GENWiki

Premier IT Outsourcing and Support Services within the UK

User Tools

Site Tools


rfc:rfc9561



Internet Engineering Task Force (IETF) C. Hellwig, Ed. Request for Comments: 9561 Category: Standards Track C. Lever ISSN: 2070-1721 Oracle

                                                            S. Faibish
                                                        Opendrives.com
                                                              D. Black
                                                     Dell Technologies
                                                            April 2024

Using the Parallel NFS (pNFS) SCSI Layout to Access Non-Volatile Memory

                   Express (NVMe) Storage Devices

Abstract

 This document specifies how to use the Parallel Network File System
 (pNFS) Small Computer System Interface (SCSI) Layout Type to access
 storage devices using the Non-Volatile Memory Express (NVMe) protocol
 family.

Status of This Memo

 This is an Internet Standards Track document.
 This document is a product of the Internet Engineering Task Force
 (IETF).  It represents the consensus of the IETF community.  It has
 received public review and has been approved for publication by the
 Internet Engineering Steering Group (IESG).  Further information on
 Internet Standards is available in Section 2 of RFC 7841.
 Information about the current status of this document, any errata,
 and how to provide feedback on it may be obtained at
 https://www.rfc-editor.org/info/rfc9561.

Copyright Notice

 Copyright (c) 2024 IETF Trust and the persons identified as the
 document authors.  All rights reserved.
 This document is subject to BCP 78 and the IETF Trust's Legal
 Provisions Relating to IETF Documents
 (https://trustee.ietf.org/license-info) in effect on the date of
 publication of this document.  Please review these documents
 carefully, as they describe your rights and restrictions with respect
 to this document.  Code Components extracted from this document must
 include Revised BSD License text as described in Section 4.e of the
 Trust Legal Provisions and are provided without warranty as described
 in the Revised BSD License.

Table of Contents

 1.  Introduction
   1.1.  Requirements Language
   1.2.  General Definitions
   1.3.  Numerical Conventions
 2.  SCSI Layout Mapping to NVMe
   2.1.  Volume Identification
   2.2.  Client Fencing
     2.2.1.  PRs - Key Registration
     2.2.2.  PRs - MDS Registration and Reservation
     2.2.3.  Fencing Action
     2.2.4.  Client Recovery after a Fence Action
   2.3.  Volatile Write Caches
 3.  Security Considerations
 4.  IANA Considerations
 5.  References
   5.1.  Normative References
   5.2.  Informative References
 Acknowledgements
 Authors' Addresses

1. Introduction

 NFSv4.1 [RFC8881] includes a pNFS feature that allows reads and
 writes to be performed by means other than directing read and write
 operations to the server.  Through use of this feature, the server,
 in the role of metadata server, is responsible for managing file and
 directory metadata while separate means are provided to execute reads
 and writes.
 These other means of performing file reads and writes are defined by
 individual mapping types, which often have their own specifications.
 The pNFS Small Computer System Interface (SCSI) layout [RFC8154] is a
 layout type that allows NFS clients to directly perform I/O to block
 storage devices while bypassing the Metadata Server (MDS).  It is
 specified by using concepts from the SCSI protocol family for the
 data path to the storage devices.
 NVM Express (NVMe), or the Non-Volatile Memory Host Controller
 Interface Specification, is a set of specifications to talk to
 storage devices over a number of protocols such as PCI Express
 (PCIe), Fibre Channel (FC), TCP/IP, or Remote Direct Memory Access
 (RDMA) networking.  NVMe is currently the predominantly used protocol
 to access PCIe Solid State Disks (SSDs), and it is increasingly being
 adopted for remote storage access to replace SCSI-based protocols
 such as iSCSI.
 This document defines how NVMe Namespaces using the NVM Command Set
 [NVME-NVM] exported by NVMe Controllers implementing the NVMe Base
 specification [NVME-BASE] are to be used as storage devices using the
 SCSI Layout Type.  The definition is independent of the underlying
 transport used by the NVMe Controller and thus supports Controllers
 implementing a wide variety of transports, including PCIe, RDMA, TCP,
 and FC.
 This document does not amend the existing SCSI layout document.
 Rather, it defines how NVMe Namespaces can be used within the SCSI
 Layout by establishing a mapping of the SCSI constructs used in the
 SCSI layout document to corresponding NVMe constructs.

1.1. Requirements Language

 The key words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
 "SHOULD", "SHOULD NOT", "RECOMMENDED", "NOT RECOMMENDED", "MAY", and
 "OPTIONAL" in this document are to be interpreted as described in
 BCP 14 [RFC2119] [RFC8174] when, and only when, they appear in all
 capitals, as shown here.

1.2. General Definitions

 The following definitions are included to provide context for the
 reader.
 Client:  The "client" is the entity that accesses the NFS server's
    resources.  The client may be an application that contains the
    logic to access the NFS server directly, or it may be part of the
    operating system that provides remote file system services for a
    set of applications.
 Metadata Server (MDS):  The Metadata Server (MDS) is the entity
    responsible for coordinating client access to a set of file
    systems and is identified by a server owner.

1.3. Numerical Conventions

 Numerical values defined in the SCSI specifications (e.g., [SPC5])
 and the NVMe specifications (e.g., [NVME-BASE]) are represented using
 the same conventions as those specifications wherein a 'b' suffix
 denotes a binary (base 2) number (e.g., 110b = 6 decimal) and an 'h'
 suffix denotes a hexadecimal (base 16) number (e.g., 1ch = 28
 decimal).

2. SCSI Layout Mapping to NVMe

 The SCSI layout definition [RFC8154] references only a few SCSI-
 specific concepts directly.  This document provides a mapping from
 these SCSI concepts to NVM Express concepts that are used when using
 the pNFS SCSI layout with NVMe namespaces.

2.1. Volume Identification

 The pNFS SCSI layout uses the Device Identification Vital Product
 Data (VPD) page (page code 83h) from [SPC5] to identify the devices
 used by a layout.  Implementations that use NVMe namespaces as
 storage devices map NVMe namespace identifiers to a subset of the
 identifiers that the Device Identification VPD page supports for SCSI
 logical units.
 To be used as storage devices for the pNFS SCSI layout, NVMe
 namespaces MUST support either the IEEE Extended Unique Identifier
 (EUI64) or Namespace Globally Unique Identifier (NGUID) value
 reported in a Namespace Identification Descriptor, the I/O Command
 Set Independent Identify Namespace data structure, and the Identify
 Namespace data structure, NVM Command Set [NVME-BASE].  If available,
 use of the NGUID value is preferred as it is the larger identifier.
    |  Note: The PS_DESIGNATOR_T10 and PS_DESIGNATOR_NAME have no
    |  equivalent in NVMe and cannot be used to identify NVMe storage
    |  devices.
 The pnfs_scsi_base_volume_info4 structure for an NVMe namespace SHALL
 be constructed as follows:
 1.  The "sbv_code_set" field SHALL be set to PS_CODE_SET_BINARY.
 2.  The "pnfs_scsi_designator_type" field SHALL be set to
     PS_DESIGNATOR_EUI64.
 3.  The "sbv_designator" field SHALL contain either the NGUID or the
     EUI64 identifier for the namespace.  If both NGUID and EUI64
     identifiers are available, then the NGUID identifier SHOULD be
     used as it is the larger identifier.
 RFC 8154 [RFC8154] specifies the "sbv_designator" field as an XDR
 variable length opaque<> (refer to Section 4.10 of RFC 4506
 [RFC4506]).  The length of that XDR opaque<> value (part of its XDR
 representation) indicates which NVMe identifier is present.  That
 length MUST be 16 octets for an NVMe NGUID identifier and MUST be 8
 octets for an NVMe EUI64 identifier.  All other lengths MUST NOT be
 used with an NVMe namespace.

2.2. Client Fencing

 The SCSI layout uses Persistent Reservations (PRs) to provide client
 fencing.  For this to be achieved, both the MDS and the Clients have
 to register a key with the storage device, and the MDS has to create
 a reservation on the storage device.
 The following subsections provide a full mapping of the required
 PERSISTENT RESERVE IN and PERSISTENT RESERVE OUT SCSI commands [SPC5]
 to NVMe commands that MUST be used when using NVMe namespaces as
 storage devices for the pNFS SCSI layout.

2.2.1. PRs - Key Registration

 On NVMe namespaces, reservation keys are registered using the
 Reservation Register command (refer to Section 7.3 of [NVME-BASE])
 with the Reservation Register Action (RREGA) field set to 000b (i.e.,
 Register Reservation Key) and supplying the reservation key in the
 New Reservation Key (NRKEY) field.
 Reservation keys are unregistered using the Reservation Register
 command with the Reservation Register Action (RREGA) field set to
 001b (i.e., Unregister Reservation Key) and supplying the reservation
 key in the Current Reservation Key (CRKEY) field.
 One important difference between SCSI Persistent Reservations and
 NVMe Reservations is that NVMe reservation keys always apply to all
 controllers used by a host (as indicated by the NVMe Host
 Identifier).  This behavior is analogous to setting the ALL_TG_PT bit
 when registering a SCSI Reservation Key, and it is always supported
 by NVMe Reservations, unlike the ALL_TG_PT for which SCSI support is
 inconsistent and cannot be relied upon.  Registering a reservation
 key with a namespace creates an association between a host and a
 namespace.  A host that is a registrant of a namespace may use any
 controller with which that host is associated (i.e., that has the
 same Host Identifier, refer to Section 5.27.1.25 of [NVME-BASE]) to
 access that namespace as a registrant.

2.2.2. PRs - MDS Registration and Reservation

 Before returning a PNFS_SCSI_VOLUME_BASE volume to the client, the
 MDS needs to prepare the volume for fencing using PRs.  This is done
 by registering the reservation generated for the MDS with the device
 (see Section 2.2.1) followed by a Reservation Acquire command (refer
 to Section 7.2 of [NVME-BASE]) with the Reservation Acquire Action
 (RACQA) field set to 000b (i.e., Acquire) and the Reservation Type
 (RTYPE) field set to 4h (i.e., Exclusive Access - Registrants Only
 Reservation).

2.2.3. Fencing Action

 In case of a non-responding client, the MDS fences the client by
 executing a Reservation Acquire command (refer to Section 7.2 of
 [NVME-BASE]), with the Reservation Acquire Action (RACQA) field set
 to 001b (i.e., Preempt) or 010b (i.e., Preempt and Abort), the
 Current Reservation Key (CRKEY) field set to the server's reservation
 key, the Preempt Reservation Key (PRKEY) field set to the reservation
 key associated with the non-responding client, and the Reservation
 Type (RTYPE) field set to 4h (i.e., Exclusive Access - Registrants
 Only Reservation).  The client can distinguish I/O errors due to
 fencing from other errors based on the Reservation Conflict NVMe
 status code.

2.2.4. Client Recovery after a Fence Action

 If an NVMe command issued by the client to the storage device returns
 a non-retryable error (refer to the DNR bit defined in Figure 92 in
 [NVME-BASE]), the client MUST commit all layouts that use the storage
 device through the MDS, return all outstanding layouts for the
 device, forget the device ID, and unregister the reservation key.

2.3. Volatile Write Caches

 For NVMe controllers, a volatile write cache is enabled if bit 0 of
 the Volatile Write Cache (VWC) field in the Identify Controller data
 structure, I/O Command Set Independent (refer to Figure 275 in
 [NVME-BASE]) is set and the Volatile Write Cache Enable (WCE) bit
 (i.e., bit 00) in the Volatile Write Cache Feature (Feature
 Identifier 06h) (refer to Section 5.27.1.4 of [NVME-BASE]) is set.
 If a volatile write cache is enabled on an NVMe namespace used as a
 storage device for the pNFS SCSI layout, the pNFS server (MDS) MUST
 use the NVMe Flush command to flush the volatile write cache to
 stable storage before the LAYOUTCOMMIT operation returns by using the
 Flush command (refer to Section 7.1 of [NVME-BASE]).  The NVMe Flush
 command is the equivalent to the SCSI SYNCHRONIZE CACHE commands.

3. Security Considerations

 NFSv4 clients access NFSv4 metadata servers using the NFSv4 protocol.
 The security considerations generally described in [RFC8881] apply to
 a client's interactions with the metadata server.  However, NFSv4
 clients and servers access NVMe storage devices at a lower layer than
 NFSv4.  NFSv4 and RPC security are not directly applicable to the
 I/Os to data servers using NVMe.  Refer to Sections 2.4.6 (Extents
 Are Permissions) and 4 (Security Considerations) of [RFC8154] for the
 security considerations of direct access to block storage from NFS
 clients.
 pNFS with an NVMe layout can be used with NVMe transports (e.g., NVMe
 over PCIe [NVME-PCIE]) that provide essentially no additional
 security functionality.  Or, pNFS may be used with storage protocols
 such as NVMe over TCP [NVME-TCP] that can provide significant
 transport layer security.
 It is the responsibility of those administering and deploying pNFS
 with an NVMe layout to ensure that appropriate protection is deployed
 to that protocol based on the deployment environment as well as the
 nature and sensitivity of the data and storage devices involved.
 When using IP-based storage protocols such as NVMe over TCP, data
 confidentiality and integrity SHOULD be provided for traffic between
 pNFS clients and NVMe storage devices by using a secure communication
 protocol such as Transport Layer Security (TLS) [RFC8446].  For NVMe
 over TCP, TLS SHOULD be used as described in [NVME-TCP] to protect
 traffic between pNFS clients and NVMe namespaces used as storage
 devices.
 A secure communication protocol might not be needed for pNFS with
 NVMe layouts in environments where physical and/or logical security
 measures (e.g., air gaps, isolated VLANs) provide effective access
 control commensurate with the sensitivity and value of the storage
 devices and data involved (e.g., public website contents may be
 significantly less sensitive than a database containing personal
 identifying information, passwords, and other authentication
 credentials).
 Physical security is a common means for protocols not based on IP.
 In environments where the security requirements for the storage
 protocol cannot be met, pNFS with an NVMe layout SHOULD NOT be
 deployed.
 When security is available for the data server storage protocol, it
 is generally at a different granularity and with a different notion
 of identity than NFSv4 (e.g., NFSv4 controls user access to files,
 and NVMe controls initiator access to volumes).  As with pNFS with
 the block layout type [RFC5663], the pNFS client is responsible for
 enforcing appropriate correspondences between these security layers.
 In environments where the security requirements are such that client-
 side protection from access to storage outside of the layout is not
 sufficient, pNFS with a SCSI layout on a NVMe namespace SHOULD NOT be
 deployed.
 As with other block-oriented pNFS layout types, the metadata server
 is able to fence off a client's access to the data on an NVMe
 namespace used as a storage device.  If a metadata server revokes a
 layout, the client's access MUST be terminated at the storage devices
 via fencing as specified in Section 2.2.  The client has a subsequent
 opportunity to acquire a new layout.

4. IANA Considerations

 This document has no IANA actions.

5. References

5.1. Normative References

 [NVME-BASE]
            NVM Express, Inc., "NVM Express Base Specification",
            Revision 2.0d, January 2024, <https://nvmexpress.org/wp-
            content/uploads/NVM-Express-Base-Specification-2.0d-
            2024.01.11-Ratified.pdf>.
 [NVME-NVM] NVM Express, Inc., "NVM Express NVM Command Set
            Specification", Revision 1.0d, December 2023,
            <https://nvmexpress.org/wp-content/uploads/NVM-Express-
            NVM-Command-Set-Specification-1.0d-
            2023.12.28-Ratified.pdf>.
 [NVME-TCP] NVM Express, Inc., "NVM Express TCP Transport
            Specification", Revision 1.0d, December 2023,
            <https://nvmexpress.org/wp-content/uploads/NVM-Express-
            TCP-Transport-Specification-1.0d-2023.12.27-Ratified.pdf>.
 [RFC2119]  Bradner, S., "Key words for use in RFCs to Indicate
            Requirement Levels", BCP 14, RFC 2119,
            DOI 10.17487/RFC2119, March 1997,
            <https://www.rfc-editor.org/info/rfc2119>.
 [RFC4506]  Eisler, M., Ed., "XDR: External Data Representation
            Standard", STD 67, RFC 4506, DOI 10.17487/RFC4506, May
            2006, <https://www.rfc-editor.org/info/rfc4506>.
 [RFC5663]  Black, D., Fridella, S., and J. Glasgow, "Parallel NFS
            (pNFS) Block/Volume Layout", RFC 5663,
            DOI 10.17487/RFC5663, January 2010,
            <https://www.rfc-editor.org/info/rfc5663>.
 [RFC8154]  Hellwig, C., "Parallel NFS (pNFS) Small Computer System
            Interface (SCSI) Layout", RFC 8154, DOI 10.17487/RFC8154,
            May 2017, <https://www.rfc-editor.org/info/rfc8154>.
 [RFC8174]  Leiba, B., "Ambiguity of Uppercase vs Lowercase in RFC
            2119 Key Words", BCP 14, RFC 8174, DOI 10.17487/RFC8174,
            May 2017, <https://www.rfc-editor.org/info/rfc8174>.
 [RFC8446]  Rescorla, E., "The Transport Layer Security (TLS) Protocol
            Version 1.3", RFC 8446, DOI 10.17487/RFC8446, August 2018,
            <https://www.rfc-editor.org/info/rfc8446>.
 [RFC8881]  Noveck, D., Ed. and C. Lever, "Network File System (NFS)
            Version 4 Minor Version 1 Protocol", RFC 8881,
            DOI 10.17487/RFC8881, August 2020,
            <https://www.rfc-editor.org/info/rfc8881>.
 [SPC5]     INCITS Technical Committee T10, "SCSI Primary Commands - 5
            (SPC-5)", INCITS 502-2019, 2019.

5.2. Informative References

 [NVME-PCIE]
            NVM Express, Inc., "NVMe over PCIe Transport
            Specification", Revision 1.0d, December 2023,
            <https://nvmexpress.org/wp-content/uploads/NVM-Express-
            PCIe-Transport-Specification-1.0d-
            2023.12.27-Ratified.pdf>.

Acknowledgements

 Carsten Bormann converted an earlier RFCXML v2 source for this
 document to a markdown source format.
 David Noveck provided ample feedback to various drafts of this
 document.

Authors' Addresses

 Christoph Hellwig (editor)
 Email: hch@lst.de
 Charles Lever
 Oracle Corporation
 United States of America
 Email: chuck.lever@oracle.com
 Sorin Faibish
 Opendrives.com
 11 Selwyn Road
 Newton, MA 02461
 United States of America
 Phone: +1 617-510-0422
 Email: s.faibish@opendrives.com
 David L. Black
 Dell Technologies
 176 South Street
 Hopkinton, MA 01748
 United States of America
 Email: david.black@dell.com
/home/gen.uk/domains/wiki.gen.uk/public_html/data/pages/rfc/rfc9561.txt · Last modified: 2024/04/03 21:11 by 127.0.0.1