           A Practical Guide to RS-232 Interfacing
                     Lawrence E. Hughes
                     Mycroft Labs, Inc.
                        P.O. Box 6045
                    Tallahassee, FL 32301
 The  following information is intended to collect together  in

one place, and explain in relatively simple terms, enough of the details of the RS-232 standard to allow a technician to construct and/or debug interfaces between any two "RS-232 Compatible" devices. A more detailed coverage of the subject may be found in the book "Technical Aspects of Data Communication" by John E. McNamara (1977, Digital Press).

 This  guide  is necessary due to the casual way  that  vendors

implement "RS-232" interfaces, sometimes omitting required signals, requiring optional ones, or worse, implementing signals incorrectly. Due to this, and a lack of readily available information about the real EIA standard, there is often considerable confusion involved in trying to interface two RS-232 devices.

                         BACKGROUND
 RS-232-C  is the most recent version of the  EIA  (Electronics

Industry Association) standard for low speed serial data communication. It defines a number of parameters concerning voltage levels, loading characteristics and timing relationships. The actual connectors which are almost universally used (DB-25P and DB-25S, sometimes called "EIA connectors") are recommended, but not mandatory. Typical practice requires mounting the female (DB-25S) connector on the chassis of communication equipment, and male (DB-25P) connectors on the cable connecting two such devices.

 There are two main classes of RS-232 devices, namely DTE (Data

Terminal Equipment), such as terminals, and DCE (Data Communication Equipment), such as modems. Typically, one only interfaces a DTE to a DCE, as opposed to one DTE to another DTE, or one DCE to another DCE, although there are ways to do the later two by building non-standard cables. Rarely if ever are more than two devices involved in a given interface (multidrop is not supported). A serial port on a computer may be implemented as either DTE or DCE, depending on what type of device it is intended to support.

 RS-232  is  intended for relatively short (50 feet  or  less),

relatively low speed (19,200 bits per second or less) serial (as opposed to parallel) communications. Both asynchronous and synchronous serial encoding are supported. As 'digital' signals (switched D.C. voltage, such as square waves) are used, as opposed to 'analog' signals (continuously varying voltage, such as sine waves) a very wide bandwidth channel (such as direct wire) is required. A limited bandwidth channel (such as a phone circuit) would cause severe and unacceptable distortion and consequent loss of information.

 RS-232 will support simplex,  half-duplex, or full-duplex type

channels. In a simplex channel, data will only ever be travelling in one direction, e.g. from DCE to DTE. An example might be a 'Receive Only' printer. In a half-duplex channel, data may travel in either direction, but at any given time data will only be travelling in one direction, and the line must be 'turned around' before data can travel in the other direction. An example might be a Bell 201 style modem. In a full-duplex channel, data may travel in both directions simultaneously. An example might be a Bell 103 style modem. Certain of the RS-232 'hand-shaking' lines are used to resolve problems associated with these modes, such as which direction data may travel at any given instant.

 If  one  of the devices involved in an RS-232 interface  is  a

real modem (especially a half-duplex modem), the 'hand-shaking' lines must be supported, and the timing relationships between them are quite important. These lines are typically much easier to deal with if no modems are involved. In certain cases, these lines may be used to allow one device (which is receiving data at a higher rate than it is capable of processing indefinitely) to cause the other device to pause while the first one 'catches up'. This use of the hand-shaking lines was not really intended by the designers of the RS-232 standard, but it is a useful by-product of the way such interfaces are typically implemented.

 Much  of  the  RS-232 standard is concerned  with  support  of

'modems'. These are devices which can convert a serial digital data signal into an analog signal compatible with a narrow bandwidth (e.g. 3 kHz) channel such as a switched telephone circuit, and back into serial digital data on the other end. The first process is called 'MOdulation', and the second process is called 'DEModulation', hence the term 'MODEM'. The actual process used (at data rates of up to 1200 bits per second) is FSK (Frequency Shift Keying), in which a constant frequency sine wave (called the 'carrier') is shifted to a slightly higher or slightly lower frequency to represent a logic 0 or logic 1, respectively. In a half duplex modem, the entire available bandwidth is used for one direction. In a full duplex modem, the available bandwidth is divided into two sub-bands, hence there is both an 'originate carrier' (e.g. for data from the terminal to the computer), and an 'answer carrier' (e.g. for data from the computer to the terminal). The actual frequencies (in Hertz) used on the Bell 103A full duplex modem are:

   signal    state   Originate  Answer
   logic 0   SPACE     1180      1850
   carrier             1080      1750
   logic 1   MARK       980      1650

.pa

         THE STANDARD CIRCUITS AND THEIR DEFINITIONS
 For  the  purposes  of the RS-232  standard,  a  'circuit'  is

defined to be a continuous wire from one device to the other. There are 25 circuits in the full specification, less than half of which are at all likely to be found in a given interface. In the simplest case, a full-duplex interface may be implemented with as few as 3 circuits. There is a certain amount of confusion associated with the names of these circuits, partly because there are three different naming conventions (common name, EIA circuit name, and CCITT circuit name). The table below lists all three names, along with the circuit number (which is also the connector pin with which that circuit is normally associated on both ends). Note that the signal names are from the viewpoint of the DTE (e.g. Transmit Data is data being sent by the DTE, but received by the DCE).

   PIN  NAME EIA  CCITT  DTE  DCE     FUNCTION
    1    CG   AA   101     ---        Chassis Ground
    2    TD   BA   103     -->        Transmit Data
    3    RD   BB   104     <--        Receive Data
    4    RTS  CA   105     -->        Request To Send
    5    CTS  CB   106     <--        Clear To Send
    6    DSR  CC   107     <--        Data Set Ready
    7    SG   AB   102     ---        Signal Ground
    8    DCD  CF   109     <--        Data Carrier Detect
    9*                     <--        Pos. Test Voltage
   10*                     <--        Neg. Test Voltage
   11                                 (usually not used)
   12+   SCDC SCF  122     <--        Sec. Data Car. Detect
   13+   SCTS SCB  121     <--        Sec. Clear To Send
   14+   STD  SBA  118     -->        Sec. Transmit Data
   15#   TC   DB   114     <--        Transmit Clock
   16+   SRD  SBB  119     <--        Sec. Receive Data
   17#   RC   DD   115     <--        Receive Clock
   18                                 (not usally used)
   19+   SRTS SCA  120     -->        Sec. Request To Send
   20    DTR  CD   108.2   -->        Data Terminal Ready
   21*   SQ   CG   110     <--        Signal Quality
   22    RI   CE   125     <--        Ring Indicator
   23*        CH   111     -->        Data Rate Selector
              CI   112     <--        Data Rate Selector
   24*   XTC  DA   113     -->        Ext. Transmit Clock
   25*                     -->        Busy
 In the above, the character following the pin number means:
  • rarely used

+ used only if secondary channel implemented

   #    used only on synchronous interfaces

also, the direction of the arrow indicates which end (DTE or DCE) originates each signal, except for the ground lines (—). For example, circuit 2 (TD) is originated by the DTE, and received by the DCE. Certain of the above circuits (11, 14, 16, and 18) are used only by (or in a different way by) Bell 208A modems.

 A  secondary channel is sometimes used to provide a very  slow

(5 to 10 bits per second) path for return information (such as ACK or NAK characters) on a primarily half duplex channel. If the modem used suppports this feature, it is possible for the receiver to accept or reject a message without having to 'turn the line around', a process that usally takes 100 to 200 milliseconds.

 On  the above circuits,  all voltages are with respect to  the

Signal Ground (SG) line. The following conventions are used:

   Voltage        Signal    Logic     Control
   +3 to +25      SPACE       0          On
   -3 to -25      MARK        1          Off

Note that the voltage values are inverted from the logic values (e.g. the more positive logic value corresponds to the more negative voltage). Note also that a logic 0 corresponds to the signal name being 'true' (e.g. if the DTR line is at logic 0, that is, in the +3 to +25 voltage range, then the Data Terminal IS Ready).

         ELECTRICAL CHARACTERISTICS OF EACH CIRCUIT
 The following criteria apply to the electrical characteristics

of each of the above lines:

1) The magnitude of an open circuit voltage shall not exceed 25V.

2) The driver shall be able to sustain a short to any other wire in the cable without damage to itself or to the other equipment, and the short circuit current shall not exceed 0.5 ampere.

3) Signals shall be considered in the MARK (logic 1) state when the voltage is more negative than -3V with respect to the Signal Ground. Signals shall be considered in the SPACE (logic 0) state when the voltage is more positive that 3V with respect to the Signal Ground. The range between -3V and 3V is defined as the transition region, within which the signal state is not defined.

4) The load impedance shall have a DC resistance of less than 7000 ohms when measured with an applied voltage of from 3V to 25V but more than 3000 ohms when measured with a voltage of less than 25V.

5) When the terminator load resistance meets the requirements of Rule 4 above, and the terminator open circuit voltage is 0V, the magnitude of the potential of that circuit with respect to Signal Ground will be in the 5V to 15V range.

6) The driver shall assert a voltage between -5V and -15V relative to the signal ground to represent a MARK signal condition. The driver shall assert a voltage between 5V and 15V relative to the Signal Ground to represent a SPACE signal condition. Note that this rule in conjunction with Rule 3 above allows for 2V of noise margin. Note also that in practice, -12V and 12V are typically used.

7) The driver shall change the output voltage at a rate not exceeding 30 volts per microsecond, but the time required for the signal to pass through the -3V to +3V transition region shall not exceed 1 millisecond, or 4 percent of a bit time, whichever is smaller.

8) The shunt capacitance of the terminator shall not exceed 2500 picofarads, including the capacitance of the cable. Note that when using standard cable with 40 to 50 picofarads per foot capacitance, this limits the cable length to no more than 50 feet. Lower capacitance cable allows longer runs.

9) The impedance of the driver circuit under power-off conditions shall be greater than 300 ohms.

 Note that two widely available integrated circuit chips  (1488

and 1489) implement TTL to RS232 drivers (4 per chip), and RS232 receivers to TTL (also 4 per chip), in a manner consistent with all of the above rules.

           DEFINITION OF THE MOST COMMON CIRCUITS

1 CG Chassis Ground

   This  circuit  (also called Frame Ground) is a mechanism  to
   insure  that the chassis of the two devices are at the  same
   potential, to prevent electrical shock to the operator. Note
   that  this circuit is not used as the reference for  any  of
   the other voltages. This circuit is optional. If it is used,
   care should be taken to not set up ground loops.

2 TD Transmit Data

   This  circuit is the path whereby serial data is  sent  from
   the DTE to the DCE.  This circuit must be present if data is
   to travel in that direction at any time.

3 RD Receive Data

   This  circuit  is the path whereby serial data is sent  from
   the DCE to the DTE.  This circuit must be present if data is
   to travel in that direction at any time.

4 RTS Request To Send

   This  circuit  is  the signal that indicates  that  the  DTE
   wishes  to  send data to the DCE (note that no such line  is
   available  for the opposite direction,  hence the  DTE  must
   always be ready to accept data).  In normal  operation,  the
   RTS  line  will be OFF (logic 1 / MARK).  Once the  DTE  has
   data  to  send,  and has determined that the channel is  not
   busy,  it will set RTS to ON (logic 0 / SPACE), and await an
   ON condition on CTS from the DCE,  at which time it may then
   begin  sending.  Once the DTE is through  sending,  it  will
   reset  RTS  to  OFF (logic 1 / MARK).  On a  full-duplex  or
   simplex  channel,  this  signal  may be set to  ON  once  at
   initialization and left in that state.  Note that some  DCEs
   must  have  an incoming RTS in order to  transmit  (although
   this  is  not strictly according to the standard).  In  this
   case,  this  signal must either be brought across  from  the
   DTE,  or provided by a wraparound (e.g. from DSR) locally at
   the DCE end of the cable.

5 CTS Clear To Send

   This  circuit is the signal that indicates that the  DCE  is
   ready to accept data from the DTE.  In normal operation, the
   CTS line will be in the OFF state. When the DTE asserts RTS,
   the  DCE  will do whatever is necessary to allow data to  be
   sent (e.g.  a modem would raise carrier,  and wait until  it
   stabilized).  At this time,  the DCE would set CTS to the ON
   state, which would then allow the DTE to send data. When the
   RTS from the DTE returns to the OFF state,  the DCE releases
   the channel (e.g.  a modem would drop carrier), and then set
   CTS back to the OFF state. Note that a typical DTE must have
   an  incoming CTS before it can transmit.  This  signal  must
   either  be  brought  over from the DCE,  or  provided  by  a
   wraparound  (e.g.  from  DTR) locally at the DTE end of  the
   cable.

6 DSR Data Set Ready

   This circuit is the signal that informs the DTE that the DCE
   is alive and well. It is normally set to the ON state by the
   DCE  upon power-up and left there.  Note that a typical  DTE
   must  have  an incoming DSR in order to  function  normally.
   This  line  must either be brought over  from  the  DCE,  or
   provided by a wraparound (e.g.  from DTR) locally at the DTE
   end  of  the cable.  On the DCE end of the  interface,  this
   signal  is almost always present,  and may be  wrapped  back
   around (to DTR and/or RTS) to satisfy required signals whose
   normal function is not required.

7 SG Signal Ground

   This  circuit is the ground to which all other voltages  are
   relative. It must be present in any RS-232 interface.

8 DCD Data Carrier Detect

   This  circuit is the signal whereby the DCE informs the  DTE
   that it has an incoming carrier.  It may be used by the  DTE
   to  determine  if the channel is idle,  so that the DTE  can
   request  it  with  RTS.  Note that some DTEs  must  have  an
   incoming DCD before they will operate.  In this  case,  this
   signal must either be brought over from the DCE, or provided
   locally  by a wraparound (e.g.  from DTR) locally at the DTE
   end of the cable.

15 TC Transmit Clock

   This circuit provides the clock for the transmitter  section
   of  a synchronous DTE.  It may or may not be running at  the
   same  rate  as  the receiver clock.  This  circuit  must  be
   present on synchronous interfaces.

17 RC Receiver Clock

   This  circuit provides the clock for the receiver section of
   a synchronous DTE.  It may of may not be running at the same
   rate as the transmitter clock.  Note that both TC and RC are
   sourced  by  the  DCE.  This  circuit  must  be  present  on
   synchronous interfaces.

20 DTR Data Terminal Ready

   This  circuit provides the signal that informs the DCE  that
   the  DTE  is alive and well.  It is normally set to  the  ON
   state  by the DTE at power-up and left there.  Note  that  a
   typical  DCE  must  have  an incoming  DTR  before  it  will
   function  normally.  This signal must either be brought over
   from the DTE,  or provided by a wraparound (e.g.  from  DSR)
   locally at the DCE end of the cable.  On the DTE side of the
   interface,  this signal is almost always present, and may be
   wrapped back around to other circuits (e.g.  DSR, CTS and/or
   DCD)  to  satisfy  required hand-shaking  signals  if  their
   normal function is not required.
 Note that in an asynchronous channel,  both ends provide their

own internal timing, which (as long as they are within 5% of each other) is sufficient for them to agree when the bits occur within a single character. In this case, no timing information need be sent over the interface between the two devices. In a synchronous channel, however, both ends must agree when the bits occur over possibly thousands of characters. In this case, both devices must use the same clocks. Note that the transmitter and receiver may be running at different rates. Note also that BOTH clocks are provided by the DCE. When one has a synchronous terminal tied into a synchronous port on a computer via two synchronous modems, for example, and the terminal is transmitting, the terminal's modem supplies the Transmit Clock, which is brought directly out to the terminal at its end, and encodes the clock with the data, sends it to the computer's modem, which recovers the clock and brings it out as the Receive Clock to the computer. When the computer is transmitting, the same thing happens in the other direction. Hence, whichever modem is transmitting must supply the clock for that direction, but on each end, the DCE device supplies both clocks to the DTE device.

 All  of the above applies to interfacing a DTE device to a DCE

device. In order to interface two DTE devices, it is usually sufficient to provide a 'flipped' cable, in which the pairs (TD, RD), (RTS,CTS) and (DTR,DSR) have been flipped. Hence, the TD of one DTE is connected to the RD of the other DTE, and vica versa. It may be necessary to wrap various of the hand-shaking lines back around from the DTR on each end in order to have both ends work. In a similar manner, two DCE devices can be interfaced to each other.

 An  RS-232  'break-out box' is particularly useful in  solving

interfacing problems. This is a device which is inserted between the DTE and DCE. Firstly, it allows you to monitor the state of the various hand-shaking lines (light on = signal ON / logic 0), and watch the serial data flicker on TD and/or RD. Secondly, it allows you to break the connection on one or more of the lines (with dip-switches), and make any kind of cross-connections and/or wraparounds (with jumper wires). Using this, it is fairly easy to determine which line(s) are not functioning as required, and quickly build a prototype of a cable that will serve to interface the two devices. At this point, the break-out box can be removed and a real cable built that performs the same function. An example of this kind of device is the International Data Sciences, Inc. Model 60 'Modem and Terminal Interface Pocket Analyzer' (also called a 'bluebox'). Care should be taken with this type of device to connect the correct end of it to the DTE device, or the lights and switches do not correspond to the actual signals.