Network Working Group B. Stewart Request for Comments: 1660 Xyplex, Inc. Obsoletes: 1318 July 1994 Category: Standards Track

      Definitions of Managed Objects for Parallel-printer-like
                    Hardware Devices using SMIv2

Status of this Memo

 This document specifies an IAB standards track protocol for the
 Internet community, and requests discussion and suggestions for
 improvements.  Please refer to the current edition of the "IAB
 Official Protocol Standards" for the standardization state and status
 of this protocol.  Distribution of this memo is unlimited.

Table of Contents

 1. Introduction ...............................................    1
 2. The SNMPv2 Network Management Framework ....................    1
 2.1 Object Definitions ........................................    2
 3. Overview ...................................................    2
 3.1 Relationship to Interface MIB .............................    2
 4. Definitions ................................................    3
 5. Acknowledgements ...........................................    9
 6. References .................................................    9
 7. Security Considerations ....................................   10
 8. Author's Address ...........................................   10

1. Introduction

 This memo defines an extension to the Management Information Base
 (MIB) for use with network management protocols in the Internet
 community.  In particular, it defines objects for the management of
 Parallel-printer-like devices.

2. The SNMPv2 Network Management Framework

 The SNMPv2 Network Management Framework consists of four major
 components.  They are:
    o    RFC 1442 [1] which defines the SMI, the mechanisms used for
         describing and naming objects for the purpose of management.
    o    STD 17, RFC 1213 [2] defines MIB-II, the core set of managed
         objects for the Internet suite of protocols.

Stewart [Page 1] RFC 1660 Parallel-printer-like MIB July 1994

    o    RFC 1445 [3] which defines the administrative and other
         architectural aspects of the framework.
    o    RFC 1448 [4] which defines the protocol used for network
         access to managed objects.
 The Framework permits new objects to be defined for the purpose of
 experimentation and evaluation.

2.1. Object Definitions

 Managed objects are accessed via a virtual information store, termed
 the Management Information Base or MIB.  Objects in the MIB are
 defined using the subset of Abstract Syntax Notation One (ASN.1)
 defined in the SMI.  In particular, each object object type is named
 by an OBJECT IDENTIFIER, an administratively assigned name.  The
 object type together with an object instance serves to uniquely
 identify a specific instantiation of the object.  For human
 convenience, we often use a textual string, termed the descriptor, to
 refer to the object type.

3. Overview

 The Parallel-printer-like Hardware Device MIB applies to interface
 ports that would most probably support the Character MIB.  The most
 common example is Centronics-like printer port.
 The Parallel-printer-like Hardware Device MIB is mandatory for all
 systems that have such a hardware port supporting services managed
 through some other MIB.
 The Parallel-printer-like Hardware Port MIB includes Centronics-like
 and Data-Products-like parallel physical links with a similar set of
 control signals.
 The MIB contains objects that relate to physical layer connections.
 The MIB comprises one base object and three tables, detailed in the
 following sections.  The tables contain objects for ports and input
 and output control signals.

3.1. Relationship to Interface MIB

 The Parallel-printer-like MIB is one of many MIBs designed for
 layered use as described in the Interface MIB [5].  In most
 implementations where it is present, it will be in the lowest
 interface sublayer, that is, the Parallel-printer-like MIB represents
 the physical layer, providing service to higher layers such as the

Stewart [Page 2] RFC 1660 Parallel-printer-like MIB July 1994

 Character MIB [6].
 Although it is unlikely that a parallel printer port will actually be
 used as a network interface, which is the intent of the Interface
 MIB, the Parallel-printer-like MIB is closely connected to the
 Character MIB, which can share hardware interfaces with network
 operation, and relate to the RS-232 MIB [7].
 The Interface MIB's ifTestTable and ifRcvAddressTable are not
 relevant to the Parallel-printer-like MIB.
 The Parallel-printer-like MIB is relevant for ifType values para(34)
 and perhaps others.
 The Parallel-printer-like MIB requires the conformance groups
 ifGeneralGroup, and ifFixedLengthGroup.
 Usefulness of error counters in this MIB depends on the octet
 counters in ifFixedLengthGroup.

4. Definitions

 PARALLEL-MIB DEFINITIONS ::= BEGIN
 IMPORTS
     MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
     Counter32, Integer32
         FROM SNMPv2-SMI
     InterfaceIndex
         FROM IF-MIB
     transmission
         FROM RFC1213-MIB
     MODULE-COMPLIANCE, OBJECT-GROUP
         FROM SNMPv2-CONF;
 para MODULE-IDENTITY
      LAST-UPDATED "9405261700Z"
      ORGANIZATION "IETF Character MIB Working Group"
      CONTACT-INFO
             "        Bob Stewart
              Postal: Xyplex, Inc.
                      295 Foster Street
                      Littleton, MA 01460
                 Tel: 508-952-4816
                 Fax: 508-952-4887
              E-mail: rlstewart@eng.xyplex.com"

Stewart [Page 3] RFC 1660 Parallel-printer-like MIB July 1994

      DESCRIPTION
             "The MIB module for Parallel-printer-like hardware devices."
     ::= { transmission 34 }
  1. - Generic Parallel-printer-like information
 paraNumber OBJECT-TYPE
     SYNTAX Integer32
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The number of ports (regardless of their current
         state) in the Parallel-printer-like port table."
     ::= { para 1 }
  1. - the Parallel-printer-like Port table
 paraPortTable OBJECT-TYPE
     SYNTAX SEQUENCE OF ParaPortEntry
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
         "A list of port entries.  The number of entries is
         given by the value of paraNumber."
     ::= { para 2 }
 paraPortEntry OBJECT-TYPE
     SYNTAX ParaPortEntry
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
         "Status and parameter values for a port."
     INDEX { paraPortIndex }
     ::= { paraPortTable 1 }
 ParaPortEntry ::=
     SEQUENCE {
         paraPortIndex
             InterfaceIndex,
         paraPortType
             INTEGER,
         paraPortInSigNumber
             Integer32,
         paraPortOutSigNumber
             Integer32
     }

Stewart [Page 4] RFC 1660 Parallel-printer-like MIB July 1994

 paraPortIndex OBJECT-TYPE
     SYNTAX InterfaceIndex
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The value of ifIndex for the port.  By convention
         and if possible, hardware port numbers map directly
         to external connectors.  The value for each port must
         remain constant at least from one re-initialization
         of the network management agent to the next."
     ::= { paraPortEntry 1 }
 paraPortType OBJECT-TYPE
     SYNTAX INTEGER {
         other(1),
         centronics(2),
         dataproducts(3)
     }
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The port's hardware type."
     ::= { paraPortEntry 2 }
 paraPortInSigNumber OBJECT-TYPE
     SYNTAX Integer32
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The number of input signals for the port in the
         input signal table (paraPortInSigTable).  The table
         contains entries only for those signals the software
         can detect and that are useful to observe."
     ::= { paraPortEntry 3 }
 paraPortOutSigNumber OBJECT-TYPE
     SYNTAX Integer32
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The number of output signals for the port in the
         output signal table (paraPortOutSigTable).  The
         table contains entries only for those signals the
         software can assert and that are useful to observe."
     ::= { paraPortEntry 4 }

Stewart [Page 5] RFC 1660 Parallel-printer-like MIB July 1994

  1. - Parallel-printer-like Input Signal Table
 paraInSigTable OBJECT-TYPE
     SYNTAX SEQUENCE OF ParaInSigEntry
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
         "A list of port input control signal entries."
     ::= { para 3 }
 paraInSigEntry OBJECT-TYPE
     SYNTAX ParaInSigEntry
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
         "Input control signal status for a hardware port."
     INDEX { paraInSigPortIndex, paraInSigName }
     ::= { paraInSigTable 1 }
 ParaInSigEntry ::=
     SEQUENCE {
         paraInSigPortIndex
             InterfaceIndex,
         paraInSigName
             INTEGER,
         paraInSigState
             INTEGER,
         paraInSigChanges
             Counter32
     }
 paraInSigPortIndex OBJECT-TYPE
     SYNTAX InterfaceIndex
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The value of paraPortIndex for the port to which
         this entry belongs."
     ::= { paraInSigEntry 1 }
 paraInSigName OBJECT-TYPE
     SYNTAX INTEGER { power(1), online(2), busy(3),
                      paperout(4), fault(5) }
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "Identification of a hardware signal."
     ::= { paraInSigEntry 2 }

Stewart [Page 6] RFC 1660 Parallel-printer-like MIB July 1994

 paraInSigState OBJECT-TYPE
     SYNTAX INTEGER { none(1), on(2), off(3) }
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The current signal state."
     ::= { paraInSigEntry 3 }
 paraInSigChanges OBJECT-TYPE
     SYNTAX Counter32
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The number of times the signal has changed from
         'on' to 'off' or from 'off' to 'on'."
     ::= { paraInSigEntry 4 }
  1. - Output Signal Table
 paraOutSigTable OBJECT-TYPE
     SYNTAX SEQUENCE OF ParaOutSigEntry
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
         "A list of port output control signal entries."
     ::= { para 4 }
 paraOutSigEntry OBJECT-TYPE
     SYNTAX ParaOutSigEntry
     MAX-ACCESS not-accessible
     STATUS current
     DESCRIPTION
         "Output control signal status for a hardware port."
     INDEX { paraOutSigPortIndex, paraOutSigName }
     ::= { paraOutSigTable 1 }
 ParaOutSigEntry ::=
     SEQUENCE {
         paraOutSigPortIndex
             InterfaceIndex,
         paraOutSigName
             INTEGER,
         paraOutSigState
             INTEGER,
         paraOutSigChanges
             Counter32
     }

Stewart [Page 7] RFC 1660 Parallel-printer-like MIB July 1994

 paraOutSigPortIndex OBJECT-TYPE
     SYNTAX InterfaceIndex
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The value of paraPortIndex for the port to which
         this entry belongs."
     ::= { paraOutSigEntry 1 }
 paraOutSigName OBJECT-TYPE
     SYNTAX INTEGER { power(1), online(2), busy(3),
                      paperout(4), fault(5) }
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "Identification of a hardware signal."
     ::= { paraOutSigEntry 2 }
 paraOutSigState OBJECT-TYPE
     SYNTAX INTEGER { none(1), on(2), off(3) }
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The current signal state."
     ::= { paraOutSigEntry 3 }
 paraOutSigChanges OBJECT-TYPE
     SYNTAX Counter32
     MAX-ACCESS read-only
     STATUS current
     DESCRIPTION
         "The number of times the signal has changed from
         'on' to 'off' or from 'off' to 'on'."
     ::= { paraOutSigEntry 4 }
  1. - conformance information
 paraConformance OBJECT IDENTIFIER ::= { para 5 }
 paraGroups      OBJECT IDENTIFIER ::= { paraConformance 1 }
 paraCompliances OBJECT IDENTIFIER ::= { paraConformance 2 }

Stewart [Page 8] RFC 1660 Parallel-printer-like MIB July 1994

  1. - compliance statements
 paraCompliance MODULE-COMPLIANCE
     STATUS  current
     DESCRIPTION
             "The compliance statement for SNMPv2 entities
             which have Parallel-printer-like hardware
             interfaces."
     MODULE  -- this module
         MANDATORY-GROUPS { paraGroup }
     ::= { paraCompliances 1 }
  1. - units of conformance
 paraGroup    OBJECT-GROUP
     OBJECTS { paraNumber, paraPortIndex, paraPortType,
               paraPortInSigNumber, paraPortOutSigNumber,
               paraInSigPortIndex, paraInSigName,
               paraInSigState, paraInSigChanges,
               paraOutSigPortIndex, paraOutSigName,
               paraOutSigState, paraOutSigChanges }
     STATUS  current
     DESCRIPTION
             "A collection of objects providing information
              applicable to all Parallel-printer-like interfaces."
     ::= { paraGroups 1 }
 END

5. Acknowledgements

 This memo was produced by the IETF Character MIB Working Group.

6. References

 [1] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Structure
     of Management Information for version 2 of the Simple Network
     Management Protocol (SNMPv2)", RFC 1442, SNMP Research,Inc.,
     Hughes LAN Systems, Dover Beach Consulting, Inc., Carnegie Mellon
     University, April 1993.
 [2] McCloghrie, K., and M. Rose, Editors, "Management Information
     Base for Network Management of TCP/IP-based internets: MIB-II",
     STD 17, RFC 1213, Hughes LAN Systems, Performance Systems
     International, March 1991.

Stewart [Page 9] RFC 1660 Parallel-printer-like MIB July 1994

 [3] Galvin, J., and K. McCloghrie, "Administrative Model for version
     2 of the Simple Network Management Protocol (SNMPv2)", RFC 1445,
     Trusted Information Systems, Hughes LAN Systems, April 1993.
 [4] Case, J., McCloghrie, K., Rose, M., and S. Waldbusser, "Protocol
     Operations for version 2 of the Simple Network Management
     Protocol (SNMPv2)", RFC 1448, SNMP Research,Inc., Hughes LAN
     Systems, Dover Beach Consulting, Inc., Carnegie Mellon
     University, April 1993.
 [5] McCloghrie, K., and F. Kastenholz, "Evolution of the Interfaces
     Group of MIB-II", RFC 1573, Hughes LAN Systems, FTP Software,
     January 1994.
 [6] Stewart, B., "Definitions of Managed Objects for Character Stream
     Devices using SMIv2", RFC 1658, Xyplex, Inc., July 1994.
 [7] Stewart, B., "Definitions of Managed Objects for RS-232-like
     Devices using SMIv2", RFC 1659, Xyplex, Inc., July 1994.

7. Security Considerations

 Security issues are not discussed in this memo.

8. Author's Address

 Bob Stewart
 Xyplex, Inc.
 295 Foster Street
 Littleton, MA 01460
 Phone: 508-952-4816
 Fax: 508-952-4887
 EMail: rlstewart@eng.xyplex.com

Stewart [Page 10]

/data/webs/external/dokuwiki/data/pages/rfc/rfc1660.txt · Last modified: 1994/07/19 20:59 by 127.0.0.1

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki