current technology.  See
           the associated conformance object for write conditions
           and limitations."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 4-2."
      ::= { docsIfUpstreamChannelEntry 2 }
 docsIfUpChannelWidth OBJECT-TYPE
      SYNTAX      Integer32 (0..64000000)
      UNITS       "hertz"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The bandwidth of this upstream interface.  This object
           returns 0 if the interface width is undefined or unknown.
           Minimum permitted interface width is currently 200,000 Hz.
           See the associated conformance object for write conditions
           and limitations."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 6-5."
      ::= { docsIfUpstreamChannelEntry 3 }
 docsIfUpChannelModulationProfile OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "An entry identical to the docsIfModIndex in the
           docsIfCmtsModulationTable that describes this channel.
           This channel is further instantiated there by a grouping
           of interval usage codes (IUCs) that, together, fully
           describe the channel modulation.  This object returns 0 if
           the docsIfCmtsModulationTable entry does not exist or is
           empty.  See the associated conformance object for write
           conditions and limitations.

Raftus & Cardona Standards Track [Page 35] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Setting this object returns an 'inconsistentValue'
           error if the following conditions are not satisfied:
           1. All the IUC entries in the selected modulation profile
           MUST have the same value of docsIfCmtsModChannelType.
           2. All of the Modulation parameters in the selected
           modulation profile MUST be consistent with the other
           parameters in this docsIfUpstreamChannelEntry."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 8-19."
      ::= { docsIfUpstreamChannelEntry 4 }
 docsIfUpChannelSlotSize OBJECT-TYPE
      SYNTAX      Unsigned32
      UNITS       "ticks"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Applicable to TDMA and ATDMA channel types only.
           The number of 6.25 microsecond ticks in each upstream
           mini-slot.  Returns zero if the value is undefined or
           unknown or in case of an SCDMA channel.
           See the associated conformance object for write
           conditions and limitations."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.1.2.4."
      ::= { docsIfUpstreamChannelEntry 5 }
 docsIfUpChannelTxTimingOffset OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "At the CM, a measure of the current round trip time
           obtained from the ranging offset (initial ranging offset +
           ranging offset adjustments).
           At the CMTS, the maximum of timing offset, among all the
           CMs that are/were present on the channel, taking into
           account all ( initial + periodic ) timing offset
           corrections that were sent for each of the CMs.  Generally,
           these measurements are positive, but if the measurements
           are negative, the value of this object is zero.  Used for
           timing of CM upstream transmissions to ensure synchronized
           arrivals at the CMTS.
           Units are one 64th fraction of 6.25 microseconds."

Raftus & Cardona Standards Track [Page 36] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.19."
      ::= { docsIfUpstreamChannelEntry 6 }
 docsIfUpChannelRangingBackoffStart OBJECT-TYPE
      SYNTAX      Integer32 (0..16)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The initial random backoff window to use when retrying
           Ranging Requests.  Expressed as a power of 2.  A value of
           16 at the CMTS indicates that a proprietary adaptive retry
           mechanism is to be used.  See the associated conformance
           object for write conditions and limitations."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Sections 8.3.4, and 9.4."
      ::= { docsIfUpstreamChannelEntry 7 }
 docsIfUpChannelRangingBackoffEnd OBJECT-TYPE
      SYNTAX      Integer32 (0..16)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The final random backoff window to use when retrying
           Ranging Requests.  Expressed as a power of 2.  A value of
           16 at the CMTS indicates that a proprietary adaptive retry
           mechanism is to be used.  See the associated conformance
           object for write conditions and limitations."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.4, and 9.4."
      ::= { docsIfUpstreamChannelEntry 8 }
 docsIfUpChannelTxBackoffStart OBJECT-TYPE
      SYNTAX      Integer32 (0..16)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The initial random backoff window to use when retrying
           transmissions.  Expressed as a power of 2.  A value of 16
           at the CMTS indicates that a proprietary adaptive retry
           mechanism is to be used.  See the associated conformance
           object for write conditions and limitations."

Raftus & Cardona Standards Track [Page 37] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.4, and 9.4."
      ::= { docsIfUpstreamChannelEntry 9 }
 docsIfUpChannelTxBackoffEnd OBJECT-TYPE
      SYNTAX      Integer32 (0..16)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The final random backoff window to use when retrying
           transmissions.  Expressed as a power of 2.  A value of 16
           at the CMTS indicates that a proprietary adaptive retry
           mechanism is to be used.  See the associated conformance
           object for write conditions and limitations."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.4, and 9.4."
      ::= { docsIfUpstreamChannelEntry 10 }
 docsIfUpChannelScdmaActiveCodes OBJECT-TYPE
      SYNTAX     Unsigned32 (0|64..66|68..70|72|74..78|80..82|84..88
                              |90..96|98..100|102|104..106|108
                              |110..112|114..126|128)
      MAX-ACCESS read-create
      STATUS     current
      DESCRIPTION
          "Applicable for SCDMA channel types only.
           Number of active codes.  Returns zero for
           Non-SCDMA channel types.  Note that legal
           values from 64..128 MUST be non-prime."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.11.2.1."
      ::= { docsIfUpstreamChannelEntry 11 }
 docsIfUpChannelScdmaCodesPerSlot OBJECT-TYPE
      SYNTAX      Integer32(0 | 2..32)
      UNITS       "codesperMinislots"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Applicable for SCDMA channel types only.
           The number of SCDMA codes per mini-slot.
           Returns zero if the value is undefined or unknown or in

Raftus & Cardona Standards Track [Page 38] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           case of a TDMA or ATDMA channel."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.11.2.1."
      ::= { docsIfUpstreamChannelEntry 12 }
 docsIfUpChannelScdmaFrameSize OBJECT-TYPE
      SYNTAX      Unsigned32 (0..32)
      UNITS       "spreadIntervals"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Applicable for SCDMA channel types only.
           SCDMA Frame size in units of spreading intervals.
           This value returns zero for non-SCDMA Profiles."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.12."
      ::= { docsIfUpstreamChannelEntry 13 }
 docsIfUpChannelScdmaHoppingSeed OBJECT-TYPE
      SYNTAX     Unsigned32 (0..32767)
      MAX-ACCESS read-create
      STATUS     current
      DESCRIPTION
          "Applicable for SCDMA channel types only.
           15-bit seed used for code hopping sequence initialization.
           Returns zero for non-SCDMA channel types.
           Setting this value to a value different than zero for
           non-SCDMA channel types returns the error 'wrongValue'."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.14.1."
      ::= { docsIfUpstreamChannelEntry 14 }
 docsIfUpChannelType OBJECT-TYPE
      SYNTAX      DocsisUpstreamType
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Reflects the Upstream channel type.
           This object returns the value of docsIfCmtsModChannelType
           for the modulation profile selected in
           docsIfUpChannelModulationProfile for this row."
      REFERENCE

Raftus & Cardona Standards Track [Page 39] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.1."
      ::= { docsIfUpstreamChannelEntry 15 }
 docsIfUpChannelCloneFrom OBJECT-TYPE
      SYNTAX      InterfaceIndexOrZero
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "This object contains the ifIndex value of the physical
           interface row entry whose parameters are to be adjusted.
           Upon setting this object to the ifIndex value of a
           physical interface, the following interface objects values
           are copied to this entry:
           docsIfUpChannelFrequency,
           docsIfUpChannelWidth,
           docsIfUpChannelModulationProfile,
           docsIfUpChannelSlotSize,
           docsIfUpChannelRangingBackoffStart,
           docsIfUpChannelRangingBackoffEnd,
           docsIfUpChannelTxBackoffStart,
           docsIfUpChannelTxBackoffEnd,
           docsIfUpChannelScdmaActiveCodes,
           docsIfUpChannelScdmaCodesPerSlot,
           docsIfUpChannelScdmaFrameSize,
           docsIfUpChannelScdmaHoppingSeed,
           docsIfUpChannelType, and
           docsIfUpChannelPreEqEnable
           Setting this object to the value of a non-existent or
           a temporary upstream interface returns the error
           'wrongValue'.
           This object MUST contain a value of zero for physical
           interfaces entries.
           Setting this object in row entries that correspond to
           physical interfaces returns the error 'wrongValue'."
      ::= { docsIfUpstreamChannelEntry 16 }
 docsIfUpChannelUpdate OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Used to perform the copy of adjusted parameters from the
           temporary interface entry to the physical interface
           indicated by the docsIfUpChannelCloneFrom object.  The
           transfer is initiated through an SNMP SET to 'true' of

Raftus & Cardona Standards Track [Page 40] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           this object.
           A SET to 'true' fails and returns error 'commitFailed'
           if docsIfUpChannelStatus value is 'notInService', which
           means that the interface parameters values are not
           compatible with each other or have not been validated yet.
           Reading this object always returns 'false'."
      ::= { docsIfUpstreamChannelEntry 17 }
 docsIfUpChannelStatus OBJECT-TYPE
      SYNTAX      RowStatus
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "This object is only used for the creation of a temporary
           upstream row with the purpose of updating the parameters
           of a physical upstream channel entry.
           The following restrictions apply to this object:
           1. This object is not writable for physical interfaces.
           2. Temporary interface entries are only created by a SET
              of this object to createandWait(5).
           3. ifAdminStatus from the Interface MIB RFC 2863 is used
              to take a physical upstream channel offline, to be
              consistent with DOCSIS 1.x operation, as indicated in
              RFC 2670.
              In addition,
               o ifAdminStatus 'down' is reflected in this object
                 as 'notInService'.
               o ifOperStatus 'down' while ifAdminStatus 'up' is
                 reflected in this object as 'notInservice'.
           4. Temporary created rows MUST be set to 'active' with
              the purpose of validating upstream parameter
              consistency prior to transferring the parameters to the
              physical interface.
           Below is a mandatory procedure for adjusting the values
           of a physical interface:
           1. Create a temporary interface entry through an SNMP SET
              using 'createAndWait'.  At this point, the RowStatus
              reports 'notReady'.
              The Manager entity uses an ifIndex value outside the
              operational range of the physical interfaces for the
              creation of a temporary interface.
           2. Set the docsIfUpChannelCloneFrom object to the ifIndex
              value of the physical row to update.  Now
              docsIfUpChannelStatus reports 'notInService'.
           3. Change the upstream parameters to the desired values
              in the temporary row.

Raftus & Cardona Standards Track [Page 41] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           4. Validate that all parameters are consistent by setting
              docsIfUpChannelStatus to 'active'.  A failure to set the
              RowStatus to 'active' returns the error 'commitFailed',
              which means the parameters are not compatible with the
              target physical interface.
           5. With docsIfUpChannelStatus 'active', transfer the
              parameters to the target physical interface by setting
              the object docsIfUpChannelUpdate to 'true'.
           6. Delete the temporary row by setting
              docsIfUpChannelStatus to 'destroy'."
      ::= { docsIfUpstreamChannelEntry 18 }
 docsIfUpChannelPreEqEnable OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "At the CMTS, this object is used to enable or disable
           pre-equalization on the upstream channel represented by
           this table instance.  At the CM, this object is read-only
           and reflects the status of pre-equalization as represented
           in the RNG-RSP.  Pre-equalization is considered enabled at
           the CM if a RNG-RSP with pre-equalization data has been
           received at least once since the last mac
           reinitialization."
      DEFVAL {false}
      ::= { docsIfUpstreamChannelEntry 19 }
  1. - The following table describes the attributes of each class of
  2. - service. The entries in this table are referenced from the
  3. - docsIfServiceEntries. They exist as a separate table in order to
  4. - reduce redundant information in docsIfServiceTable.
  5. -
  6. - This table is implemented at both the CM and the CMTS.
  7. - The CM need only maintain entries for the classes of service
  8. - referenced by its docsIfCmServiceTable.
  9. -
 docsIfQosProfileTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfQosProfileEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Describes the attributes for each class of service."
      ::= { docsIfBaseObjects 3 }
 docsIfQosProfileEntry OBJECT-TYPE
      SYNTAX      DocsIfQosProfileEntry

Raftus & Cardona Standards Track [Page 42] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Describes the attributes for a single class of service.
           If implemented as read-create in the Cable Modem
           Termination System, creation of entries in this table is
           controlled by the value of
           docsIfCmtsQosProfilePermissions.
           If implemented as read-only, entries are created based
           on information in REG-REQ MAC messages received from
           cable modems (for Cable Modem Termination System), or
           based on information extracted from the TFTP option file
           (for Cable Modem).
           In the Cable Modem Termination System, read-only entries
           are removed if no longer referenced by
           docsIfCmtsServiceTable.
           An entry in this table MUST not be removed while it is
           referenced by an entry in docsIfCmServiceTable (Cable
           Modem) or docsIfCmtsServiceTable (Cable Modem Termination
           System).
           An entry in this table SHOULD NOT be changeable while
           it is referenced by an entry in docsIfCmtsServiceTable.
           If this table is created automatically, there SHOULD only
           be a single entry for each Class of Service.  Multiple
           entries with the same Class of Service parameters are NOT
           RECOMMENDED."
      INDEX { docsIfQosProfIndex }
      ::= { docsIfQosProfileTable 1 }
 DocsIfQosProfileEntry ::= SEQUENCE {
          docsIfQosProfIndex                Integer32,
          docsIfQosProfPriority             Integer32,
          docsIfQosProfMaxUpBandwidth       Integer32,
          docsIfQosProfGuarUpBandwidth      Integer32,
          docsIfQosProfMaxDownBandwidth     Integer32,
          docsIfQosProfMaxTxBurst           Integer32,  -- deprecated
          docsIfQosProfBaselinePrivacy      TruthValue,
          docsIfQosProfStatus               RowStatus,
          docsIfQosProfMaxTransmitBurst     Integer32,
          docsIfQosProfStorageType          StorageType
      }
 docsIfQosProfIndex OBJECT-TYPE
      SYNTAX      Integer32 (1..16383)

Raftus & Cardona Standards Track [Page 43] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "The index value that uniquely identifies an entry
           in the docsIfQosProfileTable."
      ::= { docsIfQosProfileEntry 1 }
 docsIfQosProfPriority OBJECT-TYPE
      SYNTAX      Integer32 (0..7)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "A relative priority assigned to this service when
           allocating bandwidth.  Zero indicates lowest priority
           and seven indicates highest priority.
           Interpretation of priority is device-specific.
           MUST NOT be changed while this row is active."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Annex C.1.1.4."
      DEFVAL { 0 }
      ::= { docsIfQosProfileEntry 2 }
 docsIfQosProfMaxUpBandwidth OBJECT-TYPE
      SYNTAX      Integer32 (0..100000000)
      UNITS "bits per second"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The maximum upstream bandwidth, in bits per second,
           allowed for a service with this service class.
           Zero if there is no restriction of upstream bandwidth.
           MUST NOT be changed while this row is active."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Annex C.1.1.4."
      DEFVAL { 0 }
      ::= { docsIfQosProfileEntry 3 }
 docsIfQosProfGuarUpBandwidth OBJECT-TYPE
      SYNTAX      Integer32 (0..100000000)
      UNITS "bits per second"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Minimum guaranteed upstream bandwidth, in bits per second,

Raftus & Cardona Standards Track [Page 44] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           allowed for a service with this service class.
           MUST NOT be changed while this row is active."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Annex C.1.1.4."
      DEFVAL { 0 }
      ::= { docsIfQosProfileEntry 4 }
 docsIfQosProfMaxDownBandwidth OBJECT-TYPE
      SYNTAX      Integer32 (0..100000000)
      UNITS "bits per second"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The maximum downstream bandwidth, in bits per second,
           allowed for a service with this service class.
           Zero if there is no restriction of downstream bandwidth.
           MUST NOT be changed while this row is active."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Annex C.1.1.4."
      DEFVAL { 0 }
      ::= { docsIfQosProfileEntry 5 }
 docsIfQosProfMaxTxBurst OBJECT-TYPE
      SYNTAX      Integer32 (0..255)
      UNITS "mini-slots"
      MAX-ACCESS  read-create
      STATUS      deprecated
      DESCRIPTION
          "The maximum number of mini-slots that may be requested
           for a single upstream transmission.
           A value of zero means there is no limit.
           MUST NOT be changed while this row is active.
           This object has been deprecated and replaced by
           docsIfQosProfMaxTransmitBurst, to fix a mismatch
           of the units and value range with respect to the DOCSIS
           Maximum Upstream Channel Transmit Burst Configuration
           Setting."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           C.1.1.4."
      DEFVAL { 0 }
      ::= { docsIfQosProfileEntry 6 }

Raftus & Cardona Standards Track [Page 45] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 docsIfQosProfBaselinePrivacy OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Indicates whether Baseline Privacy is enabled for this
           service class.
           MUST NOT be changed while this row is active."
      DEFVAL { false }
      ::= { docsIfQosProfileEntry 7 }
 docsIfQosProfStatus OBJECT-TYPE
      SYNTAX      RowStatus
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "This is object is used to create or delete rows in
           this table.  This object MUST NOT be changed from active
           while the row is referenced by any entry in either
           docsIfCmServiceTable (on the CM) or
           docsIfCmtsServiceTable (on the CMTS)."
      ::= { docsIfQosProfileEntry 8 }
 docsIfQosProfMaxTransmitBurst OBJECT-TYPE
      SYNTAX      Integer32 (0..65535)
      UNITS       "bytes"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The maximum number of bytes that may be requested for a
           single upstream transmission.  A value of zero means there
           is no limit.  Note: This value does not include any
           physical layer overhead.
           MUST NOT be changed while this row is active."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Annex C.1.1.4."
      DEFVAL { 0 }
      ::= { docsIfQosProfileEntry 9 }
 docsIfQosProfStorageType OBJECT-TYPE
      SYNTAX       StorageType
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
          "The storage type for this conceptual row.
           Entries with this object set to permanent(4)

Raftus & Cardona Standards Track [Page 46] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           do not require write operations for writable
           objects."
      ::= { docsIfQosProfileEntry 10 }
 docsIfSignalQualityTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfSignalQualityEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "At the CM, describes the PHY signal quality of downstream
           channels.  At the CMTS, this object describes the PHY
           signal quality of upstream channels.  At the CMTS, this
           table MAY exclude contention intervals."
      ::= { docsIfBaseObjects 4 }
 docsIfSignalQualityEntry OBJECT-TYPE
      SYNTAX      DocsIfSignalQualityEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "At the CM, this object describes the PHY characteristics of
           a downstream channel.  At the CMTS, it describes the PHY
           signal quality of an upstream channel.
           An entry in this table exists for each ifEntry with an
           ifType of docsCableDownstream(128) for Cable Modems.
           For DOCSIS 1.1 Cable Modem Termination Systems, an entry
           exists for each ifEntry with an ifType of
           docsCableUpstream (129).
           For DOCSIS 2.0 Cable Modem Termination Systems, an entry
           exists for each ifEntry with an ifType of
           docsCableUpstreamChannel (205)."
      INDEX { ifIndex }
      ::= { docsIfSignalQualityTable 1 }
 DocsIfSignalQualityEntry ::= SEQUENCE {
          docsIfSigQIncludesContention  TruthValue,
          docsIfSigQUnerroreds          Counter32,
          docsIfSigQCorrecteds          Counter32,
          docsIfSigQUncorrectables      Counter32,
          docsIfSigQSignalNoise         TenthdB,
          docsIfSigQMicroreflections    Integer32,
          docsIfSigQEqualizationData    DocsEqualizerData,
          docsIfSigQExtUnerroreds       Counter64,
          docsIfSigQExtCorrecteds       Counter64,
          docsIfSigQExtUncorrectables   Counter64
      }
 docsIfSigQIncludesContention OBJECT-TYPE

Raftus & Cardona Standards Track [Page 47] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      SYNTAX      TruthValue
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "true(1) if this CMTS includes contention intervals in
           the counters in this table.  Always false(2) for CMs."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.4.1"
      ::= { docsIfSignalQualityEntry 1 }
 docsIfSigQUnerroreds OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received on this channel without error.
           This includes all codewords, whether or not they
           were part of frames destined for this device.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Sections 6.2.4, and 6.3.6."
      ::= { docsIfSignalQualityEntry 2 }
 docsIfSigQCorrecteds OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received on this channel with correctable
           errors.  This includes all codewords, whether or not
           they were part of frames destined for this device.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Sections 6.2.4, and 6.3.6."

Raftus & Cardona Standards Track [Page 48] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      ::= { docsIfSignalQualityEntry 3 }
 docsIfSigQUncorrectables OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received on this channel with uncorrectable
           errors.  This includes all codewords, whether or not
           they were part of frames destined for this device.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Sections 6.2.4, and 6.3.6."
      ::= { docsIfSignalQualityEntry 4 }
 docsIfSigQSignalNoise OBJECT-TYPE
      SYNTAX      TenthdB
      UNITS       "TenthdB"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Signal/Noise ratio as perceived for this channel.
           At the CM, this object  describes the Signal/Noise of the
           downstream channel.  At the CMTS, it describes the
           average Signal/Noise of the upstream channel."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 4-1 and 4-2"
      ::= { docsIfSignalQualityEntry 5 }
 docsIfSigQMicroreflections OBJECT-TYPE
      SYNTAX      Integer32 (0..255)
      UNITS       "-dBc"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Microreflections, including in-channel response
           as perceived on this interface, measured in dBc below
           the signal level.
           This object is not assumed to return an absolutely
           accurate value, but it gives a rough indication

Raftus & Cardona Standards Track [Page 49] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           of microreflections received on this interface.
           It is up to the implementer to provide information
           as accurately as possible."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 4-1 and 4-2"
      ::= { docsIfSignalQualityEntry 6 }
 docsIfSigQEqualizationData OBJECT-TYPE
         SYNTAX      DocsEqualizerData
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
             "At the CM, this object returns the equalization data for
              the downstream channel.
              At the CMTS, this object is not applicable and is not
              instantiated.  Note that previous CMTS implementations
              may instantiate this object in two ways:
              - An equalization value indicating an equalization
                average for the upstream channel.  Those values have
                vendor-dependent interpretations.
              - Return a zero-length OCTET STRING to indicate that
                the value is unknown or if there is no equalization
                data available or defined."
         REFERENCE
             "DOCSIS Radio Frequency Interface Specification,
              Figure 6-23."
         ::= { docsIfSignalQualityEntry 7 }
 docsIfSigQExtUnerroreds OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received on this channel without error.
           This includes all codewords, whether or not they
           were part of frames destined for this device.
           This is the 64-bit version of docsIfSigQUnerroreds.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio

Raftus & Cardona Standards Track [Page 50] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Sections 6.2.4, and 6.3.6."
      ::= { docsIfSignalQualityEntry 8 }
 docsIfSigQExtCorrecteds OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received on this channel with correctable
           errors.  This includes all codewords, whether or not
           they were part of frames destined for this device.
           This is the 64-bit version of docsIfSigQCorrecteds.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Sections 6.2.4, and 6.3.6."
      ::= { docsIfSignalQualityEntry 9 }
 docsIfSigQExtUncorrectables OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received on this channel with uncorrectable
           errors.  This includes all codewords, whether or not
           they were part of frames destined for this device.
           This is the 64-bit version of docsIfSigQUncorrectables.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Sections 6.2.4, 6.3.6."
      ::= { docsIfSignalQualityEntry 10 }
  1. -
  2. - DOCSIS Version of the device
  3. -

Raftus & Cardona Standards Track [Page 51] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 docsIfDocsisBaseCapability OBJECT-TYPE
         SYNTAX      DocsisVersion
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
             "Indication of the DOCSIS capability of the device."
         REFERENCE
             "Data-Over-Cable Service Interface Specifications: Radio
              Frequency Interface Specification SP-RFIv2.0-I10-051209,
              Annex G."
         ::= { docsIfBaseObjects 5 }
  1. -
  2. - CABLE MODEM GROUP
  3. -
  1. -
  2. - The CM MAC Table
  3. -
 docsIfCmMacTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmMacEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Describes the attributes of each CM MAC interface,
           extending the information available from ifEntry."
      ::= { docsIfCmObjects 1 }
 docsIfCmMacEntry OBJECT-TYPE
      SYNTAX      DocsIfCmMacEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "An entry containing objects describing attributes of
           each MAC entry, extending the information in ifEntry.
           An entry in this table exists for each ifEntry with an
           ifType of docsCableMaclayer(127)."
      INDEX { ifIndex }
      ::= { docsIfCmMacTable 1 }
 DocsIfCmMacEntry ::= SEQUENCE {
          docsIfCmCmtsAddress           MacAddress,
          docsIfCmCapabilities          BITS,
          docsIfCmRangingRespTimeout    TimeTicks,
          docsIfCmRangingTimeout        TimeInterval
       }

Raftus & Cardona Standards Track [Page 52] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 docsIfCmCmtsAddress OBJECT-TYPE
      SYNTAX      MacAddress
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Identifies the CMTS that is believed to control this MAC
           domain.  At the CM, this will be the source address from
           SYNC, MAP, and other MAC-layer messages.  If the CMTS is
           unknown, returns 00-00-00-00-00-00."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.2.2."
      ::= { docsIfCmMacEntry 1 }
 docsIfCmCapabilities OBJECT-TYPE
      SYNTAX      BITS {
          atmCells(0),
          concatenation(1)
      }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Identifies the capabilities of the MAC implementation
           at this interface.  Note that packet transmission is
           always supported.  Therefore, there is no specific bit
           required to explicitly indicate this capability.
           Note that BITS objects are encoded most significant bit
           first.  For example, if bit 1 is set, the value of this
           object is the octet string '40'H."
      ::= { docsIfCmMacEntry 2 }
 docsIfCmRangingRespTimeout OBJECT-TYPE
      SYNTAX      TimeTicks
      MAX-ACCESS  read-write
      STATUS      obsolete
      DESCRIPTION
          "Waiting time for a Ranging Response packet.
           This object has been obsoleted and replaced by
           docsIfCmRangingTimeout to correct the typing to
           TimeInterval."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.1.6."
      DEFVAL { 20 }
      ::= { docsIfCmMacEntry 3 }

Raftus & Cardona Standards Track [Page 53] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 docsIfCmRangingTimeout OBJECT-TYPE
      SYNTAX      TimeInterval
      UNITS       "HundredOfSeconds"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "Waiting time for a Ranging Response packet.
           This object MUST NOT persist at reinitialization
           of the managed system."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.1.6, timer T3."
      DEFVAL { 20 }
      ::= { docsIfCmMacEntry 4 }
  1. -
  2. - CM status table.
  3. - This table is implemented only at the CM.
  4. -
 docsIfCmStatusTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table maintains a number of status objects
           and counters for Cable Modems."
      ::= { docsIfCmObjects 2 }
 docsIfCmStatusEntry OBJECT-TYPE
      SYNTAX      DocsIfCmStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "A set of status objects and counters for a single MAC
           layer instance in Cable Modem.
           An entry in this table exists for each ifEntry with an
           ifType of docsCableMaclayer(127)."
      INDEX { ifIndex }
      ::= { docsIfCmStatusTable 1 }
 DocsIfCmStatusEntry ::= SEQUENCE {
          docsIfCmStatusValue               INTEGER,
          docsIfCmStatusCode                OCTET STRING,
          docsIfCmStatusTxPower             TenthdBmV,
          docsIfCmStatusResets              Counter32,
          docsIfCmStatusLostSyncs           Counter32,

Raftus & Cardona Standards Track [Page 54] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          docsIfCmStatusInvalidMaps         Counter32,
          docsIfCmStatusInvalidUcds         Counter32,
          docsIfCmStatusInvalidRangingResponses   Counter32,
          docsIfCmStatusInvalidRegistrationResponses Counter32,
          docsIfCmStatusT1Timeouts          Counter32,
          docsIfCmStatusT2Timeouts          Counter32,
          docsIfCmStatusT3Timeouts          Counter32,
          docsIfCmStatusT4Timeouts          Counter32,
          docsIfCmStatusRangingAborteds     Counter32,
          docsIfCmStatusDocsisOperMode      DocsisQosVersion,
          docsIfCmStatusModulationType      DocsisUpstreamType,
          docsIfCmStatusEqualizationData    DocsEqualizerData,
          docsIfCmStatusUCCs                Counter32,
          docsIfCmStatusUCCFails            Counter32
      }
 docsIfCmStatusValue OBJECT-TYPE
      SYNTAX      INTEGER {
          other(1),
          notReady(2),
          notSynchronized(3),
          phySynchronized(4),
          usParametersAcquired(5),
          rangingComplete(6),
          ipComplete(7),
          todEstablished(8),
          securityEstablished(9),
          paramTransferComplete(10),
          registrationComplete(11),
          operational(12),
          accessDenied(13)
      }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current Cable Modem connectivity state, as specified
           in the RF Interface Specification.  Interpretations for
           state values 1-12 are clearly outlined in the SP-RFI
           reference given below.
           The state value accessDenied(13) indicates the CMTS has
           sent a Registration Aborted message to the CM.  The same
           state is reported as accessDenied(7) by the CMTS object
           docsIfCmtsCmStatusValue."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 11.2.
           Data-Over-Cable Service Interface Specifications:

Raftus & Cardona Standards Track [Page 55] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Operations Support System Interface Specification
           SP-OSSIv2.0-I09-050812, Section 6.3.4.2."
      ::= { docsIfCmStatusEntry 1 }
 docsIfCmStatusCode OBJECT-TYPE
      SYNTAX      OCTET STRING (SIZE( 0 | 5 | 6 ))
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Status code for a Cable Modem as defined in the
           OSSI Specification.  The status code consists
           of a single character indicating error groups, followed
           by a two- or three-digit number indicating the status
           condition, followed by a decimal.
           An example of a returned value could be 'T101.0'.
           The zero-length OCTET STRING indicates no status code yet
           registered."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications:
           Operations Support System Interface Specification
           SP-OSSIv2.0-I09-050812, Annex D."
      ::= { docsIfCmStatusEntry 2 }
 docsIfCmStatusTxPower OBJECT-TYPE
      SYNTAX      TenthdBmV
      UNITS       "TenthdBmV"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The operational transmit power for the attached upstream
           channel."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.18."
      ::= { docsIfCmStatusEntry 3 }
 docsIfCmStatusResets OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "resets"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times the CM reset or initialized this
           interface.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other

Raftus & Cardona Standards Track [Page 56] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmStatusEntry 4 }
 docsIfCmStatusLostSyncs OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times the CM lost synchronization with
           the downstream channel.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.2."
      ::= { docsIfCmStatusEntry 5 }
 docsIfCmStatusInvalidMaps OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "maps"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times the CM received invalid MAP messages.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.4."
      ::= { docsIfCmStatusEntry 6 }
 docsIfCmStatusInvalidUcds OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "messages"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times the CM received invalid UCD messages.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of

Raftus & Cardona Standards Track [Page 57] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.3."
      ::= { docsIfCmStatusEntry 7 }
 docsIfCmStatusInvalidRangingResponses OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "messages"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times the CM received invalid ranging response
           messages.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.6."
      ::= { docsIfCmStatusEntry 8 }
 docsIfCmStatusInvalidRegistrationResponses OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "messages"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times the CM received invalid registration
           response messages.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.8."
      ::= { docsIfCmStatusEntry 9 }
 docsIfCmStatusT1Timeouts OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "timeouts"
      MAX-ACCESS  read-only
      STATUS      current

Raftus & Cardona Standards Track [Page 58] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      DESCRIPTION
          "Number of times counter T1 expired in the CM.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Figure 9-2."
      ::= { docsIfCmStatusEntry 10 }
 docsIfCmStatusT2Timeouts OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "timeouts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times counter T2 expired in the CM.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Figure 9-2."
      ::= { docsIfCmStatusEntry 11 }
 docsIfCmStatusT3Timeouts OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "timeouts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times counter T3 expired in the CM.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Figure 9-2."
      ::= { docsIfCmStatusEntry 12 }
 docsIfCmStatusT4Timeouts OBJECT-TYPE
      SYNTAX      Counter32

Raftus & Cardona Standards Track [Page 59] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      UNITS       "timeouts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times counter T4 expired in the CM.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Figure 9-2."
      ::= { docsIfCmStatusEntry 13 }
 docsIfCmStatusRangingAborteds OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "attempts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Number of times the ranging process was aborted
           by the CMTS.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.3.3."
      ::= { docsIfCmStatusEntry 14 }
 docsIfCmStatusDocsisOperMode OBJECT-TYPE
      SYNTAX      DocsisQosVersion
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
           "Indication of whether the device has registered using 1.0
            Class of Service or 1.1 Quality of Service.
            An unregistered CM SHOULD indicate 'docsis11' for a
            docsIfDocsisBaseCapability value of DOCSIS 1.1/2.0.  An
            unregistered CM SHOULD indicate 'docsis10'  for a
            docsIfDocsisBaseCapability value of DOCSIS 1.0."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Annex G."

Raftus & Cardona Standards Track [Page 60] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      ::= { docsIfCmStatusEntry 15 }
 docsIfCmStatusModulationType OBJECT-TYPE
       SYNTAX      DocsisUpstreamType
       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "Indicates modulation type status currently used by the
            CM.  Since this object specifically identifies PHY mode,
            the shared upstream channel type is not permitted."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.1."
       ::= { docsIfCmStatusEntry 16 }
 docsIfCmStatusEqualizationData OBJECT-TYPE
      SYNTAX      DocsEqualizerData
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Pre-equalization data for this CM after convolution with
           data indicated in the RNG-RSP.  This data is valid when
           docsIfUpChannelPreEqEnable is set to true."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Figure 8-23."
      ::= { docsIfCmStatusEntry 17 }
 docsIfCmStatusUCCs OBJECT-TYPE
      SYNTAX          Counter32
      UNITS           "attempts"
      MAX-ACCESS      read-only
      STATUS          current
      DESCRIPTION
          "The number of successful Upstream Channel Change
           transactions.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmStatusEntry 18 }
 docsIfCmStatusUCCFails OBJECT-TYPE
      SYNTAX          Counter32
      UNITS           "attempts"

Raftus & Cardona Standards Track [Page 61] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      MAX-ACCESS      read-only
      STATUS          current
      DESCRIPTION
          "The number of failed Upstream Channel Change
           transactions.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmStatusEntry 19 }
  1. -
  2. - The Cable Modem Service Table
  3. -
 docsIfCmServiceTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmServiceEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Describes the attributes of each upstream service queue
           on a CM."
      ::= { docsIfCmObjects 3 }
 docsIfCmServiceEntry OBJECT-TYPE
      SYNTAX      DocsIfCmServiceEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Describes the attributes of an upstream bandwidth service
           queue.
           An entry in this table exists for each Service ID.
           The primary index is an ifIndex with an ifType of
           docsCableMaclayer(127)."
      INDEX { ifIndex, docsIfCmServiceId }
      ::= { docsIfCmServiceTable 1 }
 DocsIfCmServiceEntry ::= SEQUENCE {
          docsIfCmServiceId               Integer32,
          docsIfCmServiceQosProfile       Integer32,
          docsIfCmServiceTxSlotsImmed     Counter32,
          docsIfCmServiceTxSlotsDed       Counter32,
          docsIfCmServiceTxRetries        Counter32,
          docsIfCmServiceTxExceededs      Counter32,
          docsIfCmServiceRqRetries        Counter32,
          docsIfCmServiceRqExceededs      Counter32,
          docsIfCmServiceExtTxSlotsImmed  Counter64,
          docsIfCmServiceExtTxSlotsDed    Counter64

Raftus & Cardona Standards Track [Page 62] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

       }
 docsIfCmServiceId OBJECT-TYPE
      SYNTAX      Integer32 (1..16383)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Identifies a service queue for upstream bandwidth.  The
           attributes of this service queue are shared between the
           CM and the CMTS.  The CMTS allocates upstream bandwidth
           to this service queue based on requests from the CM and
           on the class of service associated with this queue."
      ::= { docsIfCmServiceEntry 1 }
 docsIfCmServiceQosProfile OBJECT-TYPE
      SYNTAX      Integer32 (0..16383)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The index in docsIfQosProfileTable describing the quality
           of service attributes associated with this particular
           service.  If no associated entry in docsIfQosProfileTable
           exists, this object returns a value of zero."
      ::= { docsIfCmServiceEntry 2 }
 docsIfCmServiceTxSlotsImmed OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of upstream mini-slots that have been used to
           transmit data PDUs in immediate (contention) mode.  This
           includes only those PDUs that are presumed to have
           arrived at the head-end (i.e., those that were explicitly
           acknowledged).  It does not include retransmission attempts
           or mini-slots used by requests.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.4."
      ::= { docsIfCmServiceEntry 3 }
 docsIfCmServiceTxSlotsDed OBJECT-TYPE

Raftus & Cardona Standards Track [Page 63] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of upstream mini-slots that have been used to
           transmit data PDUs in dedicated mode (i.e., as a result
           of a unicast Data Grant).
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.4."
      ::= { docsIfCmServiceEntry 4 }
 docsIfCmServiceTxRetries OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "attempts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of attempts to transmit data PDUs containing
           requests for acknowledgment that did not result in
           acknowledgment.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.4."
      ::= { docsIfCmServiceEntry 5 }
 docsIfCmServiceTxExceededs OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "attempts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of data PDU transmission failures due to
           excessive retries without acknowledgment.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of

Raftus & Cardona Standards Track [Page 64] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.4."
      ::= { docsIfCmServiceEntry 6 }
 docsIfCmServiceRqRetries OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "attempts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of attempts to transmit bandwidth requests
           that did not result in acknowledgment.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.4."
      ::= { docsIfCmServiceEntry 7 }
 docsIfCmServiceRqExceededs OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "attempts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of requests for bandwidth that failed due to
           excessive retries without acknowledgment.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.4."
      ::= { docsIfCmServiceEntry 8 }
 docsIfCmServiceExtTxSlotsImmed OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current

Raftus & Cardona Standards Track [Page 65] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      DESCRIPTION
          "The number of upstream mini-slots that have been used to
           transmit data PDUs in immediate (contention) mode.  This
           includes only those PDUs that are presumed to have
           arrived at the head-end (i.e., those that were explicitly
           acknowledged).  It does not include retransmission attempts
           or mini-slots used by requests.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.4."
      ::= { docsIfCmServiceEntry 9 }
 docsIfCmServiceExtTxSlotsDed OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of upstream mini-slots that have been used to
           transmit data PDUs in dedicated mode (i.e., as a result
           of a unicast Data Grant).
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.4."
      ::= { docsIfCmServiceEntry 10 }
  1. -
  2. - CMTS GROUP
  3. -
  1. -
  2. - The CMTS MAC Table
  3. -
 docsIfCmtsMacTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmtsMacEntry
      MAX-ACCESS  not-accessible
      STATUS      current

Raftus & Cardona Standards Track [Page 66] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      DESCRIPTION
          "Describes the attributes of each CMTS MAC interface,
           extending the information available from ifEntry.
           Mandatory for all CMTS devices."
      ::= { docsIfCmtsObjects 1 }
 docsIfCmtsMacEntry OBJECT-TYPE
      SYNTAX      DocsIfCmtsMacEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "An entry containing objects describing attributes of each
           MAC entry, extending the information in ifEntry.
           An entry in this table exists for each ifEntry with an
           ifType of docsCableMaclayer(127)."
      INDEX { ifIndex }
      ::= { docsIfCmtsMacTable 1 }
 DocsIfCmtsMacEntry ::= SEQUENCE {
          docsIfCmtsCapabilities            BITS,
          docsIfCmtsSyncInterval            Integer32,
          docsIfCmtsUcdInterval             Integer32,
          docsIfCmtsMaxServiceIds           Integer32,
          docsIfCmtsInsertionInterval       TimeTicks,   -- Obsolete
          docsIfCmtsInvitedRangingAttempts  Integer32,
          docsIfCmtsInsertInterval          TimeInterval,
          docsIfCmtsMacStorageType          StorageType
      }
 docsIfCmtsCapabilities OBJECT-TYPE
      SYNTAX      BITS {
          atmCells(0),
          concatenation(1)
      }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Identifies the capabilities of the CMTS MAC
           implementation at this interface.  Note that packet
           transmission is always supported.  Therefore, there
           is no specific bit required to explicitly indicate
           this capability.
           Note that BITS objects are encoded most significant bit
           first.  For example, if bit 1 is set, the value of this
           object is the octet string '40'H."
      ::= { docsIfCmtsMacEntry 1 }
 docsIfCmtsSyncInterval OBJECT-TYPE

Raftus & Cardona Standards Track [Page 67] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      SYNTAX      Integer32 (1..200)
      UNITS       "Milliseconds"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "The interval between CMTS transmission of successive SYNC
           messages at this interface."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.3."
      ::= { docsIfCmtsMacEntry 2 }
 docsIfCmtsUcdInterval OBJECT-TYPE
      SYNTAX      Integer32 (1..2000)
      UNITS       "Milliseconds"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "The interval between CMTS transmission of successive
           Upstream Channel Descriptor messages for each upstream
           channel at this interface."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.3"
      ::= { docsIfCmtsMacEntry 3 }
 docsIfCmtsMaxServiceIds OBJECT-TYPE
      SYNTAX     Integer32 (1..16383)
      UNITS      "SIDs"
      MAX-ACCESS read-only
      STATUS     current
      DESCRIPTION
          "The maximum number of service IDs that may be
           simultaneously active."
      ::= { docsIfCmtsMacEntry 4 }
 docsIfCmtsInsertionInterval OBJECT-TYPE
      SYNTAX      TimeTicks
      MAX-ACCESS  read-write
      STATUS      obsolete
      DESCRIPTION
          "The amount of time to elapse between each broadcast
           initial maintenance grant.  Broadcast initial maintenance
           grants are used to allow new cable modems to join the
           network.  Zero indicates that a vendor-specific algorithm
           is used instead of a fixed time.  The maximum amount of

Raftus & Cardona Standards Track [Page 68] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           time permitted by the specification is 2 seconds.
           This object has been obsoleted and replaced by
           docsIfCmtsInsertInterval to fix a SYNTAX typing problem."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Annex B."
      ::= { docsIfCmtsMacEntry 5 }
 docsIfCmtsInvitedRangingAttempts OBJECT-TYPE
      SYNTAX      Integer32 (0..1024)
      UNITS      "attempts"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "The maximum number of attempts to make on invitations
           for ranging requests.  A value of zero means the system
           SHOULD attempt to range forever."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 9.3.3 and Annex B."
      ::= { docsIfCmtsMacEntry 6 }
 docsIfCmtsInsertInterval OBJECT-TYPE
      SYNTAX      TimeInterval
      UNITS       "HundredOfSeconds"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "The amount of time to elapse between each broadcast
           initial maintenance grant.  Broadcast initial maintenance
           grants are used to allow new cable modems to join the
           network.  Zero indicates that a vendor-specific algorithm
           is used instead of a fixed time.  The maximum amount of
           time permitted by the specification is 2 seconds."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Annex B."
      ::= { docsIfCmtsMacEntry 7 }
 docsIfCmtsMacStorageType OBJECT-TYPE
      SYNTAX       StorageType
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
          "The storage type for this conceptual row.

Raftus & Cardona Standards Track [Page 69] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Entries with this object set to permanent(4)
           do not require write operations for read-write
           objects."
      ::= { docsIfCmtsMacEntry 8 }
  1. -
  2. -
  3. - CMTS status table.
  4. -
 docsIfCmtsStatusTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmtsStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "For the MAC layer, this group maintains a number of
           status objects and counters."
      ::= { docsIfCmtsObjects 2 }
 docsIfCmtsStatusEntry OBJECT-TYPE
      SYNTAX      DocsIfCmtsStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
         "Status entry for a single MAC layer.
           An entry in this table exists for each ifEntry with an
           ifType of docsCableMaclayer(127)."
      INDEX { ifIndex }
      ::= { docsIfCmtsStatusTable 1 }
 DocsIfCmtsStatusEntry ::= SEQUENCE {
          docsIfCmtsStatusInvalidRangeReqs        Counter32,
          docsIfCmtsStatusRangingAborteds         Counter32,
          docsIfCmtsStatusInvalidRegReqs          Counter32,
          docsIfCmtsStatusFailedRegReqs           Counter32,
          docsIfCmtsStatusInvalidDataReqs         Counter32,
          docsIfCmtsStatusT5Timeouts              Counter32
      }
 docsIfCmtsStatusInvalidRangeReqs OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "messages"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This object counts invalid RNG-REQ messages received on
           this interface.
           Discontinuities in the value of this counter can occur

Raftus & Cardona Standards Track [Page 70] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.5."
      ::= { docsIfCmtsStatusEntry 1 }
 docsIfCmtsStatusRangingAborteds OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "attempts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This object counts ranging attempts that were explicitly
           aborted by the CMTS.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.6."
      ::= { docsIfCmtsStatusEntry 2 }
 docsIfCmtsStatusInvalidRegReqs OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "messages"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This object counts invalid REG-REQ messages received on
           this interface; that is, syntax, out of range parameters,
           or erroneous requests.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.7."
      ::= { docsIfCmtsStatusEntry 3 }
 docsIfCmtsStatusFailedRegReqs OBJECT-TYPE
      SYNTAX      Counter32

Raftus & Cardona Standards Track [Page 71] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      UNITS       "attempts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This object counts failed registration attempts.  Included
           are docsIfCmtsStatusInvalidRegReqs, authentication, and
           class of service failures.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.3.7."
      ::= { docsIfCmtsStatusEntry 4 }
 docsIfCmtsStatusInvalidDataReqs OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "messages"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This object counts invalid data request messages
           received on this interface.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsStatusEntry 5 }
 docsIfCmtsStatusT5Timeouts OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "timeouts"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "This object counts the number of times counter T5
           expired on this interface.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Figure 9-2."
      ::= { docsIfCmtsStatusEntry 6 }

Raftus & Cardona Standards Track [Page 72] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

  1. -
  2. - CM status table (within CMTS).
  3. - This table is implemented only at the CMTS.
  4. - It contains per-CM status information available in the CMTS.
  5. -
 docsIfCmtsCmStatusTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmtsCmStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "A set of objects in the CMTS, maintained for each
           cable modem connected to this CMTS."
      ::= { docsIfCmtsObjects 3 }
 docsIfCmtsCmStatusEntry OBJECT-TYPE
      SYNTAX      DocsIfCmtsCmStatusEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Status information for a single cable modem.
           An entry in this table exists for each cable modem
           that is connected to the CMTS implementing this table."
      INDEX { docsIfCmtsCmStatusIndex }
      ::= { docsIfCmtsCmStatusTable 1 }
 DocsIfCmtsCmStatusEntry ::= SEQUENCE {
          docsIfCmtsCmStatusIndex               Integer32,
          docsIfCmtsCmStatusMacAddress          MacAddress,
          docsIfCmtsCmStatusIpAddress        IpAddress, -- deprecated
          docsIfCmtsCmStatusDownChannelIfIndex  InterfaceIndexOrZero,
          docsIfCmtsCmStatusUpChannelIfIndex    InterfaceIndexOrZero,
          docsIfCmtsCmStatusRxPower             TenthdBmV,
          docsIfCmtsCmStatusTimingOffset        Unsigned32,
          docsIfCmtsCmStatusEqualizationData    DocsEqualizerData,
          docsIfCmtsCmStatusValue               INTEGER,
          docsIfCmtsCmStatusUnerroreds          Counter32,
          docsIfCmtsCmStatusCorrecteds          Counter32,
          docsIfCmtsCmStatusUncorrectables      Counter32,
          docsIfCmtsCmStatusSignalNoise         TenthdB,
          docsIfCmtsCmStatusMicroreflections    Integer32,
          docsIfCmtsCmStatusExtUnerroreds       Counter64,
          docsIfCmtsCmStatusExtCorrecteds       Counter64,
          docsIfCmtsCmStatusExtUncorrectables   Counter64,
          docsIfCmtsCmStatusDocsisRegMode       DocsisQosVersion,
          docsIfCmtsCmStatusModulationType      DocsisUpstreamType,
          docsIfCmtsCmStatusInetAddressType     InetAddressType,
          docsIfCmtsCmStatusInetAddress         InetAddress,

Raftus & Cardona Standards Track [Page 73] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          docsIfCmtsCmStatusValueLastUpdate     TimeStamp,
          docsIfCmtsCmStatusHighResolutionTimingOffset Unsigned32
      }
 docsIfCmtsCmStatusIndex OBJECT-TYPE
      SYNTAX      Integer32 (1..2147483647)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Index value to uniquely identify an entry in this table.
           For an individual cable modem, this index value SHOULD
           NOT change during CMTS uptime."
      ::= { docsIfCmtsCmStatusEntry 1 }
 docsIfCmtsCmStatusMacAddress OBJECT-TYPE
      SYNTAX      MacAddress
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "MAC address of the cable modem.  If the cable modem has
           multiple MAC addresses, this is the MAC address associated
           with the Cable interface."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 8.2.2."
      ::= { docsIfCmtsCmStatusEntry 2 }
 docsIfCmtsCmStatusIpAddress OBJECT-TYPE
      SYNTAX      IpAddress
      MAX-ACCESS  read-only
      STATUS      deprecated
      DESCRIPTION
          "IP address of this cable modem.  If the cable modem has no
           IP address assigned, or the IP address is unknown, this
           object returns a value of 0.0.0.0.  If the cable modem has
           multiple IP addresses, this object returns the IP address
           associated with the Cable interface.
           This object has been deprecated and replaced by
           docsIfCmtsCmStatusInetAddressType and
           docsIfCmtsCmStatusInetAddress, to enable IPv6 addressing
           in the future."
      ::= { docsIfCmtsCmStatusEntry 3 }
 docsIfCmtsCmStatusDownChannelIfIndex OBJECT-TYPE
      SYNTAX      InterfaceIndexOrZero
      MAX-ACCESS  read-only
      STATUS      current

Raftus & Cardona Standards Track [Page 74] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      DESCRIPTION
          "IfIndex of the downstream channel that this CM is
           connected to.  If the downstream channel is unknown, this
           object returns a value of zero."
      ::= { docsIfCmtsCmStatusEntry 4 }
 docsIfCmtsCmStatusUpChannelIfIndex OBJECT-TYPE
      SYNTAX      InterfaceIndexOrZero
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
         "For DOCSIS 2.0, indicates the ifIndex of the logical
          upstream channel (ifType 205) this CM is connected to.
          For DOCSIS 1.x, indicates the ifIndex of the upstream
           channel (ifType 129) this CM is connected to.
           If the upstream channel is unknown, this object
           returns a value of zero."
      ::= { docsIfCmtsCmStatusEntry 5 }
 docsIfCmtsCmStatusRxPower OBJECT-TYPE
      SYNTAX      TenthdBmV
      UNITS       "ThenthdBmV"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The receive power as perceived for upstream data from
           this cable modem.
           If the receive power is unknown, this object returns
           a value of zero."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.18."
      ::= { docsIfCmtsCmStatusEntry 6 }
 docsIfCmtsCmStatusTimingOffset OBJECT-TYPE
      SYNTAX      Unsigned32 (0..4294967295)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "A measure of the current round trip time for this CM.
           Used for timing of CM upstream transmissions to ensure
           synchronized arrivals at the CMTS.  Units are in terms
           of (6.25 microseconds/64).  Returns zero if the value
           is unknown.
           For channels requiring finer resolution, please refer to
           object docsIfCmtsCmStatusHighResolutionTimingOffset."
      REFERENCE

Raftus & Cardona Standards Track [Page 75] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.17."
      ::= { docsIfCmtsCmStatusEntry 7 }
 docsIfCmtsCmStatusEqualizationData OBJECT-TYPE
      SYNTAX      DocsEqualizerData
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Equalization data for this CM, as measured by the CMTS.
           Returns the zero-length OCTET STRING if the value is
           unknown or if there is no equalization data available
           or defined."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Figure 8-23."
      ::= { docsIfCmtsCmStatusEntry 8 }
 docsIfCmtsCmStatusValue OBJECT-TYPE
      SYNTAX      INTEGER {
          other(1),
          ranging(2),
          rangingAborted(3),
          rangingComplete(4),
          ipComplete(5),
          registrationComplete(6),
          accessDenied(7),
          operational(8),
          -- value 8 should not be used
          registeredBPIInitializing(9)
      }
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current cable modem connectivity state, as specified
           in the RF Interface Specification.  Returned status
           information is the CM status, as assumed by the CMTS,
           and indicates the following events:
           other(1)
              Any state other than below.
           ranging(2)
              The CMTS has received an Initial Ranging Request
              message from the CM, and the ranging process is not
              yet complete.
           rangingAborted(3)
              The CMTS has sent a Ranging Abort message to the CM.

Raftus & Cardona Standards Track [Page 76] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           rangingComplete(4)
              The CMTS has sent a Ranging Complete message to the CM.
           ipComplete(5)
              The CMTS has received a DHCP reply message and
              forwarded it to the CM.
           registrationComplete(6)
              The CMTS has sent a Registration Response message to
              the CM.
           accessDenied(7)
              The CMTS has sent a Registration Aborted message
              to the CM.
           operational(8)
              Value 8 is considered reserved and should not be defined
              in future revisions of this MIB module to avoid conflict
              with documented implementations that support value 8 to
              indicate operational state after completing the BPI
              initialization process.
           registeredBPIInitializing(9)
              Baseline Privacy (BPI) is enabled and the CMTS is in the
              process of completing BPI initialization.  This state
              MAY last for a significant length of time if failures
              occur during the initialization process.  After
              completion of BPI initialization, the CMTS will report
              registrationComplete(6).
           The CMTS only needs to report states it is able to
           detect."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 11.2."
      ::= { docsIfCmtsCmStatusEntry 9 }
 docsIfCmtsCmStatusUnerroreds OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received without error from this cable modem.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.4."
      ::= { docsIfCmtsCmStatusEntry 10 }

Raftus & Cardona Standards Track [Page 77] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 docsIfCmtsCmStatusCorrecteds OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received with correctable errors from this
           cable modem.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.4."
      ::= { docsIfCmtsCmStatusEntry 11 }
 docsIfCmtsCmStatusUncorrectables OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received with uncorrectable errors from this
           cable modem.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.4."
      ::= { docsIfCmtsCmStatusEntry 12 }
 docsIfCmtsCmStatusSignalNoise OBJECT-TYPE
      SYNTAX      TenthdB
      UNITS       "TenthdB"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Signal/Noise ratio as perceived for upstream data from
           this cable modem.
           If the Signal/Noise is unknown, this object returns
           a value of zero."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio

Raftus & Cardona Standards Track [Page 78] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 4-1 and 4-2."
      ::= { docsIfCmtsCmStatusEntry 13 }
 docsIfCmtsCmStatusMicroreflections OBJECT-TYPE
      SYNTAX      Integer32 (0..255)
      UNITS       "-dBc"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Total microreflections, including in-channel response
           as perceived on this interface, measured in dBc below
           the signal level.
           This object is not assumed to return an absolutely
           accurate value, but it gives a rough indication
           of microreflections received on this interface.
           It is up to the implementer to provide information
           as accurately as possible.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 4-1 and 4-2"
      ::= { docsIfCmtsCmStatusEntry 14 }
 docsIfCmtsCmStatusExtUnerroreds OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received without error from this cable modem.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.5."
      ::= { docsIfCmtsCmStatusEntry 15 }
 docsIfCmtsCmStatusExtCorrecteds OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "codewords"

Raftus & Cardona Standards Track [Page 79] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received with correctable errors from this
           cable modem.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.5."
      ::= { docsIfCmtsCmStatusEntry 16 }
 docsIfCmtsCmStatusExtUncorrectables OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "codewords"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Codewords received with uncorrectable errors from this
           cable modem.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.5."
      ::= { docsIfCmtsCmStatusEntry 17 }
 docsIfCmtsCmStatusDocsisRegMode OBJECT-TYPE
         SYNTAX      DocsisQosVersion
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
             "Indication of whether the CM has registered using 1.0
              Class of Service or 1.1 Quality of Service."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Annex G."
      ::= { docsIfCmtsCmStatusEntry 18 }
 docsIfCmtsCmStatusModulationType OBJECT-TYPE
       SYNTAX      DocsisUpstreamType

Raftus & Cardona Standards Track [Page 80] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

       MAX-ACCESS  read-only
       STATUS      current
       DESCRIPTION
           "Indicates modulation type currently used by the CM.  Since
            this object specifically identifies PHY mode, the shared
            type is not permitted.  If the upstream channel is
            unknown, this object returns a value of zero."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 8-19."
       ::= { docsIfCmtsCmStatusEntry 19 }
 docsIfCmtsCmStatusInetAddressType OBJECT-TYPE
         SYNTAX      InetAddressType
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
             "The type of internet address of
              docsIfCmtsCmStatusInetAddress.  If the cable modem
              internet address is unassigned or unknown, then the
              value of this object is unknown(0)."
         ::= { docsIfCmtsCmStatusEntry 20 }
 docsIfCmtsCmStatusInetAddress OBJECT-TYPE
         SYNTAX      InetAddress
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
             "Internet address of this cable modem.  If the Cable
              Modem has no Internet address assigned, or the Internet
              address is unknown, the value of this object is the
              zero-length OCTET STRING.  If the cable modem has
              multiple Internet addresses, this object returns the
              Internet address associated with the Cable
              (i.e., RF MAC) interface."
         ::= { docsIfCmtsCmStatusEntry 21 }
 docsIfCmtsCmStatusValueLastUpdate OBJECT-TYPE
         SYNTAX      TimeStamp
         MAX-ACCESS  read-only
         STATUS      current
         DESCRIPTION
             "The value of sysUpTime when docsIfCmtsCmStatusValue
              was last updated."
         ::= { docsIfCmtsCmStatusEntry 22 }
 docsIfCmtsCmStatusHighResolutionTimingOffset OBJECT-TYPE

Raftus & Cardona Standards Track [Page 81] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      SYNTAX      Unsigned32 (0..4294967295)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "A measure of the current round trip time for this CM.
           Used for timing of CM upstream transmissions to ensure
           synchronized arrivals at the CMTS.  Units are in terms
           of (6.25 microseconds/(64*256)).  Returns zero if the value
           is unknown.
           This is the high resolution version of object
           docsIfCmtsCmStatusTimingOffset, for channels requiring
           finer resolution."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Section 6.2.17."
      ::= { docsIfCmtsCmStatusEntry 23 }
  1. -
  2. - The CMTS Service Table.
  3. -
 docsIfCmtsServiceTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmtsServiceEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Describes the attributes of upstream service queues
           in a Cable Modem Termination System."
      ::= { docsIfCmtsObjects 4 }
 docsIfCmtsServiceEntry OBJECT-TYPE
      SYNTAX      DocsIfCmtsServiceEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Describes the attributes of a single upstream bandwidth
           service queue.
           Entries in this table exist for each ifEntry with an
           ifType of docsCableMaclayer(127), and for each service
           queue (Service ID) within this MAC layer.
           Entries in this table are created with the creation of
           individual Service IDs by the MAC layer and removed
           when a Service ID is removed."
      INDEX { ifIndex, docsIfCmtsServiceId }
      ::= { docsIfCmtsServiceTable 1 }
 DocsIfCmtsServiceEntry ::= SEQUENCE {

Raftus & Cardona Standards Track [Page 82] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          docsIfCmtsServiceId               Integer32,
          docsIfCmtsServiceCmStatusIndex    Integer32,  -- deprecated
          docsIfCmtsServiceAdminStatus      INTEGER,
          docsIfCmtsServiceQosProfile       Integer32,
          docsIfCmtsServiceCreateTime       TimeStamp,
          docsIfCmtsServiceInOctets         Counter32,
          docsIfCmtsServiceInPackets        Counter32,
          docsIfCmtsServiceNewCmStatusIndex Integer32
      }
 docsIfCmtsServiceId OBJECT-TYPE
      SYNTAX      Integer32 (1..16383)
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Identifies a service queue for upstream bandwidth.  The
           attributes of this service queue are shared between the
           Cable Modem and the Cable Modem Termination System.
           The CMTS allocates upstream bandwidth to this service
           queue based on requests from the CM and on the class of
           service associated with this queue."
      ::= { docsIfCmtsServiceEntry 1 }
 docsIfCmtsServiceCmStatusIndex OBJECT-TYPE
      SYNTAX      Integer32 (0..65535)
      MAX-ACCESS  read-only
      STATUS      deprecated
      DESCRIPTION
          "Pointer to an entry in docsIfCmtsCmStatusTable identifying
           the cable modem using this Service Queue.  If multiple
           cable modems are using this Service Queue, the value of
           this object is zero.
           This object has been deprecated and replaced by
           docsIfCmtsServiceNewCmStatusIndex, to fix a mismatch
           of the value range with respect to docsIfCmtsCmStatusIndex
           (1..2147483647)."
      ::= { docsIfCmtsServiceEntry 2 }
 docsIfCmtsServiceAdminStatus OBJECT-TYPE
      SYNTAX      INTEGER {
          enabled(1),
          disabled(2),
          destroyed(3) }
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "Allows a service class for a particular modem to be
           suppressed, (re-)enabled, or deleted altogether."

Raftus & Cardona Standards Track [Page 83] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      ::= { docsIfCmtsServiceEntry 3 }
 docsIfCmtsServiceQosProfile OBJECT-TYPE
      SYNTAX      Integer32 (0..16383)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The index in docsIfQosProfileTable describing the quality
           of service attributes associated with this particular
           service.  If no associated docsIfQosProfileTable entry
           exists, this object returns a value of zero."
      ::= { docsIfCmtsServiceEntry 4 }
 docsIfCmtsServiceCreateTime OBJECT-TYPE
      SYNTAX      TimeStamp
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The value of sysUpTime when this entry was created."
      ::= { docsIfCmtsServiceEntry 5 }
 docsIfCmtsServiceInOctets OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "Bytes"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The cumulative number of Packet Data octets received
           on this Service ID.  The count does not include the
           size of the Cable MAC header.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsServiceEntry 6 }
 docsIfCmtsServiceInPackets OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "packets"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The cumulative number of Packet Data packets received
           on this Service ID.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."

Raftus & Cardona Standards Track [Page 84] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      ::= { docsIfCmtsServiceEntry 7 }
 docsIfCmtsServiceNewCmStatusIndex OBJECT-TYPE
      SYNTAX      Integer32 (0..2147483647)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Pointer (via docsIfCmtsCmStatusIndex) to an entry in
           docsIfCmtsCmStatusTable identifying the cable modem
           using this Service Queue.  If multiple cable modems are
           using this Service Queue, the value of this object is
           zero."
      ::= { docsIfCmtsServiceEntry 8 }
  1. -
  2. - The following table provides upstream channel modulation profiles.
  3. - Entries in this table can be
  4. - re-used by one or more upstream channels. An upstream channel
  5. - will have a modulation profile for each value of
  6. - docsIfModIntervalUsageCode.
  7. -
 docsIfCmtsModulationTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmtsModulationEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Describes a modulation profile associated with one or more
           upstream channels."
      ::= { docsIfCmtsObjects 5 }
 docsIfCmtsModulationEntry OBJECT-TYPE
      SYNTAX      DocsIfCmtsModulationEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Describes a modulation profile for an Interval Usage Code
           for one or more upstream channels.
           Entries in this table are created by the operator.
           Initial default entries MAY be created at system
           initialization time, which could report a value of
           'permanent' or 'readOnly' for docsIfCmtsModStorageType.
           A CMTS MAY reject the creation of additional Interval
           Usage Codes for a modulation profile being defined at
           Initialization time.
           No individual objects have to be specified in order
           to create an entry in this table.

Raftus & Cardona Standards Track [Page 85] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Note that some objects do not have DEFVAL clauses
           but do have calculated defaults and need not be specified
           during row creation."
       INDEX { docsIfCmtsModIndex, docsIfCmtsModIntervalUsageCode}
      ::= { docsIfCmtsModulationTable 1 }
 DocsIfCmtsModulationEntry ::= SEQUENCE {
          docsIfCmtsModIndex                    Integer32,
          docsIfCmtsModIntervalUsageCode        INTEGER,
          docsIfCmtsModControl                  RowStatus,
          docsIfCmtsModType                     INTEGER,
          docsIfCmtsModPreambleLen              Integer32,
          docsIfCmtsModDifferentialEncoding     TruthValue,
          docsIfCmtsModFECErrorCorrection       Integer32,
          docsIfCmtsModFECCodewordLength        Integer32,
          docsIfCmtsModScramblerSeed            Integer32,
          docsIfCmtsModMaxBurstSize             Integer32,
          docsIfCmtsModGuardTimeSize            Unsigned32,
          docsIfCmtsModLastCodewordShortened    TruthValue,
          docsIfCmtsModScrambler                TruthValue,
          docsIfCmtsModByteInterleaverDepth     Unsigned32,
          docsIfCmtsModByteInterleaverBlockSize Unsigned32,
          docsIfCmtsModPreambleType             INTEGER,
          docsIfCmtsModTcmErrorCorrectionOn     TruthValue,
          docsIfCmtsModScdmaInterleaverStepSize Unsigned32,
          docsIfCmtsModScdmaSpreaderEnable      TruthValue,
          docsIfCmtsModScdmaSubframeCodes       Unsigned32,
          docsIfCmtsModChannelType              DocsisUpstreamType,
          docsIfCmtsModStorageType              StorageType
      }
 docsIfCmtsModIndex OBJECT-TYPE
      SYNTAX       Integer32 (1..2147483647)
      MAX-ACCESS   not-accessible
      STATUS      current
      DESCRIPTION
           "An index into the Channel Modulation table representing
            a group of Interval Usage Codes, all associated with the
            same channel."
      ::= { docsIfCmtsModulationEntry 1 }
 docsIfCmtsModIntervalUsageCode OBJECT-TYPE
      SYNTAX       INTEGER {
          request(1),
          requestData(2),
          initialRanging(3),
          periodicRanging(4),
          shortData(5),

Raftus & Cardona Standards Track [Page 86] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          longData(6),
          advPhyShortData(9),
          advPhyLongData(10),
          ugs(11)
      }
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "An index into the Channel Modulation table that, when
           grouped with other Interval Usage Codes, fully
           instantiates all modulation sets for a given upstream
           channel."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 8-20."
      ::= { docsIfCmtsModulationEntry 2 }
 docsIfCmtsModControl OBJECT-TYPE
      SYNTAX      RowStatus
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Controls and reflects the status of rows in this table.
           There is no restriction on the changing of values in this
           table while their associated rows are active, with the
           exception of:
           1. If a modulation profile is being referenced by one
              or more upstream channels, an attempt to set the value
              of docsIfCmtsModChannelType returns an
              'inconsistentValue' error.
           2. If a modulation profile is being referenced by one
              or more upstream channels, an attempt to set
              docsIfCmtsModControl to destroy(6) or notInService(2)
              returns an 'inconsistentValue' error."
      ::= { docsIfCmtsModulationEntry 3 }
 docsIfCmtsModType OBJECT-TYPE
      SYNTAX      INTEGER {
          other(1),
          qpsk(2),
          qam16(3),
          qam8(4),
          qam32(5),
          qam64(6),
          qam128(7)

Raftus & Cardona Standards Track [Page 87] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      }
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The modulation type used on this channel.  Returns
           other(1) if the modulation type is not
           qpsk, qam16, qam8, qam32, qam64, or qam128.
           Type qam128 is used for SCDMA channels only.
           See the reference for the modulation profiles
           implied by different modulation types."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { qpsk }
      ::= { docsIfCmtsModulationEntry 4 }
 docsIfCmtsModPreambleLen OBJECT-TYPE
      SYNTAX      Integer32 (0..1536)
      UNITS       "bits"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The preamble length for this modulation profile in bits.
           Default value is the minimum needed by the implementation
           at the CMTS for the given modulation profile."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      ::= { docsIfCmtsModulationEntry 5 }
 docsIfCmtsModDifferentialEncoding OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Specifies whether or not differential encoding is used
           on this channel."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { false }
      ::= { docsIfCmtsModulationEntry 6 }
 docsIfCmtsModFECErrorCorrection OBJECT-TYPE
      SYNTAX      Integer32 (0..16)

Raftus & Cardona Standards Track [Page 88] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      UNITS       "Bytes"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The number of correctable errored bytes (t) used in
           forward error correction code.  The value of 0 indicates
           that no correction is employed.  The number of check bytes
           appended will be twice this value."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { 0 }
      ::= { docsIfCmtsModulationEntry 7 }
 docsIfCmtsModFECCodewordLength OBJECT-TYPE
      SYNTAX      Integer32 (1..255)
      UNITS       "Bytes"
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The number of data bytes (k) in the forward error
           correction codeword.
           This object is not used if docsIfCmtsModFECErrorCorrection
           is zero."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { 32 }
      ::= { docsIfCmtsModulationEntry 8 }
 docsIfCmtsModScramblerSeed OBJECT-TYPE
      SYNTAX      Integer32 (0..32767)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The 15-bit seed value for the scrambler polynomial."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 8-19."
      DEFVAL { 0 }
      ::= { docsIfCmtsModulationEntry 9 }
 docsIfCmtsModMaxBurstSize OBJECT-TYPE
      SYNTAX      Integer32 (0..255)
      UNITS       "mini-slots"

Raftus & Cardona Standards Track [Page 89] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "The maximum number of mini-slots that can be transmitted
           during this channel's burst time.  Returns zero if the
           burst length is bounded by the allocation MAP rather than
           by this profile.
           Default value is 0, except for shortData, where it is 8."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 8-19."
      ::= { docsIfCmtsModulationEntry 10 }
 docsIfCmtsModGuardTimeSize OBJECT-TYPE
      SYNTAX      Unsigned32
      UNITS       "Symbol-times"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The number of symbol-times that MUST follow the end of
           this channel's burst.  Default value is the minimum time
           needed by the implementation for this modulation profile."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      ::= { docsIfCmtsModulationEntry 11 }
 docsIfCmtsModLastCodewordShortened OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Indicates whether the last FEC codeword is truncated."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { true }
      ::= { docsIfCmtsModulationEntry 12 }
 docsIfCmtsModScrambler OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Indicates whether the scrambler is employed."

Raftus & Cardona Standards Track [Page 90] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { false }
      ::= { docsIfCmtsModulationEntry 13 }
 docsIfCmtsModByteInterleaverDepth OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "ATDMA Byte Interleaver Depth (Ir).  This object returns 1
           for non-ATDMA profiles."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { 1 }
      ::= { docsIfCmtsModulationEntry 14 }
 docsIfCmtsModByteInterleaverBlockSize OBJECT-TYPE
      SYNTAX      Unsigned32
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "ATDMA Byte Interleaver Block size (Br).  This object
           returns zero for non-ATDMA profiles "
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { 18 }
      ::= { docsIfCmtsModulationEntry 15 }
 docsIfCmtsModPreambleType OBJECT-TYPE
      SYNTAX       INTEGER {
          unknown(0),
          qpsk0(1),
          qpsk1(2)
      }
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Preamble type for DOCSIS 2.0 bursts.  The value
           'unknown(0)' represents a row entry consisting only of
           DOCSIS 1.x bursts"
      REFERENCE

Raftus & Cardona Standards Track [Page 91] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { qpsk0 }
      ::= { docsIfCmtsModulationEntry 16 }
 docsIfCmtsModTcmErrorCorrectionOn OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Trellis Code Modulation (TCM) On/Off.  This value returns
           false for non-S-CDMA profiles."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { false }
      ::= { docsIfCmtsModulationEntry 17 }
 docsIfCmtsModScdmaInterleaverStepSize OBJECT-TYPE
      SYNTAX      Unsigned32 (0 | 1..32)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          " S-CDMA Interleaver step size.  This value returns zero
            for non-S-CDMA profiles."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      DEFVAL { 1 }
      ::= { docsIfCmtsModulationEntry 18 }
 docsIfCmtsModScdmaSpreaderEnable OBJECT-TYPE
      SYNTAX      TruthValue
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          " S-CDMA spreader.  This value returns false for non-S-CDMA
            profiles.  Default value for IUC 3 and 4 is OFF; for
            all other IUCs it is ON."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Tables 6-7, and 8-19."
      ::= { docsIfCmtsModulationEntry 19 }

Raftus & Cardona Standards Track [Page 92] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 docsIfCmtsModScdmaSubframeCodes OBJECT-TYPE
      SYNTAX      Unsigned32 (0 | 1..128)
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          " S-CDMA sub-frame size.  This value returns zero
            for non-S-CDMA profiles."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 6-7, and 8-19."
      DEFVAL { 1 }
      ::= { docsIfCmtsModulationEntry 20 }
 docsIfCmtsModChannelType OBJECT-TYPE
      SYNTAX      DocsisUpstreamType
      MAX-ACCESS  read-create
      STATUS      current
      DESCRIPTION
          "Describes the modulation channel type for this modulation
           entry.
           All the active entries in a modulation profile (that is all
           active entries that share a common docsIfCmtsModIndex)
           MUST have the same value of docsIfCmtsModChannelType."
      REFERENCE
          "Data-Over-Cable Service Interface Specifications: Radio
           Frequency Interface Specification SP-RFIv2.0-I10-051209,
           Table 8-19."
      DEFVAL { tdma }
      ::= { docsIfCmtsModulationEntry 21 }
 docsIfCmtsModStorageType OBJECT-TYPE
      SYNTAX       StorageType
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
          "The storage type for this conceptual row.
           Entries with this object set to permanent(4)
           do not require write operations for read-write
           objects."
      DEFVAL      { nonVolatile }
  ::= { docsIfCmtsModulationEntry 22 }
 docsIfCmtsQosProfilePermissions OBJECT-TYPE
      SYNTAX      BITS {
          createByManagement(0),
          updateByManagement(1),
          createByModems(2)

Raftus & Cardona Standards Track [Page 93] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      }
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "This object specifies permitted methods of creating
           entries in docsIfQosProfileTable.
           createByManagement(0) is set if entries can be created
           using SNMP.  updateByManagement(1) is set if updating
           entries using SNMP is permitted.  createByModems(2)
           is set if entries can be created based on information
           in REG-REQ MAC messages received from cable modems.
           Information in this object is only applicable if
           docsIfQosProfileTable is implemented as read-create.
           Otherwise, this object is implemented as read-only
           and returns createByModems(2).
           Either createByManagement(0) or updateByManagement(1)
           MUST be set when writing to this object.
           Note that BITS objects are encoded most significant bit
           first.  For example, if bit 2 is set, the value of this
           object is the octet string '20'H."
      ::= { docsIfCmtsObjects 6 }
 docsIfCmtsMacToCmTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmtsMacToCmEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This is a table to provide a quick access index into the
           docsIfCmtsCmStatusTable.  There is exactly one row in this
           table for each row in the docsIfCmtsCmStatusTable.  In
           general, the management station SHOULD use this table only
           to get a pointer into the docsIfCmtsCmStatusTable (which
           corresponds to the CM's RF interface MAC address) and
           SHOULD not iterate (e.g., GetNext through) this table."
      ::= { docsIfCmtsObjects 7 }
 docsIfCmtsMacToCmEntry OBJECT-TYPE
      SYNTAX      DocsIfCmtsMacToCmEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "A row in the docsIfCmtsMacToCmTable.
           An entry in this table exists for each cable modem
           that is connected to the CMTS implementing this table."
      INDEX   { docsIfCmtsCmMac }
      ::= {docsIfCmtsMacToCmTable 1 }
 DocsIfCmtsMacToCmEntry ::= SEQUENCE {

Raftus & Cardona Standards Track [Page 94] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

              docsIfCmtsCmMac     MacAddress,
              docsIfCmtsCmPtr     Integer32
      }
 docsIfCmtsCmMac OBJECT-TYPE
      SYNTAX      MacAddress
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "The RF side MAC address for the referenced CM (e.g., the
           interface on the CM that has docsCableMacLayer(127) as
           its ifType)."
      ::= { docsIfCmtsMacToCmEntry 1 }
 docsIfCmtsCmPtr OBJECT-TYPE
      SYNTAX      Integer32 (1..2147483647)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "An row index into docsIfCmtsCmStatusTable.  When queried
           with the correct instance value (e.g., a CM's MAC address),
           returns the index in docsIfCmtsCmStatusTable that
           represents that CM."
      ::= { docsIfCmtsMacToCmEntry 2 }
  1. - The following independent object and associated table provide
  2. - operators with a mechanism to evaluate the load/utilization of
  3. - both upstream and downstream physical channels. This information
  4. - may be used for capacity planning and incident analysis and may
  5. - be particularly helpful in provisioning of high value QOS.
  6. -
  7. - Utilization is expressed as an index representing the calculated
  8. - percentage utilization of the upstream or downstream channel in
  9. - the most recent sampling interval (i.e., utilization interval).
  10. - Refer to the DESCRIPTION field of the
  11. - docsIfCmtsChannelUtUtilization object for definitions and
  12. - calculation details.
 docsIfCmtsChannelUtilizationInterval OBJECT-TYPE
      SYNTAX      Integer32 (0..86400)
      UNITS       "seconds"
      MAX-ACCESS  read-write
      STATUS      current
      DESCRIPTION
          "The time interval in seconds over which the channel
           utilization index is calculated.  All upstream/downstream
           channels use the same
           docsIfCmtsChannelUtilizationInterval.

Raftus & Cardona Standards Track [Page 95] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           Setting a value of zero disables utilization reporting.
           A channel utilization index is calculated over a fixed
           window applying to the most recent
           docsIfCmtsChannelUtilizationInterval.  It would therefore
           be prudent to use a relatively short
           docsIfCmtsChannelUtilizationInterval.
           It is a vendor decision whether to reset the timer when
           docsIfCmtsChannelUtilizationInterval is changed during a
           utilization sampling period."
      ::= { docsIfCmtsObjects 8 }
 docsIfCmtsChannelUtilizationTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmtsChannelUtilizationEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Reports utilization statistics for attached upstream and
           downstream physical channels."
      ::= { docsIfCmtsObjects 9 }
 docsIfCmtsChannelUtilizationEntry OBJECT-TYPE
      SYNTAX      DocsIfCmtsChannelUtilizationEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "Utilization statistics for a single upstream or downstream
           physical channel.  An entry exists in this table for each
           ifEntry with an ifType equal to
           docsCableDownstream (128)
           or docsCableUpstream (129)."
      INDEX  { ifIndex, docsIfCmtsChannelUtIfType,
           docsIfCmtsChannelUtId }
      ::= { docsIfCmtsChannelUtilizationTable 1 }
 DocsIfCmtsChannelUtilizationEntry ::= SEQUENCE {
          docsIfCmtsChannelUtIfType         IANAifType,
          docsIfCmtsChannelUtId             Integer32,
          docsIfCmtsChannelUtUtilization    Integer32
      }
 docsIfCmtsChannelUtIfType OBJECT-TYPE
      SYNTAX       IANAifType
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION
          "The secondary index into this table.  Indicates the IANA
           interface type associated with this physical channel.
           Only docsCableDownstream (128) and

Raftus & Cardona Standards Track [Page 96] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           docsCableUpstream (129) are valid."
      ::= { docsIfCmtsChannelUtilizationEntry 1 }
 docsIfCmtsChannelUtId OBJECT-TYPE
      SYNTAX       Integer32 (0..255)
      MAX-ACCESS   not-accessible
      STATUS       current
      DESCRIPTION
           "The tertiary index into this table.  Indicates the CMTS
            identifier for this physical channel."
      ::= { docsIfCmtsChannelUtilizationEntry 2 }
 docsIfCmtsChannelUtUtilization OBJECT-TYPE
      SYNTAX       Integer32 (0..100)
      UNITS        "percent"
      MAX-ACCESS   read-only
      STATUS       current
      DESCRIPTION
          "The calculated and truncated utilization index for this
           physical upstream or downstream channel, accurate as of
           the most recent docsIfCmtsChannelUtilizationInterval.
           Upstream Channel Utilization Index:
           The upstream channel utilization index is expressed as a
           percentage of mini-slots utilized on the physical channel,
           regardless of burst type.  For an Initial Maintenance
           region, the mini-slots for the complete region are
           considered utilized if the CMTS received an upstream
           burst within the region from any CM on the physical
           channel.  For contention REQ and REQ/DATA regions, the
           mini-slots for a transmission opportunity within the
           region are considered utilized if the CMTS received an
           upstream burst within the opportunity from any CM on the
           physical channel.  For all other regions, utilized
           mini-slots are those in which the CMTS granted
           bandwidth to any unicast SID on the physical channel.
           For an upstream interface that has multiple logical
           upstream channels enabled, the utilization index is a
           weighted sum of utilization indices for the logical
           channels.  The weight for each utilization index is the
           percentage of upstream mini-slots allocated for the
           corresponding logical channel.
           Example:
           If 75% of bandwidth is allocated to the first logical
           channel and 25% to the second, and the utilization
           indices for each are 60 and 40, respectively, the

Raftus & Cardona Standards Track [Page 97] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           utilization index for the upstream physical channel is
           (60 * 0.75) + (40 * 0.25) = 55.  This figure
           applies to the most recent utilization interval.
           Downstream Channel Utilization Index:
           The downstream channel utilization index is a percentage
           expressing the ratio between bytes used to transmit data
           versus the total number of bytes transmitted in the raw
           bandwidth of the MPEG channel.  As with the upstream
           utilization index, the calculated value represents
           the most recent utilization interval.
           Formula:
           Downstream utilization index =
           (100 * (data bytes / raw bytes))
           Definitions:
           Data bytes:    Number of bytes transmitted as data in the
                          docsIfCmtsChannelUtilizationInterval.
                          Identical to docsIfCmtsDownChannelCtrUsed
                          Bytes measured over the utilization
                          interval.
           Raw bandwidth: Total number of bytes available for
                          transmitting data, not including bytes
                          used for headers and other overhead.
           Raw bytes:     (raw bandwidth *
                          docsIfCmtsChannelUtilizationInterval).
                          Identical to docsIfCmtsDownChannelCtrTotal
                          Bytes measured over the utilization
                          interval."
      ::= { docsIfCmtsChannelUtilizationEntry 3 }
  1. - The following table provides operators with input data
  2. - appropriate for calculating downstream channel utilization.
  3. - Operators may use the docsIfCmtsChannelUtilizationTable or
  4. - perform their own polling of the
  5. - docsIfCmtsDownChannelCounterTable objects to characterize
  6. - their downstream channel usage. The 32-bit counter objects are
  7. - included to provide backward compatibility with SNMPv1 managers,
  8. - which cannot access 64-bit counter objects.
 docsIfCmtsDownChannelCounterTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmtsDownChannelCounterEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table is implemented at the CMTS to collect
           downstream channel statistics for utilization

Raftus & Cardona Standards Track [Page 98] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           calculations."
      ::= { docsIfCmtsObjects 10 }
 docsIfCmtsDownChannelCounterEntry OBJECT-TYPE
      SYNTAX      DocsIfCmtsDownChannelCounterEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "An entry provides a list of traffic counters for a single
           downstream channel.
           An entry in this table exists for each ifEntry with an
           ifType of docsCableDownstream(128)."
      INDEX { ifIndex }
      ::= { docsIfCmtsDownChannelCounterTable 1 }
 DocsIfCmtsDownChannelCounterEntry ::= SEQUENCE {
          docsIfCmtsDownChnlCtrId              Integer32,
          docsIfCmtsDownChnlCtrTotalBytes      Counter32,
          docsIfCmtsDownChnlCtrUsedBytes       Counter32,
          docsIfCmtsDownChnlCtrExtTotalBytes   Counter64,
          docsIfCmtsDownChnlCtrExtUsedBytes    Counter64
      }
 docsIfCmtsDownChnlCtrId OBJECT-TYPE
      SYNTAX      Integer32 (0..255)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The Cable Modem Termination System identification
           of the downstream channel within this particular MAC
           interface.  If the interface is down, the object returns
           the most current value.  If the downstream channel ID is
           unknown, this object returns a value of 0."
      ::= { docsIfCmtsDownChannelCounterEntry 1 }
 docsIfCmtsDownChnlCtrTotalBytes OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "Bytes"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "At the CMTS, the total number of bytes in the Payload
           portion of MPEG Packets (i.e., not including MPEG header
           or pointer_field) transported by this downstream channel.
           This is the 32-bit version of
           docsIfCmtsDownChnlCtrExtTotalBytes, included to provide
           back compatibility with SNMPv1 managers.
           Discontinuities in the value of this counter can occur

Raftus & Cardona Standards Track [Page 99] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsDownChannelCounterEntry 2 }
 docsIfCmtsDownChnlCtrUsedBytes OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "Bytes"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "At the CMTS, the total number of DOCSIS data bytes
           transported by this downstream channel.
           The number of data bytes is defined as the total number
           of bytes transported in DOCSIS payloads minus the number
           of stuff bytes transported in DOCSIS payloads.
           This is the 32-bit version of
           docsIfCmtsDownChnlCtrExtUsedBytes, included to provide
           back compatibility with SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsDownChannelCounterEntry 3 }
 docsIfCmtsDownChnlCtrExtTotalBytes OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "Bytes"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "At the CMTS, the total number of bytes in the Payload
           portion of MPEG Packets (i.e., not including MPEG header
           or pointer_field) transported by this downstream
           channel.
           This is the 64-bit version of
           docsIfCmtsDownChnlCtrTotalBytes and will not be
           accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsDownChannelCounterEntry 4 }
 docsIfCmtsDownChnlCtrExtUsedBytes OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "Bytes"
      MAX-ACCESS  read-only

Raftus & Cardona Standards Track [Page 100] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      STATUS      current
      DESCRIPTION
          "At the CMTS, the total number of DOCSIS data bytes
           transported by this downstream channel.  The number
           of data bytes is defined as the total number of bytes
           transported in DOCSIS payloads minus the number of
           stuff bytes transported in DOCSIS payloads.
           This is the 64-bit version of
           docsIfCmtsDownChnlCtrUsedBytes and will not be accessible
           to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsDownChannelCounterEntry 5 }
  1. - The following table provides operators with input data appropriate
  2. - for calculating upstream channel utilization, and for determining
  3. - the traffic characteristics of upstream channels. Operators may
  4. - use the docsIfCmtsChannelUtilizationTable or perform their own
  5. - polling of the docsIfCmtsUpChannelCounterTable objects for
  6. - utilization determination.
  7. - The first four 32 and 64 objects in this table are mandatory.
  8. - Vendors may choose to implement the remaining optional objects to
  9. - provide operators with finer characterization of upstream channel
  10. - traffic patterns. The 32-bit counter objects are included to
  11. - provide backward compatibility with SNMPv1 managers, which cannot
  12. - access 64-bit counter objects.
 docsIfCmtsUpChannelCounterTable OBJECT-TYPE
      SYNTAX      SEQUENCE OF DocsIfCmtsUpChannelCounterEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "This table is implemented at the CMTS to provide upstream
           channel statistics appropriate for channel utilization
           calculations."
      ::= { docsIfCmtsObjects 11 }
 docsIfCmtsUpChannelCounterEntry OBJECT-TYPE
      SYNTAX      DocsIfCmtsUpChannelCounterEntry
      MAX-ACCESS  not-accessible
      STATUS      current
      DESCRIPTION
          "List of traffic statistics for a single upstream channel.
           For DOCSIS 2.0 CMTSs, an entry in this table
           exists for each ifEntry with an ifType of
           docsCableUpstreamChannel (205).

Raftus & Cardona Standards Track [Page 101] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           For DOCSIS 1.x CMTSs, an entry in this table
           exists for each ifEntry with an ifType of
           docsCableUpstream (129)."
      INDEX { ifIndex }
      ::= { docsIfCmtsUpChannelCounterTable 1 }
 DocsIfCmtsUpChannelCounterEntry ::= SEQUENCE {
          docsIfCmtsUpChnlCtrId                          Integer32,
          docsIfCmtsUpChnlCtrTotalMslots                 Counter32,
          docsIfCmtsUpChnlCtrUcastGrantedMslots          Counter32,
          docsIfCmtsUpChnlCtrTotalCntnMslots             Counter32,
          docsIfCmtsUpChnlCtrUsedCntnMslots              Counter32,
          docsIfCmtsUpChnlCtrExtTotalMslots              Counter64,
          docsIfCmtsUpChnlCtrExtUcastGrantedMslots       Counter64,
          docsIfCmtsUpChnlCtrExtTotalCntnMslots          Counter64,
          docsIfCmtsUpChnlCtrExtUsedCntnMslots           Counter64,
          docsIfCmtsUpChnlCtrCollCntnMslots              Counter32,
          docsIfCmtsUpChnlCtrTotalCntnReqMslots          Counter32,
          docsIfCmtsUpChnlCtrUsedCntnReqMslots           Counter32,
          docsIfCmtsUpChnlCtrCollCntnReqMslots           Counter32,
          docsIfCmtsUpChnlCtrTotalCntnReqDataMslots      Counter32,
          docsIfCmtsUpChnlCtrUsedCntnReqDataMslots       Counter32,
          docsIfCmtsUpChnlCtrCollCntnReqDataMslots       Counter32,
          docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots    Counter32,
          docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots     Counter32,
          docsIfCmtsUpChnlCtrCollCntnInitMaintMslots     Counter32,
          docsIfCmtsUpChnlCtrExtCollCntnMslots           Counter64,
          docsIfCmtsUpChnlCtrExtTotalCntnReqMslots       Counter64,
          docsIfCmtsUpChnlCtrExtUsedCntnReqMslots        Counter64,
          docsIfCmtsUpChnlCtrExtCollCntnReqMslots        Counter64,
          docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots   Counter64,
          docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots    Counter64,
          docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots    Counter64,
          docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots Counter64,
          docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots  Counter64,
          docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots  Counter64
      }
 docsIfCmtsUpChnlCtrId OBJECT-TYPE
      SYNTAX      Integer32 (0..255)
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "The CMTS identification of the upstream channel."
      ::= { docsIfCmtsUpChannelCounterEntry 1 }
 docsIfCmtsUpChnlCtrTotalMslots OBJECT-TYPE
      SYNTAX      Counter32

Raftus & Cardona Standards Track [Page 102] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of all mini-slots
           defined for this upstream logical channel.  This count
           includes all IUCs and SIDs, even those allocated to the
           NULL SID for a 2.0 logical channel that is inactive.  This
           is the 32-bit version of docsIfCmtsUpChnlCtrExtTotalMslots
           and is included for back compatibility with SNMPv1
           managers.  Support for this object is mandatory.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 2 }
 docsIfCmtsUpChnlCtrUcastGrantedMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of unicast
           granted mini-slots on the upstream logical channel,
           regardless of burst type.  Unicast granted mini-slots are
           those in which the CMTS assigned bandwidth to any unicast
           SID on the logical channel.  However, this object does not
           include minis-lots for reserved IUCs, or grants to SIDs
           designated as meaning 'no CM'.  This is the 32-bit version
           of docsIfCmtsUpChnlCtrExtUcastGrantedMslots, and is
           included for back compatibility with SNMPv1 managers.
           Support for this object is mandatory.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 3 }
 docsIfCmtsUpChnlCtrTotalCntnMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           mini-slots defined for this upstream logical channel.  This
           count includes all mini-slots assigned to a broadcast or

Raftus & Cardona Standards Track [Page 103] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           multicast SID on the logical channel.  This is the 32-bit
           version of docsIfCmtsUpChnlCtrExtTotalCntnMslots, and is
           included for back compatibility with SNMPv1 managers.
           Support for this object is mandatory.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 4 }
 docsIfCmtsUpChnlCtrUsedCntnMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           mini-slots utilized on the upstream logical channel.  For
           contention regions, utilized mini-slots are those in which
           the CMTS correctly received an upstream burst from any CM
           on the upstream logical channel.  This is the 32-bit
           version of docsIfCmtsUpChnlCtrExtUsedCntnMslots and is
           included for back compatibility with SNMPv1 managers.
           Support for this object is mandatory.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 5 }
 docsIfCmtsUpChnlCtrExtTotalMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of all mini-slots
           defined for this upstream logical channel.  This count
           includes all IUCs and SIDs, even those allocated to the
           NULL SID for a 2.0 logical channel that is inactive.  This
           is the 64-bit version of docsIfCmtsUpChnlCtrTotalMslots
           and will not be accessible to SNMPv1 managers.
           Support for this object is mandatory.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 6 }

Raftus & Cardona Standards Track [Page 104] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 docsIfCmtsUpChnlCtrExtUcastGrantedMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of unicast
           granted mini-slots on the upstream logical channel,
           regardless of burst type.  Unicast granted mini-slots are
           those in which the CMTS assigned bandwidth to any unicast
           SID on the logical channel.  However, this object does not
           include mini-slots for reserved IUCs, or grants to SIDs
           designated as meaning 'no CM'.  This is the 64-bit version
           of docsIfCmtsUpChnlCtrUcastGrantedMslots and will not be
           accessible to SNMPv1 managers.
           Support for this object is mandatory.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 7 }
 docsIfCmtsUpChnlCtrExtTotalCntnMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           mini-slots defined for this upstream logical channel.  This
           count includes all mini-slots assigned to a broadcast or
           multicast SID on the logical channel.  This is the 64-bit
           version of docsIfCmtsUpChnlCtrTotalCntnMslots and will
           not be accessible to SNMPv1 managers.
           Support for this object is mandatory.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 8 }
 docsIfCmtsUpChnlCtrExtUsedCntnMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention

Raftus & Cardona Standards Track [Page 105] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           mini-slots utilized on the upstream logical channel.  For
           contention regions, utilized mini-slots are those in which
           the CMTS correctly received an upstream burst from any CM
           on the upstream logical channel.  This is the 64-bit
           version of docsIfCmtsUpChnlCtrUsedCntnMslots and will not
           be accessible to SNMPv1 managers.
           Support for this object is mandatory.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 9 }
 docsIfCmtsUpChnlCtrCollCntnMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           mini-slots subjected to collisions on the upstream logical
           channel.  For contention regions, these are the mini-slots
           applicable to bursts that the CMTS detected but could not
           correctly receive.  This is the 32-bit version of
           docsIfCmtsUpChnlCtrExtCollCntnMslots and is included for
           back compatibility with SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 10 }
 docsIfCmtsUpChnlCtrTotalCntnReqMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request mini-slots defined for this upstream logical
           channel.  This count includes all mini-slots for IUC1
           assigned to a broadcast or multicast SID on the logical
           channel.  This is the 32-bit version of
           docsIfCmtsUpChnlCtrExtTotalCntnReqMslots and is included
           for back compatibility with SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of

Raftus & Cardona Standards Track [Page 106] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 11 }
 docsIfCmtsUpChnlCtrUsedCntnReqMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request mini-slots utilized on this upstream logical
           channel.  This count includes all contention mini-slots for
           IUC1 applicable to bursts that the CMTS correctly
           received.  This is the 32-bit version of
           docsIfCmtsUpChnlCtrExtUsedCntnReqMslots and is included
           for back compatibility with SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 12 }
 docsIfCmtsUpChnlCtrCollCntnReqMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request mini-slots subjected to collisions on this upstream
           logical channel.  This includes all contention mini-slots
           for IUC1 applicable to bursts that the CMTS detected but
           could not correctly receive.  This is the 32-bit version of
           docsIfCmtsUpChnlCtrExtCollCntnReqMslots and is included
           for back compatibility with SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 13 }
 docsIfCmtsUpChnlCtrTotalCntnReqDataMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention

Raftus & Cardona Standards Track [Page 107] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           request data mini-slots defined for this upstream logical
           channel.  This count includes all mini-slots for IUC2
           assigned to a broadcast or multicast SID on the logical
           channel.  This is the 32-bit version of
           docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots and is
           included for back compatibility with SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 14 }
 docsIfCmtsUpChnlCtrUsedCntnReqDataMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
 MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request data mini-slots utilized on this upstream logical
           channel.  This includes all contention mini-slots for IUC2
           applicable to bursts that the CMTS correctly received.
           This is the 32-bit version of
           docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots and is
           included for back compatibility with SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 15 }
 docsIfCmtsUpChnlCtrCollCntnReqDataMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request data mini-slots subjected to collisions on this
           upstream logical channel.  This includes all contention
           mini-slots for IUC2 applicable to bursts that the CMTS
           detected, but could not correctly receive.  This is the
           32-bit version of
           docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots and is
           included for back compatibility with SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of

Raftus & Cardona Standards Track [Page 108] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 16 }
 docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           initial maintenance mini-slots defined for this upstream
           logical channel.  This includes all mini-slots for IUC3
           assigned to a broadcast or multicast SID on the logical
           channel.  This is the 32-bit version of
           docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots
           and is included for back compatibility with SNMPv1
           managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 17 }
 docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots OBJECT-TYPE
      SYNTAX      Counter32
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           initial maintenance mini-slots utilized on this upstream
           logical channel.  This includes all contention mini-slots
           for IUC3 applicable to bursts that the CMTS correctly
           received.  This is the 32-bit version of
           docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots
           and is included for back compatibility with SNMPv1
           managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 18 }
 docsIfCmtsUpChnlCtrCollCntnInitMaintMslots OBJECT-TYPE
      SYNTAX      Counter32
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION

Raftus & Cardona Standards Track [Page 109] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          "Current count, from CMTS initialization, of contention
           initial maintenance mini-slots subjected to collisions on
           this upstream logical channel.  This includes all
           contention mini-slots for IUC3 applicable to bursts that
           the CMTS detected, but could not correctly receive.
           This is the 32-bit version of
           docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots
           and is included for back compatibility with SNMPv1
           managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 19 }
 docsIfCmtsUpChnlCtrExtCollCntnMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of collision
           contention mini-slots on the upstream logical channel.
           For contention regions, these are the mini-slots applicable
           to bursts that the CMTS detected, but could not correctly
           receive.  This is the 64-bit version of
           docsIfCmtsUpChnlCtrCollCntnMslots and will not be
           accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 20 }
 docsIfCmtsUpChnlCtrExtTotalCntnReqMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request mini-slots defined for this upstream logical
           channel.  This count includes all mini-slots for IUC1
           assigned to a broadcast or multicast SID on the logical
           channel.  This is the 64-bit version of
           docsIfCmtsUpChnlCtrTotalCntnReqMslots and will not be
           accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur

Raftus & Cardona Standards Track [Page 110] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 21 }
 docsIfCmtsUpChnlCtrExtUsedCntnReqMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request mini-slots utilized on this upstream logical
           channel.  This count includes all contention mini-slots for
           IUC1 applicable to bursts that the CMTS correctly
           received.  This is the 64-bit version of
           docsIfCmtsUpChnlCtrUsedCntnReqMslots and will not be
           accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 22 }
 docsIfCmtsUpChnlCtrExtCollCntnReqMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request mini-slots subjected to collisions on this upstream
           logical channel.  This includes all contention mini-slots
           for IUC1 applicable to bursts that the CMTS detected,
           but could not correctly receive.  This is the 64-bit
           version of docsIfCmtsUpChnlCtrCollCntnReqMslots and will
           not be accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 23 }
 docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current

Raftus & Cardona Standards Track [Page 111] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request data mini-slots defined for this upstream logical
           channel.  This count includes all mini-slots for IUC2
           assigned to a broadcast or multicast SID on the logical
           channel.  This is the 64-bit version of
           docsIfCmtsUpChnlCtrTotalCntnReqDataMslots and will not be
           accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 24 }
 docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request data mini-slots utilized on this upstream logical
           channel.  This includes all contention mini-slots for IUC2
           applicable to bursts that the CMTS correctly received.
           This is the 64-bit version of
           docsIfCmtsUpChnlCtrUsedCntnReqDataMslots and will not be
           accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 25 }
 docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           request data mini-slots subjected to collisions on this
           upstream logical channel.  This includes all contention
           mini-slots for IUC2 applicable to bursts that the CMTS
           detected, but could not correctly receive.  This is the
           64-bit version of
           docsIfCmtsUpChnlCtrCollCntnReqDataMslots
           and will not be accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur

Raftus & Cardona Standards Track [Page 112] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 26 }
 docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of initial
           maintenance mini-slots defined for this upstream logical
           channel.  This count includes all mini-slots for IUC3
           assigned to a broadcast or multicast SID on the logical
           channel.  This is the 64-bit version of
           docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots
           and will not be accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 27 }
 docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current
      DESCRIPTION
          "Current count, from CMTS initialization, of initial
           maintenance mini-slots utilized on this upstream logical
           channel.  This includes all contention mini-slots for IUC3
           applicable to bursts that the CMTS correctly received.
           This is the 64-bit version of
           docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots
           and will not be accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 28 }
 docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots OBJECT-TYPE
      SYNTAX      Counter64
      UNITS       "mini-slots"
      MAX-ACCESS  read-only
      STATUS      current

Raftus & Cardona Standards Track [Page 113] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      DESCRIPTION
          "Current count, from CMTS initialization, of contention
           initial maintenance mini-slots subjected to collisions on
           this upstream logical channel.  This includes all
           contention mini-slots for IUC3 applicable to bursts that
           the CMTS detected, but could not correctly receive.
           This is the 64-bit version of
           docsIfCmtsUpChnlCtrCollCntnInitMaintMslots and will not
           be accessible to SNMPv1 managers.
           Discontinuities in the value of this counter can occur
           at reinitialization of the managed system, and at other
           times as indicated by the value of
           ifCounterDiscontinuityTime for the associated ifIndex."
      ::= { docsIfCmtsUpChannelCounterEntry 29 }
  1. -
  2. - notification group is for future extension.
  3. -
 docsIfNotification OBJECT IDENTIFIER     ::= { docsIfMib 2 }
  1. -
  2. - MIB Compliance statements.
  3. -
  1. -
  2. - Conformance definitions
  3. -
 docsIfConformance  OBJECT IDENTIFIER     ::= { docsIfMib 3 }
 docsIfCompliances  OBJECT IDENTIFIER     ::= { docsIfConformance 1 }
 docsIfGroups       OBJECT IDENTIFIER     ::= { docsIfConformance 2 }
 docsIfBasicCompliance MODULE-COMPLIANCE
      STATUS      deprecated
      DESCRIPTION
          "The compliance statement for devices that implement
           DOCSIS 1.x compliant Radio Frequency Interfaces."
 MODULE  -- docsIfMib
  1. - unconditionally mandatory groups

MANDATORY-GROUPS {

      docsIfBasicGroup
      }
  1. - conditionally mandatory group

GROUP docsIfCmGroup

Raftus & Cardona Standards Track [Page 114] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      DESCRIPTION
          "This group is implemented only in cable modems, not in
           cable modem termination systems."
  1. - conditionally mandatory group

GROUP docsIfCmtsGroup

      DESCRIPTION
          "This group is implemented only in cable modem termination
           systems, not in cable modems."
 OBJECT  docsIfDownChannelFrequency
      WRITE-SYNTAX Integer32 (54000000..860000000)
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems.  The values above are
           appropriate for a cable plant using a Sub-Split channel
           plan.  If DOCSIS is extended to cover other types of
           channel plans (and frequency allocations), this object
           will be modified accordingly."
 OBJECT  docsIfDownChannelWidth
      WRITE-SYNTAX Integer32 (6000000)
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is important to implement this object as read-only.
           In cable modems, this object is always implemented as
           read-only.  The above value is appropriate for cable
           plants running under NTSC (National Television
           Standards Committee) standards.  If DOCSIS is extended to
           work with other standards (e.g., European standards), this
           object will be modified accordingly."
 OBJECT  docsIfDownChannelModulation
      WRITE-SYNTAX INTEGER {
                             qam64 (3),
                             qam256 (4)
                           }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfDownChannelInterleave
      WRITE-SYNTAX INTEGER {
                  taps8Increment16(3),
                  taps16Increment8(4),
                  taps32Increment4(5),

Raftus & Cardona Standards Track [Page 115] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

                  taps64Increment2(6),
                  taps128Increment1(7)
                   }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfDownChannelPower
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelFrequency
      WRITE-SYNTAX Integer32 (5000000..42000000)
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems.  The values above are
           appropriate for a cable plant using a Sub-Split channel
           plan.  If DOCSIS is extended to cover other types of
           channel plans (and frequency allocations), this object
           will be modified accordingly."
 OBJECT  docsIfUpChannelWidth
      WRITE-SYNTAX Integer32 (200000..3200000)
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems.  The above value is appropriate
           for cable plants running under NTSC (National Television
           Standards Committee) standards.  If DOCSIS is extended to
           work with other standards (e.g., European standards), this
           object will be modified accordingly."
 OBJECT  docsIfUpChannelModulationProfile
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelSlotSize
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."

Raftus & Cardona Standards Track [Page 116] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 OBJECT  docsIfUpChannelRangingBackoffStart
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelRangingBackoffEnd
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelTxBackoffStart
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelTxBackoffEnd
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfQosProfPriority
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfMaxUpBandwidth
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfGuarUpBandwidth
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfMaxDownBandwidth
      MIN-ACCESS  read-only
      DESCRIPTION

Raftus & Cardona Standards Track [Page 117] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfMaxTxBurst
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfBaselinePrivacy
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfStatus
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfCmtsServiceAdminStatus
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsSyncInterval
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsUcdInterval
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsInsertInterval
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsInvitedRangingAttempts
      MIN-ACCESS  read-only
      DESCRIPTION

Raftus & Cardona Standards Track [Page 118] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsQosProfilePermissions
      WRITE-SYNTAX     BITS {
          createByManagement(0),
          updateByManagement(1)
         }
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT docsIfCmtsModType
      WRITE-SYNTAX INTEGER {
                      qpsk (2),
                      qam16 (3)
                       }
      DESCRIPTION
          "A management station MAY only set 16QAM or QPSK modulation,
           but others might be possible, based on device
           configuration."
 OBJECT  docsIfCmtsModPreambleLen
      SYNTAX Integer32 (0..1024)
      DESCRIPTION
          "The range of the values for this MODULE-COMPLIANCE
           is 0..1024."
 OBJECT  docsIfCmtsModFECErrorCorrection
         SYNTAX Integer32 (0..10)
         DESCRIPTION
             "The range of the values for this MODULE-COMPLIANCE
              is 0..10."
      ::= { docsIfCompliances 1 }
 docsIfBasicComplianceV2 MODULE-COMPLIANCE
      STATUS      current
      DESCRIPTION
          "The compliance statement for devices that implement
           DOCSIS 2.0 Radio Frequency Interfaces."
 MODULE  -- docsIfMib
  1. - unconditionally mandatory groups

MANDATORY-GROUPS {

      docsIfBasicGroupV2
      }

Raftus & Cardona Standards Track [Page 119] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

  1. - conditionally mandatory group

GROUP docsIfCmGroupV2

      DESCRIPTION
          "This group is implemented only in cable modems, not in
           cable modem termination systems."
  1. - conditionally mandatory group

GROUP docsIfCmtsGroupV2

      DESCRIPTION
          "This group is implemented only in cable modem termination
           systems, not in cable modems."
 OBJECT  docsIfDownChannelFrequency
      WRITE-SYNTAX Integer32 (47000000..862000000)
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems.
           A range of 54MHz to 860MHz is appropriate for a cable
           plant using a North American Sub-Split channel plan.
           The spectrum range has been expanded to accommodate
           a lower edge of 47MHz and an upper edge of 862MHz
           for some European channel plans.
           If DOCSIS is extended to cover other types of channel
           plans (and frequency allocations), this object will be
           modified accordingly."
 OBJECT  docsIfDownChannelWidth
      WRITE-SYNTAX Integer32 (6000000 | 8000000)
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is important to implement this object as read-only.
           In cable modems, this object is always implemented as
           read-only.  The value of 6 MHz is appropriate for cable
           plants running under NTSC (National Television
           Standards Committee) standards.  The value of 8 MHz is
           appropriate for cable plants running under ETSI
           standards.  For other regional standards, this
           object will be modified accordingly."
 OBJECT  docsIfDownChannelModulation
      WRITE-SYNTAX INTEGER {
                             qam64 (3),
                             qam256 (4)
                           }
      MIN-ACCESS  read-only
      DESCRIPTION

Raftus & Cardona Standards Track [Page 120] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfDownChannelInterleave
      WRITE-SYNTAX INTEGER {
                  taps8Increment16(3),
                  taps16Increment8(4),
                  taps32Increment4(5),
                  taps64Increment2(6),
                  taps128Increment1(7),
                  taps12increment17(8)
                   }
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfDownChannelPower
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-write in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelFrequency
      WRITE-SYNTAX Integer32 (5000000..65000000)
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems.
           A range of 5MHz to 42MHz is appropriate for a cable
           plant using a North American Sub-Split channel plan.
           The spectrum range has been expanded to accommodate
           an upper edge of 65MHz for some European channel plans.
           If DOCSIS is extended to cover other types of channel
           plans (and frequency allocations), this object will
           be modified accordingly."
 OBJECT  docsIfUpChannelWidth
      WRITE-SYNTAX Integer32 (200000..6400000)
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems,
           read-only in cable modems.  The above value is appropriate
           for cable plants running under NTSC (National Television
           Standards Committee) standards.  If DOCSIS is extended to
           work with other standards (e.g., European standards), this
           object will be modified accordingly."

Raftus & Cardona Standards Track [Page 121] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 OBJECT  docsIfUpChannelModulationProfile
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelSlotSize
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfUpChannelRangingBackoffStart
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelRangingBackoffEnd
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelTxBackoffStart
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelTxBackoffEnd
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelScdmaActiveCodes
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems.
           The number of active codes when SCDMA is in use MUST range
           from 64 to 128 and MUST be a non-Prime value.
           Providing this range allows for the following features
           and capabilities:
              1) Power management in S-CDMA spreader-on frames
                 (with a 3 dB spread).

Raftus & Cardona Standards Track [Page 122] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

              2) Avoidance of code 0.
              3) Flexible mini-slot sizes with and without the use of
                 code 0."
 OBJECT  docsIfUpChannelScdmaCodesPerSlot
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelScdmaFrameSize
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelScdmaHoppingSeed
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelCloneFrom
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelUpdate
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."
 OBJECT  docsIfUpChannelStatus
         MIN-ACCESS  read-only
         DESCRIPTION
             "Read-create in Cable Modem Termination Systems;
              read-only in Cable Modems.
              Entries associated to physical interfaces only support
              the read-only value 'active'."
 OBJECT  docsIfUpChannelPreEqEnable
      MIN-ACCESS  read-only
      DESCRIPTION
          "Read-create in cable modem termination systems;
           read-only in cable modems."

Raftus & Cardona Standards Track [Page 123] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 OBJECT  docsIfQosProfPriority
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfMaxUpBandwidth
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfGuarUpBandwidth
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfMaxDownBandwidth
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfBaselinePrivacy
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfStatus
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."
 OBJECT  docsIfQosProfMaxTransmitBurst
      MIN-ACCESS  read-only
      DESCRIPTION
          "This object is always read-only in cable modems.
           It is compliant to implement this object as read-only
           in cable modem termination systems."

Raftus & Cardona Standards Track [Page 124] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 OBJECT  docsIfCmRangingTimeout
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT docsIfCmStatusModulationType
     SYNTAX          INTEGER {
         unknown(0),
         tdma(1),
         atdma(2),
         scdma(3)
     }
      DESCRIPTION
          "CM does not use both modulation burst profiles of a
           'tdmAndAtdma' ChannelType; therefore, 'tdmAndAtdma'is
           not supported."
 OBJECT  docsIfCmtsServiceAdminStatus
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsSyncInterval
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsUcdInterval
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsInsertInterval
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsInvitedRangingAttempts
      MIN-ACCESS  read-only
      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT  docsIfCmtsQosProfilePermissions
      WRITE-SYNTAX     BITS {
          createByManagement(0),
          updateByManagement(1)
         }
      MIN-ACCESS  read-only

Raftus & Cardona Standards Track [Page 125] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      DESCRIPTION
          "It is compliant to implement this object as read-only."
 OBJECT docsIfCmtsModType
      WRITE-SYNTAX      INTEGER {
          qpsk(2),
          qam16(3),
          qam64(6)
      }
      DESCRIPTION
          "A management station MAY only set 64QAM, 16QAM, or QPSK
           modulation for Time or Code division Multiple Access,
           but others might be possible based on device
           configuration."
 OBJECT docsIfCmtsCmStatusModulationType
     SYNTAX          INTEGER {
         unknown(0),
         tdma(1),
         atdma(2),
         scdma(3)
     }
      DESCRIPTION
          "CM does not use both modulation burst profiles of a
           'tdmAndAtdma' ChannelType; therefore, 'tdmAndAtdma'is
           not supported."
      ::= { docsIfCompliances 2 }
 docsIfBasicGroup OBJECT-GROUP
      OBJECTS {
          docsIfDownChannelId,
          docsIfDownChannelFrequency,
          docsIfDownChannelWidth,
          docsIfDownChannelModulation,
          docsIfDownChannelInterleave,
          docsIfDownChannelPower,
          docsIfUpChannelId,
          docsIfUpChannelFrequency,
          docsIfUpChannelWidth,
          docsIfUpChannelModulationProfile,
          docsIfUpChannelSlotSize,
          docsIfUpChannelTxTimingOffset,
          docsIfUpChannelRangingBackoffStart,
          docsIfUpChannelRangingBackoffEnd,
          docsIfUpChannelTxBackoffStart,
          docsIfUpChannelTxBackoffEnd,
          docsIfQosProfPriority,

Raftus & Cardona Standards Track [Page 126] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          docsIfQosProfMaxUpBandwidth,
          docsIfQosProfGuarUpBandwidth,
          docsIfQosProfMaxDownBandwidth,
          docsIfQosProfMaxTxBurst,
          docsIfQosProfBaselinePrivacy,
          docsIfQosProfStatus,
          docsIfSigQIncludesContention,
          docsIfSigQUnerroreds,
          docsIfSigQCorrecteds,
          docsIfSigQUncorrectables,
          docsIfSigQSignalNoise,
          docsIfSigQMicroreflections,
          docsIfSigQEqualizationData
      }
      STATUS      deprecated
      DESCRIPTION
          "Group of objects implemented in both cable modems and
           cable modem termination systems."
      ::= { docsIfGroups 1 }
 docsIfCmGroup OBJECT-GROUP
      OBJECTS {
          docsIfCmCmtsAddress,
          docsIfCmCapabilities,
          docsIfCmRangingTimeout,
          docsIfCmStatusValue,
          docsIfCmStatusCode,
          docsIfCmStatusTxPower,
          docsIfCmStatusResets,
          docsIfCmStatusLostSyncs,
          docsIfCmStatusInvalidMaps,
          docsIfCmStatusInvalidUcds,
          docsIfCmStatusInvalidRangingResponses,
          docsIfCmStatusInvalidRegistrationResponses,
          docsIfCmStatusT1Timeouts,
          docsIfCmStatusT2Timeouts,
          docsIfCmStatusT3Timeouts,
          docsIfCmStatusT4Timeouts,
          docsIfCmStatusRangingAborteds,
          docsIfCmServiceQosProfile,
          docsIfCmServiceTxSlotsImmed,
          docsIfCmServiceTxSlotsDed,
          docsIfCmServiceTxRetries,
          docsIfCmServiceTxExceededs,
          docsIfCmServiceRqRetries,
          docsIfCmServiceRqExceededs
      }
      STATUS      deprecated

Raftus & Cardona Standards Track [Page 127] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

      DESCRIPTION
          "Group of objects implemented in cable modems."
      ::= { docsIfGroups 2 }
 docsIfCmtsGroup OBJECT-GROUP
      OBJECTS {
          docsIfCmtsCapabilities,
          docsIfCmtsSyncInterval,
          docsIfCmtsUcdInterval,
          docsIfCmtsMaxServiceIds,
          docsIfCmtsInvitedRangingAttempts,
          docsIfCmtsInsertInterval,
          docsIfCmtsStatusInvalidRangeReqs,
          docsIfCmtsStatusRangingAborteds,
          docsIfCmtsStatusInvalidRegReqs,
          docsIfCmtsStatusFailedRegReqs,
          docsIfCmtsStatusInvalidDataReqs,
          docsIfCmtsStatusT5Timeouts,
          docsIfCmtsCmStatusMacAddress,
          docsIfCmtsCmStatusIpAddress,
          docsIfCmtsCmStatusDownChannelIfIndex,
          docsIfCmtsCmStatusUpChannelIfIndex,
          docsIfCmtsCmStatusRxPower,
          docsIfCmtsCmStatusTimingOffset,
          docsIfCmtsCmStatusEqualizationData,
          docsIfCmtsCmStatusValue,
          docsIfCmtsCmStatusUnerroreds,
          docsIfCmtsCmStatusCorrecteds,
          docsIfCmtsCmStatusUncorrectables,
          docsIfCmtsCmStatusSignalNoise,
          docsIfCmtsCmStatusMicroreflections,
          docsIfCmtsServiceCmStatusIndex,
          docsIfCmtsServiceAdminStatus,
          docsIfCmtsServiceQosProfile,
          docsIfCmtsServiceCreateTime,
          docsIfCmtsServiceInOctets,
          docsIfCmtsServiceInPackets,
          docsIfCmtsModType,
          docsIfCmtsModControl,
          docsIfCmtsModPreambleLen,
          docsIfCmtsModDifferentialEncoding,
          docsIfCmtsModFECErrorCorrection,
          docsIfCmtsModFECCodewordLength,
          docsIfCmtsModScramblerSeed,
          docsIfCmtsModMaxBurstSize,
          docsIfCmtsModGuardTimeSize,
          docsIfCmtsModLastCodewordShortened,
          docsIfCmtsModScrambler,

Raftus & Cardona Standards Track [Page 128] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          docsIfCmtsQosProfilePermissions,
          docsIfCmtsCmPtr
      }
      STATUS      deprecated
      DESCRIPTION
          "Group of objects implemented in Cable Modem Termination
           Systems."
      ::= { docsIfGroups 3 }
  1. - obsolete group
  2. - RFC 2670 already had a obsolete group, even though RFC2670
  3. - was the first version of this MIB Module.
 docsIfObsoleteGroup OBJECT-GROUP
      OBJECTS {
          docsIfCmRangingRespTimeout,
          docsIfCmtsInsertionInterval
      }
      STATUS      obsolete
      DESCRIPTION
          "Group of objects obsoleted."
      ::= { docsIfGroups 4 }
 docsIfBasicGroupV2 OBJECT-GROUP
      OBJECTS {
          docsIfDownChannelId,
          docsIfDownChannelFrequency,
          docsIfDownChannelWidth,
          docsIfDownChannelModulation,
          docsIfDownChannelInterleave,
          docsIfDownChannelPower,
          docsIfDownChannelAnnex,
          docsIfUpChannelId,
          docsIfUpChannelFrequency,
          docsIfUpChannelWidth,
          docsIfUpChannelModulationProfile,
          docsIfUpChannelSlotSize,
          docsIfUpChannelTxTimingOffset,
          docsIfUpChannelRangingBackoffStart,
          docsIfUpChannelRangingBackoffEnd,
          docsIfUpChannelTxBackoffStart,
          docsIfUpChannelTxBackoffEnd,
          docsIfUpChannelScdmaActiveCodes,
          docsIfUpChannelScdmaCodesPerSlot,
          docsIfUpChannelScdmaFrameSize,
          docsIfUpChannelScdmaHoppingSeed,
          docsIfUpChannelType,
          docsIfUpChannelCloneFrom,

Raftus & Cardona Standards Track [Page 129] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          docsIfUpChannelUpdate,
          docsIfUpChannelStatus,
          docsIfUpChannelPreEqEnable,
          docsIfQosProfPriority,
          docsIfQosProfMaxUpBandwidth,
          docsIfQosProfGuarUpBandwidth,
          docsIfQosProfMaxDownBandwidth,
          docsIfQosProfBaselinePrivacy,
          docsIfQosProfStatus,
          docsIfQosProfMaxTransmitBurst,
          docsIfSigQIncludesContention,
          docsIfSigQUnerroreds,
          docsIfSigQCorrecteds,
          docsIfSigQUncorrectables,
          docsIfSigQSignalNoise,
          docsIfSigQMicroreflections,
          docsIfSigQExtUnerroreds,
          docsIfSigQExtCorrecteds,
          docsIfSigQExtUncorrectables,
          docsIfDocsisBaseCapability
      }
      STATUS      current
      DESCRIPTION
          "Group of objects implemented in both cable modems and
           cable modem termination systems."
      ::= { docsIfGroups 5 }
 docsIfCmGroupV2 OBJECT-GROUP
      OBJECTS {
          docsIfCmCmtsAddress,
          docsIfCmCapabilities,
          docsIfCmRangingTimeout,
          docsIfCmStatusValue,
          docsIfCmStatusCode,
          docsIfCmStatusTxPower,
          docsIfCmStatusResets,
          docsIfCmStatusLostSyncs,
          docsIfCmStatusInvalidMaps,
          docsIfCmStatusInvalidUcds,
          docsIfCmStatusInvalidRangingResponses,
          docsIfCmStatusInvalidRegistrationResponses,
          docsIfCmStatusT1Timeouts,
          docsIfCmStatusT2Timeouts,
          docsIfCmStatusT3Timeouts,
          docsIfCmStatusT4Timeouts,
          docsIfCmStatusRangingAborteds,
          docsIfCmStatusDocsisOperMode,
          docsIfCmStatusModulationType,

Raftus & Cardona Standards Track [Page 130] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          docsIfCmStatusEqualizationData,
          docsIfCmStatusUCCs,
          docsIfCmStatusUCCFails,
          docsIfCmServiceQosProfile,
          docsIfCmServiceTxSlotsImmed,
          docsIfCmServiceTxSlotsDed,
          docsIfCmServiceTxRetries,
          docsIfCmServiceTxExceededs,
          docsIfCmServiceRqRetries,
          docsIfCmServiceRqExceededs,
          docsIfCmServiceExtTxSlotsImmed,
          docsIfCmServiceExtTxSlotsDed,
          docsIfSigQEqualizationData
      }
      STATUS      current
      DESCRIPTION
          "Group of objects implemented in cable modems."
      ::= { docsIfGroups 6 }
 docsIfCmtsGroupV2 OBJECT-GROUP
      OBJECTS {
          docsIfCmtsCapabilities,
          docsIfCmtsSyncInterval,
          docsIfCmtsUcdInterval,
          docsIfCmtsMaxServiceIds,
          docsIfCmtsInvitedRangingAttempts,
          docsIfCmtsInsertInterval,
          docsIfCmtsMacStorageType,
          docsIfCmtsStatusInvalidRangeReqs,
          docsIfCmtsStatusRangingAborteds,
          docsIfCmtsStatusInvalidRegReqs,
          docsIfCmtsStatusFailedRegReqs,
          docsIfCmtsStatusInvalidDataReqs,
          docsIfCmtsStatusT5Timeouts,
          docsIfCmtsCmStatusMacAddress,
          docsIfCmtsCmStatusDownChannelIfIndex,
          docsIfCmtsCmStatusUpChannelIfIndex,
          docsIfCmtsCmStatusRxPower,
          docsIfCmtsCmStatusTimingOffset,
          docsIfCmtsCmStatusEqualizationData,
          docsIfCmtsCmStatusValue,
          docsIfCmtsCmStatusUnerroreds,
          docsIfCmtsCmStatusCorrecteds,
          docsIfCmtsCmStatusUncorrectables,
          docsIfCmtsCmStatusSignalNoise,
          docsIfCmtsCmStatusMicroreflections,
          docsIfCmtsCmStatusExtUnerroreds,
          docsIfCmtsCmStatusExtCorrecteds,

Raftus & Cardona Standards Track [Page 131] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          docsIfCmtsCmStatusExtUncorrectables,
          docsIfCmtsCmStatusDocsisRegMode,
          docsIfCmtsCmStatusModulationType,
          docsIfCmtsCmStatusInetAddressType,
          docsIfCmtsCmStatusInetAddress,
          docsIfCmtsCmStatusValueLastUpdate,
          docsIfCmtsCmStatusHighResolutionTimingOffset,
          docsIfCmtsServiceAdminStatus,
          docsIfCmtsServiceQosProfile,
          docsIfCmtsServiceCreateTime,
          docsIfCmtsServiceInOctets,
          docsIfCmtsServiceInPackets,
          docsIfCmtsServiceNewCmStatusIndex,
          docsIfCmtsModType,
          docsIfCmtsModControl,
          docsIfCmtsModPreambleLen,
          docsIfCmtsModDifferentialEncoding,
          docsIfCmtsModFECErrorCorrection,
          docsIfCmtsModFECCodewordLength,
          docsIfCmtsModScramblerSeed,
          docsIfCmtsModMaxBurstSize,
          docsIfCmtsModGuardTimeSize,
          docsIfCmtsModLastCodewordShortened,
          docsIfCmtsModScrambler,
          docsIfCmtsModByteInterleaverDepth,
          docsIfCmtsModByteInterleaverBlockSize,
          docsIfCmtsModPreambleType,
          docsIfCmtsModTcmErrorCorrectionOn,
          docsIfCmtsModScdmaInterleaverStepSize,
          docsIfCmtsModScdmaSpreaderEnable,
          docsIfCmtsModScdmaSubframeCodes,
          docsIfCmtsModChannelType,
          docsIfCmtsModStorageType,
          docsIfCmtsQosProfilePermissions,
          docsIfCmtsCmPtr,
          docsIfCmtsChannelUtilizationInterval,
          docsIfCmtsChannelUtUtilization,
          docsIfCmtsDownChnlCtrId,
          docsIfCmtsDownChnlCtrTotalBytes,
          docsIfCmtsDownChnlCtrUsedBytes,
          docsIfCmtsDownChnlCtrExtTotalBytes,
          docsIfCmtsDownChnlCtrExtUsedBytes,
          docsIfCmtsUpChnlCtrId,
          docsIfCmtsUpChnlCtrTotalMslots,
          docsIfCmtsUpChnlCtrUcastGrantedMslots,
          docsIfCmtsUpChnlCtrTotalCntnMslots,
          docsIfCmtsUpChnlCtrUsedCntnMslots,
          docsIfCmtsUpChnlCtrExtTotalMslots,

Raftus & Cardona Standards Track [Page 132] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

          docsIfCmtsUpChnlCtrExtUcastGrantedMslots,
          docsIfCmtsUpChnlCtrExtTotalCntnMslots,
          docsIfCmtsUpChnlCtrExtUsedCntnMslots,
          docsIfCmtsUpChnlCtrCollCntnMslots,
          docsIfCmtsUpChnlCtrTotalCntnReqMslots,
          docsIfCmtsUpChnlCtrUsedCntnReqMslots,
          docsIfCmtsUpChnlCtrCollCntnReqMslots,
          docsIfCmtsUpChnlCtrTotalCntnReqDataMslots,
          docsIfCmtsUpChnlCtrUsedCntnReqDataMslots,
          docsIfCmtsUpChnlCtrCollCntnReqDataMslots,
          docsIfCmtsUpChnlCtrTotalCntnInitMaintMslots,
          docsIfCmtsUpChnlCtrUsedCntnInitMaintMslots,
          docsIfCmtsUpChnlCtrCollCntnInitMaintMslots,
          docsIfCmtsUpChnlCtrExtCollCntnMslots,
          docsIfCmtsUpChnlCtrExtTotalCntnReqMslots,
          docsIfCmtsUpChnlCtrExtUsedCntnReqMslots,
          docsIfCmtsUpChnlCtrExtCollCntnReqMslots,
          docsIfCmtsUpChnlCtrExtTotalCntnReqDataMslots,
          docsIfCmtsUpChnlCtrExtUsedCntnReqDataMslots,
          docsIfCmtsUpChnlCtrExtCollCntnReqDataMslots,
          docsIfCmtsUpChnlCtrExtTotalCntnInitMaintMslots,
          docsIfCmtsUpChnlCtrExtUsedCntnInitMaintMslots,
          docsIfCmtsUpChnlCtrExtCollCntnInitMaintMslots,
          docsIfDownChannelStorageType,
          docsIfQosProfStorageType
      }
      STATUS      current
      DESCRIPTION
          "Group of objects implemented in Cable Modem Termination
           Systems."
      ::= { docsIfGroups 7 }
 END

Raftus & Cardona Standards Track [Page 133] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

5. Revision History

5.1. Scope

 The MIB module in this document has been developed to accommodate
 DOCSIS 2.0 devices and their system capabilities.  The MIB module is
 an update to RFC 2670 [RFC2670] with the additional incorporation of
 DOCSIS 2.0 [RFI2.0] and Euro-DOCSIS specification requirements
 [EN-300-429].

5.2. Extension

 We have maintained the MIB objects as defined in RFC 2670 [RFC2670].
 In some cases new MIB objects have been created with identical
 functionality but greater capacity (i.e., 32 to 64 bits).  In these
 situations, both the original 32 bit objects and the new 64 bit
 objects must be implemented.

6. Security Considerations

 This MIB module relates to a system that will provide metropolitan
 public internet access.  As such, improper manipulation of the MIB
 objects represented by this MIB module may result in denial of
 service to a large number of end-users.
 There are a number of management objects defined in this MIB that
 have a MAX-ACCESS clause of read-write or read-create.  Such objects
 may be considered sensitive or vulnerable in some network
 environments.  The support for SET operations in a non-secure
 environment without proper protection can have a negative effect on
 network operations.
 The CMTS is the controller of most of the parameters of the DOCSIS
 RFI Interface.  Therefore, write access to the CMTS MIB objects may
 compromise the end-user's services.
 In the CM case, the only read-write object of this MIB module is
 docsIfCmRangingTimeout, which if SET maliciously, may not constitute
 a critical factor of service degradation.
 The rest of the CM-required MIB objects in this MIB module are read-
 only, either by definition, or by compliance statements.
 The CMTS is the controller of most of the parameters of the DOCSIS
 RFI Interface.  Below are the CMTS MIB object's vulnerabilities:
 o  Objects in the docsIfBasicGroupv2, if SET maliciously, could
    result in a denial of service.  Particularly, SETs to objects in

Raftus & Cardona Standards Track [Page 134] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

    docsIfDownstreamChannelTable, docsIfUpstreamChannelTable,
    docsIfCmtsModulationTable, and docsIfQosProfileTable (the last one
    in conjunction with the MIB object
    docsIfCmtsQosProfilePermissions) can alter negatively the physical
    and link layer parameters of upstream and downstream channels.
 o  The Object docsIfCmtsServiceAdminStatus of the docsIfCmtsGroupv2
    group, when SET maliciously by an attacker to 'disabled' or
    'destroyed', will interrupt the service of the corresponding cable
    modem.
 Some of the readable objects in this MIB module (i.e., objects with a
 MAX-ACCESS other than not-accessible) may be considered sensitive or
 vulnerable in some network environments.  It is thus important to
 control even GET and/or NOTIFY access to these objects and possibly
 to even encrypt the values of these objects when sending them over
 the network via SNMP.  Below are some sensitivity considerations:
 o  Read access to the MIB objects in tables docsIfCmStatusTable (CM),
    docsIfSignalQualityTable (CM/CMTS) and in CMTS tables
    docsIfCmtsCmStatusTable, docsIfCmtsChannelUtilizationTable,
    docsIfCmtsDownChannelCounterTable, and
    docsIfCmtsUpChannelCounterTable, could reveal information about
    the cable modems' distribution among the upstream and downstream
    channels and their performance, which could be used to gain access
    to a different tiered service offer.  The table
    docsIfCmtsCmStatusTable also contains the MAC and IP addresses of
    the cable modems, which can be used for theft of service.
 SNMP versions prior to SNMPv3 did not include adequate security.
 Even if the network itself is secure (for example by using IPSec),
 even then, there is no control as to who on the secure network is
 allowed to access and GET/SET (read/change/create/delete) the objects
 in this MIB module.
 It is RECOMMENDED that implementers consider the security features as
 provided by the SNMPv3 framework (see [RFC3410], section 8),
 including full support for the SNMPv3 cryptographic mechanisms (for
 authentication and privacy).
 Further, deployment of SNMP versions prior to SNMPv3 is NOT
 RECOMMENDED.  Instead, it is RECOMMENDED to deploy SNMPv3 and to
 enable cryptographic security.  It is then a customer/operator
 responsibility to ensure that the SNMP entity giving access to an
 instance of this MIB module is properly configured to give access to
 the objects only to those principals (users) that have legitimate
 rights to indeed GET or SET (change/create/delete) them.

Raftus & Cardona Standards Track [Page 135] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

7. Management Interoperability of DOCSIS 1.0, 1.1, and 2.0

 The MIB module contained in this document updates RFC 2670 [RFC2670],
 primarily to handle the management requirements of the DOCSIS RF
 Interface of DOCSIS 2.0 [ITU-T_J.122].  RFC 2670 contains the DOCSIS
 RF Interface management requirements for DOCSIS 1.0 and DOCSIS 1.1.
 The management requirements of Class of Service (DOCSIS 1.0)
 pertaining to RFC 2670 are the same as this document update and are
 contained in the tables docsIfQosProfileTable, docsIfCmServiceTable,
 and docsIfCmtsServiceTable.
 DOCSIS 1.1 and DOCSIS 2.0 Quality of Service management requirements
 are defined in the DOCSIS management specifications [OSSI1.1] and
 [OSSI2.0], respectively.

8. References

8.1. Normative References

 [EN-300-429]  European Telecommunications Standard Institute, "ETSI
               Standard EN 300 429, Version 1.2.1: Digital Video
               Broadcasting (DVB), Framing structure, channel coding
               and modulation for cable systems", April 1998.
 [IANA]        Internet Assigned Numbers Authority, "Internet Assigned
               Numbers Authority", October 2005,
               <http://www.iana.org/assignments/ianaiftype-mib/>.
 [ITU-T_J.112] Telecommunication Standardization Sector of
               International Telecommunications Union, "Transmission
               Systems for Interactive Cable Television Services,
               Annex B.", March 2001, <http://www.itu.int/ITU-
               T/studygroups/com09/>.
 [ITU-T_J.122] Telecommunication Standardization Sector of
               International Telecommunications Union, "Second-
               Generation Transmission Systems for Interactive Cable
               Television Services.", December 2002,
               <http://www.itu.int/ITU-T/studygroups/com09/>.
 [ITU-T_J.83]  Telecommunication Standardization Sector of
               International Telecommunications Union, "ITU-T
               Recommendation J.83(4/97), Digital multi-programme
               systems for television sound and data services for
               cable distribution.", April 1997,
               <http://www.itu.int/ITU-T/studygroups/com09/>.

Raftus & Cardona Standards Track [Page 136] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 [RFC2119]     Bradner, S., "Key words for use in RFCs to Indicate
               Requirement Levels", BCP 14, RFC 2119, March 1997.
 [RFC2578]     McCloghrie, K., Perkins, D., and J. Schoenwaelder,
               "Structure of Management Information Version 2
               (SMIv2)", STD 58, RFC 2578, April 1999.
 [RFC2579]     McCloghrie, K., Perkins, D., and J. Schoenwaelder,
               "Textual Conventions for SMIv2", STD 58, RFC 2579,
               April 1999.
 [RFC2580]     McCloghrie, K., Perkins, D., and J. Schoenwaelder,
               "Conformance Statements for SMIv2", STD 58, RFC 2580,
               April 1999.
 [RFC2863]     McCloghrie, K. and F. Kastenholz, "The Interfaces Group
               MIB", RFC 2863, June 2000.
 [RFC4001]     Daniele, M., Haberman, B., Routhier, S., and J.
               Schoenwaelder, "Textual Conventions for Internet
               Network Addresses", RFC 4001, February 2005.
 [RFI1.1]      CableLabs, "Data-Over-Cable Service Interface
               Specifications: Radio Frequency Interface Specification
               SP-RFIv1.1-C01-050907", September 2005,
               <http://www.cablemodem.com/specifications/>.
 [RFI2.0]      CableLabs, "Data-Over-Cable Service Interface
               Specifications: Radio Frequency Interface Specification
               SP-RFIv2.0-I09-050812", August 2005,
               <http://www.cablemodem.com/specifications/>.

8.2. Informative References

 [BPI]         SCTE Data Standards Subcommittee, "Data-Over-Cable
               Service Interface Specifications: DOCSIS 1.0 Baseline
               Privacy Interface Specification SCTE 22-2 2002", 2002,
               <http://www.scte.org/standards/>.
 [BPIPLUS]     CableLabs, "Data-Over-Cable Service Interface
               Specifications: Baseline Privacy Plus Interface
               Specification SP-BPI+-I12-050812", August 2005,
               <http://www.cablemodem.com/specifications/>.
 [OSSI1.1]     CableLabs, "Data-Over-Cable Service Interface
               Specifications: Operations Support System Interface
               Specification SP-OSSIv1.1-C01-050907", September 2005,
               <http://www.cablemodem.com/specifications/>.

Raftus & Cardona Standards Track [Page 137] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

 [OSSI2.0]     CableLabs, "Data-Over-Cable Service Interface
               Specifications: Operations Support System Interface
               Specification SP-OSSIv2.0-I09-050812", September 2005,
               <http://www.cablemodem.com/specifications/>.
 [Proakis00]   McGraw-Hill, "Digital Communications, 4th Edition",
               2000.
 [RFC2670]     St. Johns, M., "Radio Frequency (RF) Interface
               Management Information Base for MCNS/DOCSIS compliant
               RF interfaces", RFC 2670, August 1999.
 [RFC3410]     Case, J., Mundy, R., Partain, D., and B. Stewart,
               "Introduction and Applicability Statements for
               Internet-Standard Management Framework", RFC 3410,
               December 2002.
 [RFI1.0]      SCTE Data Standards Subcommittee, "Data-Over-Cable
               Service Interface Specifications: DOCSIS 1.0 Radio
               Frequency Interface Specification SCTE 22-1 2002",
               2002, <http://www.scte.org/standards/>.

Authors' Addresses

 David Raftus
 ATI Technologies
 340 Terry Fox Drive, Suite 202
 Ottawa, Ontario
 Canada
 Phone: +1 613 592 1052 ext.222
 EMail: david.raftus@ati.com
 Eduardo Cardona
 Cable Television Laboratories, Inc.
 858 Coal Creek Circle
 Louisville, CO  80020
 USA
 Phone: +1 303 661 3375
 EMail: e.cardona@cablelabs.com

Raftus & Cardona Standards Track [Page 138] RFC 4546 DOCSIS 2.0 Radio Frequency (RFI) MIB June 2006

Full Copyright Statement

 Copyright (C) The Internet Society (2006).
 This document is subject to the rights, licenses and restrictions
 contained in BCP 78, and except as set forth therein, the authors
 retain all their rights.
 This document and the information contained herein are provided on an
 "AS IS" basis and THE CONTRIBUTOR, THE ORGANIZATION HE/SHE REPRESENTS
 OR IS SPONSORED BY (IF ANY), THE INTERNET SOCIETY AND THE INTERNET
 ENGINEERING TASK FORCE DISCLAIM ALL WARRANTIES, EXPRESS OR IMPLIED,
 INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE
 INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED
 WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Intellectual Property

 The IETF takes no position regarding the validity or scope of any
 Intellectual Property Rights or other rights that might be claimed to
 pertain to the implementation or use of the technology described in
 this document or the extent to which any license under such rights
 might or might not be available; nor does it represent that it has
 made any independent effort to identify any such rights.  Information
 on the procedures with respect to rights in RFC documents can be
 found in BCP 78 and BCP 79.
 Copies of IPR disclosures made to the IETF Secretariat and any
 assurances of licenses to be made available, or the result of an
 attempt made to obtain a general license or permission for the use of
 such proprietary rights by implementers or users of this
 specification can be obtained from the IETF on-line IPR repository at
 http://www.ietf.org/ipr.
 The IETF invites any interested party to bring to its attention any
 copyrights, patents or patent applications, or other proprietary
 rights that may cover technology that may be required to implement
 this standard.  Please address the information to the IETF at
 ietf-ipr@ietf.org.

Acknowledgement

 Funding for the RFC Editor function is provided by the IETF
 Administrative Support Activity (IASA).

Raftus & Cardona Standards Track [Page 139]

/data/webs/external/dokuwiki/data/pages/rfc/rfc4546.txt · Last modified: 2006/06/23 16:54 by 127.0.0.1